Professional Documents
Culture Documents
Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.
EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.
FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability
CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)
Unidirectional Bidirectional
MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump
Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated
COMBINATION CONTROLS
LINES MEASUREMENT
Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow
Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
UENR5901
July 2014
Quick Coupler
Note: Check Part Number In The Part Manual For Your Specific Machine.
Note A: Refer To Parts Manual For Your Specific Machine.
TAP TABLE
Tap Locations
Pressure, Sampling, and Sensor
Tap Schematic
Description
Number Location
AA Pilot Pump Delivery Pressure B-3
BB Idler Pump Delivery Pressure A-3
CC Drive Pump Delivery Pressure A-5
DD Drive Pump Power Shift Pressure B-2
EE Idler Pump Power Shift Pressure A-2
FF Case Drain Pressure A-2
SOS Oil Sampling Port A-4
8 7 6 5 4 3 2 1
MA MB MB MA
(28) VALVE GP
SWING CUSHION
322-8716
AR4 BR4
A B B A
(29) VALVE GP
A(R) B(L)
TRAVEL (30) VALVE GP
E COUNTERBALANCE (LH)
E
TRAVEL
BL2 AL2 322-8714 COUNTERBALANCE (RH)
322-8714
(24) VALVE GP BL1 AL1 BR1 AR1
PILOT (TRAVEL) TP (FWD) (BKWD) (BKWD)
(FWD)
369-8502
TT (16) SWIVEL GP (18) VALVE GP
SWG
MOTOR 234-4440 LOAD CONTROL
TRAVEL(L) TRAVEL(R) (19) VALVE GP DRAIN QC-T (BOOM)
LOAD CONTROL (STICK) 255-5683
255-5680
DRAIN 2 SPEED
BR5 SDr BL3 AL3 FILTER TRAVEL AL4 BDr BR4 BR5 AR5
CONTROL
SPi
R.C.V-A aL4 AL2 AL1 Di4 Pi4 BR1 AR1 BR3 aR4 R.C.V-B
aL1 bL1 bR1 aR1
D aL3 BL2 BL1 aR1 aR3 aR5
D
T SP1 ST aR2 BR2 AR2 Pi1 BP1 BT R3
5 6 3 2 (UP) BL3 R2 (IN) (L) (BKWD) (BKWD) (CLOSE) (DOWN) BR4 R1 (IN)
4 1 (20) VALVE GP
PD-Dr
MAIN CONTROL
PD-Pi 259-7380
4 1
5 6 3 2
JLT JRT
STICK SWING BUCKET BOOM
BOOM(2)
ATCH
BUCKET
SWING
TRAVEL(R)
BOOM(1)
STICK(2)
TRAVEL(L)
STICK(1)
UENR5901
B1 B2 B3 B4 C B5 B6 B7 B8
PRESSURE (11) PUMP GP
Pi4 MF-P Di4 PD-Pi bR4-2 REDUCING BB PISTON (MAIN)
(BOOM,SWING 422-1294
A1 B2 A2 G2
aR3 aR4 bR3 bR4 bL3 bL2 bL4 aL2 B1 PRIORITY)
PD-Dr Di3 310-0210 M2 LINE PATTERNS
B B
P2 P-IN Pressure Line
Pi1 PSA2 DR1 PSA1 DST
Pilot / Load Sensing Pressure
Pn2
T-OUT2 DR2 PL HL Drain / Return Lines
(SWING)
NO.2
CALLOUTS
CHECK (OIL 164-6981
NO.3
R.C.V-C
COOLER BYPASS) Pi2 PRV-P2 S3 YY Taps (Pressure, Sampling, Sensor - by letter)
R.C.V-B
173-4672 DL DL D Connectors (By letter)
C
B PRV-P2 (6) FILTER GP S1 Dr Callout Number Component
P1 OIL
(Machine Location from (52) VALVE GP - CONTROL Name
PG PC M1
(7) FILTER GP THIS SCHEMATIC IS FOR THE 326D2 AND 329D2 EXCAVATOR HYDRAULIC SYSTEM
A3 G1 Pm
OIL (PILOT) ATTACHMENT: QUICK COUPLER
158-8987 AA SOS
(13) SENSOR AS -
PRESSURE
CC MEDIA NUMBER: UENR5901
(DRIVE) SCHEMATIC PART NUMBER: 344-4217, CHANGE: 01, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off, with parking brake set.
434-3436 Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
8 7 6 5 4 3 2 1
PUMP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS
CC DD BB 6 5
EE
AA
SOS
13 11 15 FF
MAIN VALVE - VIEW FROM REAR
VIEW ALL CALLOUTS
14 20 12
17
18
19
25
26
NOT
SHOWN
23 1
MACHINE - RIGHT REAR VIEW
VIEW ALL CALLOUTS
2 4
3
16
28
8
31
29
30
10
CAB - TOP VIEW
VIEW ALL CALLOUTS
24
21 27 22