180 Testing techniques

I I , 1 I
10 20 30 40 i 50
10 20 30 40 ‘50 60
L
20
I
30 40
I I
50 Bo .a
20 30 40 50 80 v
Schmidt hammer (type L)rebound number

Broch &Franklin (1972)


0
D’Andrea el al. (1965)
x
+Bieniawski (1974)
Strong
norite
X
a

0 50 I00 150 200 250 300 350


Uniaxial compressive strength ucfMN/m2
Figure 11.6 Schmidt hammer and point load test calibration curves.