Technical Datasheet

7/06/2021

Model: THK1340YCF

Product Description
Type: Reciprocating Compressors
Application: LBP - Low Back Pressure
ProductDescription: R-134a
Voltage/Frequency: 230V ~ 50Hz
Version: N/A

Product Specifications
Performance

Ref rigeration Capacity Input Power (E) Ef f iciency


(R) (R) (R) (E) (E) EVAP AMBIENT RETURN LIQUID
Condition Test Voltage Btu/h kcal/h W (I) W Btu/Wh kcal/Wh W/W TEMP Condition TEMP GAS TEMP
ASHRAE 230V ~ 50HZ 365 92 107 94 3.88 .98 1.13 - 23°C ( - 10°F) 54°C ( 130°F) 32°C ( 90°F) 32°C ( 90°F) 32°C ( 90°F)

General

Evaporating Temp. Range: -34.4°C to -12.2°C (-30°F to 10°F)


Motor Torque: Low Start Torque (LST)
Compressor Cooling: Static

Mechanical

Weight: 7
Weight Unit of Measure: KG
Displacement (cc): 4
Oil Type: Polyolester
Viscosity (cSt): 22
Oil Charge (cc): 210

Electrical

Voltage Range (50 Hz): 160-260


Voltage Range (60 Hz):
Locked Rotor Amps (LRA): 8.1
Rated Load Amps (RLA 50 Hz): .8
Rated Load Amps (RLA 60 Hz): 0
Max. Continuous Current (MCC in Amps): 1.28
Motor Resistance (Ohm) - Main: 24.7
Motor Resistance (Ohm) - Start: 29.5
MotorType: PTCS_IR
Overload Type:
Relay Type:

Agency Approval

CE Listed
Performance Data Sheet
THK1340YCF

General
Model THK1340YCF Unit of Measure Fahrenheit
Condition ASHRAE Voltage/Frequency 230V ~ 50HZ
RETURN GAS 32.2°C (90°F) RETURN GAS MotorType PTCS_IR

COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW


C1 1.323828E+03 -3.082127E+02 6.431682E-01 -1.002848E+01
C2 2.883349E+01 -1.906266E+00 -1.749218E-04 3.540203E-01
C3 -1.667727E+01 1.009982E+01 1.546627E-03 4.688167E-01
C4 1.518995E-01 -2.834020E-02 2.008983E-05 3.310220E-03
C5 -1.995064E-01 4.946681E-02 3.534717E-05 -2.244158E-03
C6 1.247567E-01 -8.316267E-02 -3.389770E-06 -4.145452E-03
C7 -5.980325E-04 -6.927068E-04 1.113929E-06 -2.609412E-07
C8 -2.535514E-04 9.060731E-05 1.564723E-07 -1.427270E-05
C9 6.875057E-04 -1.831402E-04 -1.144718E-07 7.067329E-06
C10 -3.557133E-04 2.341258E-04 7.350719E-09 1.146667E-05

Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3

Te = Evaporator Temperature
Tc = Condensing Temperature