You are on page 1of 1

125'

FFRB10

FFRB11

FFRB11
S1

FFRB1
FFRB10

S3 S3

FFRB7
NO SLAB NO SLAB
FFRB3

FFRB2
FFRB10 FFRB4

FFRB2

FFRB2

FFRB1
S1
S1
S3
50'

FFRB3 FFRB3 FFRB4

FFRB1

FFRB1
FFRB2

FFRB1
S3 S1 S1

FFRB4

FFRB3 FFRB10

ROAD

SCHEDULE OF FIFTH FLOOR ROOF BEAM SCHEDULE OF SLAB ( FIFTH FLOOR ROOF SLAB DETAILS)

DIMENSIONS REINFORCEMENT STIRRUPS REINFORCEMENT CONCRETE


SLAB RATIO
S.NO. MARKED BOTTOM EXTRA TOP EXTRA END MIDDLE EXTRA AT SUPPORT ON TOP
B D S.NO. MARKED ALONG REMARKS (CEMENT/
BARS AT BOT. BARS AT TOP STIRRUPS STIRRUPS THK ALONG
SHORT SPAN ALONG ALONG SAND/
LONG SPAN
1. FFRB1 12" 30" 5 - 25 T - 7 - 25 T - 10T - 4" C/C 10T - 4" C/C SHORT SPAN LONG SPAN AGGREGATE)

2. FFRB2 12" 30" 5 - 25 T - 7 - 25 T 3 - 25 T 10T - 4" C/C 10T - 4" C/C 1. S1 5" 10 T - 6"C/C 8 T - 8"C/C - - ONE WAY 1:1.5:3
3. FFRB3 12" 24" 3 - 20 T 3 - 20 T 3 - 20 T 3 - 20 T 8T - 4" C/C 8T - 4" C/C
2. S2 5" 8 T - 6"C/C 8 T - 8"C/C - - ONE WAY 1:1.5:3
4. FFRB4 12" 24" 3 - 20 T 2 - 20 T 3 - 20 T 2 - 20 T 8T - 4" C/C 8T - 4" C/C

5. FFRB5 8" 24" 3 - 16 T 2 - 16 T 3 - 16 T 2 - 16 T 8T - 4" C/C 8T - 4" C/C


3. S3 6" 10 T - 4"C/C 10 T - 6"C/C 10 T - 8"C/C 10 T - 12"C/C TWO WAY 1:1.5:3
6. FFRB6 8" 5" 2 - 12 T - 2 - 12 T - 8T - 6" C/C 8T - 6" C/C

7. FFRB7 8" 20" 3 - 12 T - 3 - 12 T - 8T - 4" C/C 8T - 6" C/C

8. FFRB8 3 - 16 T - 3 - 16 T - 8T - 4" C/C 8T - 4" C/C


12" 5"
NOT FOR EXECUTION
9. FFRB9 8" 5 - 16 T - 5 - 16 T - 10T - 4" C/C 10T - 4" C/C
16"
ONLY FOR STUDY
10. FFRB10 8" 20" 2 - 16 T 2 - 16 T 2 - 16 T 2 - 16 T 8T - 4" C/C 8T - 6" C/C

11. FFRB11 8" 20" 4 - 25 T - 6 - 25 T - 8T - 4" C/C 8T - 4" C/C FIFTH FLOOR ROOF BEAM PLAN
NOTE:- ISSUE OF PRINTS
S.NO. DATE ISSUED TO PROJECT:- MAHESH ATITHI NIWAS DRN & DLT BY. SCALE
W
1) THIS DRAWING IS THE PROPERTY OF "ANKUR & SARVESH (ARCHITECTURE|INTERIOR)"
AND CANNOT BE USED OR REPRODUCED IN ANY FORM WITHOUT THEIR APEKSHA N.T.S.
WRITTEN PERMISSION S N
APPROVED. BY DATE Website : www.ankursarvesh.com
2) ALL DIMENSIONS ARE IN METERS/FEET UNLESS SPECIFIED. E
ANKUR 15-10-2019 E-mail : studio@ankursarvesh.com
3) DO NOT SCALE THE DRAWINGS ONLY WRITTEN DIMENSIONS ARE
Contact : 77479-00000(A), 77729-22222(S), 0731-4060020(O)
TO BE FOLLOWED.
JOB NO. DRG. NO Address : 104-105 Bansiwala Tower, Agresen Square, Indore.
4) THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH DRG.NO-------