Professional Documents
Culture Documents
EcoStruxure Power Advisor - Training
EcoStruxure Power Advisor - Training
“I do it myself. I
am an expert :
make it easy to
Edge EcoStruxure Power Management analyze data
Control (PSO +AR, PME, Energy Expert) myself”
** Facility Expert, Facility Advisor are positioned to the Small & Medium Building market, so they are not on this chart.
Complexity
▪ Generation from single to multi source, PV, Wind, CoGen etc. 80% of power management systems have
outdated configurations that put monitoring
▪ Drive for cost reduction, VSD’s, LED’s and other Eco measures and control of the network at risk
▪ System visibility can be limited, and expertise to manage scarce
10-15% of devices in the typical power
management system are nearing end of
their supported lifecycle
Criticality
▪ Efficient use of energy can have significant impacts on budgets
▪ Asset longevity is affected by power quality Many hours of non-productive on site
maintenance activity can be needed to
▪ Poor power quality can increase risks to personnel and property investigate the system and identify issues
• Overvoltage - Based on industry standards from your area, voltage measurements above
allowed threshold reported. Standard chosen according to country on ‘settings’ tab.
• Under voltage - As above, voltage measurements below allowed threshold reported.
• Voltage Imbalance - Based on industry standard practices, one or more phases reporting voltage
imbalance outside allowed tolerance.
• Excessive Harmonic Distortion – Sustained voltage distortion in excess of 3%
• Transformer Overcapacity - Transformer(s) loaded above rated capacity.
• No Data in Query Period – same as Meter Diagnostics
• Device not in Hierarchy – same as Meter Diagnostics
Isolated Meter
•Device not in hierarchy
•Unchanging Value
•Negative Values Present
Energy Balance
•Consistently Negative Values •Energy Balance Violation
•Irregular Device Logging Periods •Meter Underreporting or Overreporting Consumption
•Meter Detection Threshold Too High
•Misplaced Meter
Configuration
Meter Family
•Mismatched consumption
measurements
•Mismatched logging intervals
– Brochure
– Video
– Sample reports
• EcoStruxure Power analytics / services layer includes Power Advisor digital service plans
• Produces END USER reports Identifying irregularities % affected for System, to prioritize on maintenance
actions and Information on Electrical network issues leading to PQ Mitigation solution pull through
• Transformation to Digitized service offer providing efficiency, productivity and highly valued services
• Low Cost, Easy & Fast to deploy Cloud based solution, PA data extraction then upload to cloud