Professional Documents
Culture Documents
Power Solutions
Contents 1 Discover the Offer
2 Value Proposition
3 Applications
4 System Architecture
5 Demo
2X
faster growth of electricity
10X
more connected devices
82%
of untapped energy efficiency
70%
of new capacity additions
demand compared to than people by 2025 potential in buildings will be renewable forms
energy demand by 2040 (and more than 50% by 2040
in industry)
Source: IEA WEO 2014 Source: United Nations, IHS Source: World Energy Outlook 2012 Source: BNEF
How power distribution has changed
Energy
efficiency
Distributed generation
Growing complexity in the model has its challenges
Infrastructure Buildings
Gain and Edge on your Competition
Power Monitoring Expert brings edge control to power distribution
Apps, Analytics
Safe Reliable
& Services
Power Advisor
Protect Optimize
People and Business
PME
Assets continuity
Edge Control
Efficient Compliant
IP Communications Backbone
Maximize Simplify
Connected Lifecycle Regulatory
Products Power Protective RTUs, Breakers,
Meters Relays PLCs Trip
FD
Breakers,
Variable UPSs PQ
Water, Efficiency Compliance
Speed Air,
Sensors, Correction
Units, Drives Gas,
Gateways Gateways Steam
Take full control of your power.
Power Monitoring Expert maximizes your power reliability and operational efficiency.
PME (Power Monitoring Expert) helps the facilities team in large and power critical facilities
analyze, troubleshoot, and make informed decisions about their electrical distribution systems.
It automatically collects data from your facility’s electrical network and presents it as
meaningful, actionable information via intuitive web interface.
Make informed decisions to maintain power reliability and a Run and efficient and compliant facility
safe installation Analyze energy performance with the ISO50001 program
Run power events analysis thanks to default/rich data support, energy modeling, energy intensity KPIs, plus usage
integration for connected devices (e.g. Masterpact MTZ circuit by equipment type and state.
breaker, ION9000, PM8000, AccuSine), events time-
sequence, location, and power quality waveform analysis.
Track your facility’s power quality performance and
compliance against standards
SAFE RELIABLE
Protect People & Assets Optimize Business Continuity
• Avoid electrical fires • Avoid disruption of business by preventing failure of
• Prevent electrical shock and ensure protection Electrical Distribution
• Recover from an outage and restore power safely • Increase Electrical Asset & System Reliability and
Lifetime
EFFICIENT
Maximize Operational & Deployment COMPLIANT
Maximize Lifecycle Efficiency Simplify Regulatory Compliance
• Save money in design & deployment • Demonstrate commitment to sustainability
• Save money by reducing energy spend • Maintain compliance obligations
• Save money by optimizing maintenance
Insulation Monitoring Power Event Analysis Cost Allocation Power Quality Compliance
“I want to prevent electrical fires in my facility and have a solution to detect abnormal temperature rises in my conductors. This
is important at both the MV and LV level.”
“I want to remotely view the status of the Isolated Power in my operating rooms and intensive care units, and in case of any
insulation fault, I want to know the location of the fault.”
Customer
ConfidentialUse
PropertyCase
of Schneider Electric Digital Architecture
Breaker Settings Monitoring
“I want to continuously monitor breaker trip settings, analyze and compare breaker trip curves, audit breaker trip setting changes
and alert when breaker discrimination is lost.”
Customer use
Confidential caseof Schneider Electric
Property Digital Architecture
Power Events Analysis
“I want to understand the root cause and impact of cascading and chronic power system events and use this information to
reconstruct events, respond appropriately and determine cause to prevent in the future.”
Airport Case
Confidential Property Study
of Schneider Electric Hospital Case Study
Power Quality Monitoring
“I want to have the information to identify power quality issues and manage their impact to keep them from disrupting operations
or damaging my critical loads and equipment.”
“I want to prevent disruption to business from electrical overload with load management and capacity planning.”
“I want to ensure uptime during an electrical outage and have peace of mind that I can rely on my backup power supply when it is needed.”
Hospital applications
Configuration & Commissioning Efficiency
“I want to save money by reducing the amount of time it takes to configure & commission my MV LV Smart panels and integrate
the EcoStruxure Power power management software.”
“I want to verify that my utility bill is accurate, both from a metering and bill calculation perspective.”
“I want to encourage energy efficient behaviour and support cost accounting by accurately allocating direct and
indirect energy costs to departments / processes.”
“I want to compare the efficiency of energy use across buildings / plants / process lines.
Industry case
Confidential study
Property of Schneider Electric 30
Energy Usage Analysis
“I want to analyze how much energy is consumed by the various load types and/or areas in my facility to determine
where to focus my energy conservation initiatives.”
“I want to analyse the energy performance of my facility or building against a modeled baseline which takes into
account relevant energy drivers.”
Industry caseProperty
Confidential studyof Schneider Electric 32
Save Money by reducing
Energy Performance Verification Energy Spend
“I want to verify the energy savings from an energy retrofit or energy savings program.”
“I want to benchmark my energy consumption with respect to a national or international energy efficiency
certifications body and display our energy reduction success to the public.”
“I want to track and report carbon emissions for public disclosure/transparency, green image, regulatory compliance,
or participation in carbon markets.”
“I want to help ensure that my facility’s systems are aligned with our organization’s cyber security policies and align
with international standards to help reduce risk of cyber attacks.”
SM6
MV Gear MV Gear
ION9000 Vamp Easergy T300
(Meter) (Arc Flash) (Switch Control
Sepam
Radial & ATS)
Micom PS100
(Protection Relay) (Aux Supply)
Transfo. MV/LV (Trial)
Low Voltage
Power Monitoring
Link 150
MLVS Gear MLVS Gear eIFE / IFE Expert with Power Advisor
PM5000 Digital Services
PM8000
iPCC Okken / Blokset NSX PLC or VARLogic
NT / NW / MTZ 3rd Party (ATS) ReactiVAR
Final Distribution
Local
UPS HMI
Galaxy / Smart UPS Modbus TCP
Floor IT Isolated Acti9 Power Tag
Smart Panel Smart Panel Smart Panel Dual Contactor
LCD2
Operating Room NSX
Patient Room Data Center
Intensive Care Prisma / Blokset ieM3000 IM20-H HRP Display
PME Architecture
Simple and Centralized
Server: Thick Clients: Thin Clients:
Application + Database Engineering Tools Main User Interface (Web based)
IP Backbone
Modbus …
and ION
Protocols
Power Protection Breakers, RTUs,
Meters Relays Trip Variable
PLCs
Units, Speed
UPSs Drives Water,
Gateways Air,
Gas,
PQ Steam
Correction
Equipment Final
Distribution
Breakers,
Sensors,
Confidential Property of Schneider Electric | Page 39 Gateways
PME is Integration Ready
Open and Interoperable
3rd party
Ethernet
Bacnet
Automation Lon
Servers Modbus Other
ION
Modbus
Customer data
1. Review all of the data obtained Resolution Path is extract occurs to
negotiated with the
on the customer system for customer
gather data
Act
Review Power Advisor Review
Review
2. Identify problem points
generated by the report