You are on page 1of 2

PT.

Waskita Niagaprima

Jl. Angsana Raya Blok A5-1A Delta Silicon


Lippo Cikarang, Bekasi
Phone 021- 8972731 / 32
Fax : 021 89903346

REPAIR REPORT PNUMATIC PNEUMATIC VALVE TURBIN HP

Client : PJB UBJOM PLTU INDRAMAYU PO#: YL0983.SP/612/UBJOMIN/2021 Project ID:

Attn. : Date: 12 August 2021 Job No: -

INTRODUCTION
The purpose of this report is to provide information related to Repair of Pneumatic Valve Turbine HP

VALVE REPAIR

1. Repair Activity
Following repair activity for Pneumatic Valve Turbine HP as below,

Valve Data :
No Valve Tag No. Brand Model Serial No. Size / CLASS
1 N/A Unknown N/A N/A DN 50 / 2500 BW

Pic 1. Pneumatic Valve Turbine HP after dismantle

Typical Welded Type One Piece Body Ball Valve


PT. Waskita Niagaprima

Jl. Angsana Raya Blok A5-1A Delta Silicon


Lippo Cikarang, Bekasi
Phone 021- 8972731 / 32
Fax : 021 89903346

Pneumatic Valve Turbine HP


ITEM FOUNDING
BALL Dimension Ball Valve
OD1 : 32.7 mm
OD2 : 26.6 mm
ID : 16 mm

SEAT
Dimension Seat
OD : 33.6 mm
ID : 16.25 mm
Thickness : 8.3 mm

Note after Dismantle :


- The Ball founded steam cut on the surface need to built up or replace
- The Seat founded steam cut on surface
- Body valve Folk Pneumatic Valve Turbine HP is solid
Because of damage cause by steam cut the minimum critical dimension cannot be
established even by lapping.

Recomendation Note :
- Seat, if needed replace new Ball.
- Lapping Ball, if needed replace new Ball.