Professional Documents
Culture Documents
THIS DRAWING IS THE SOLE PROPERTY OF ' KALA-AKAAR & ASSOCIATES '
AND IS NOT TO BE COPIED OR USED WITHOUT PRIOR PERMISSION.
5500 ALL DIMENSIONS SHALL BE CO-RELATED WITH STRUCTURAL AND SERVICE DRAWINGS
AND ANY AMBIGUITY SHALL BE IMMEDIATELY BROUGHT TO THE NOTICE OF THE
ARCHITECT BEFORE THE COMMENCEMENT OF WORK.
5000
250
THIS DRAWING SHALL SUPERSEDE ITS PREVIOUS REVISIONS.
250
ALL "L" BENDS SHALL BE "LD"OR 300 MM WHICH EVER IS
HIGHER (UNLESS NOTED OTHERWISE) FOR FOOTING.
300
NOMINAL COVER TO MAIN REINFORCEMENT SHALL BE AS
FOLLOWS BUT NOT LESS THAN THE DIA OF MAIN BARS -
MAIN HOLE RAFT - 50 MM; BEAMS - 25 MM; WALL - 30MM; & SLAB - 20 MM;
.600X.450 2NOS 10MM
USE CONCRETE MIX M : 20 HAVING CHARACTERISTIC
R.C.C. UNDER GROUND
3000
3500
COMPRESSIVE STRENGTH OF 20 N/SQMM AS PER IS 456 - 2000 AS PER TENDER
WATER TANK
CAPACITY - 30000 LIT, DETAIL OF MAIN HOLE
250 250 USE CONCRETE MIX M : 15 FOR PCC HAVINGCHARACTERISTIC COMPRESSIVE
STRENGTH OF 15 N/SQMM AS PER IS 456 - 2000. AS PER TENDER.
A OVER FLOW
INLET PIPE
A USE STEEL COLD TWISTED BAR .
PIPE
250
PLAN OF WATER TANK
300
20MM SQUARE BAR STEPS 20MM SQUARE BAR STEPS
750
MAXIMUM WATER. LVL @ 300MM C/C STAGGERED FREE BOARD @ 300MM C/C STAGGERED MAXIMUM WATER. LVL
300
N.G.L. N.G.L.
2200
1900
1900
8MM @ 200MM C/C
12MM @ 175MM C/C
250
12MM @ 175MM C/C
10MM @ 200MM C/C 10MM @ 200MM C/C
8MM @ 200MM C/C
900 10MM @ 200MM C/C RAFT - 300MM THICK 900
BOTH WAY
600 600 BOTTOM LEVEL
300
PROJECT:
L PTS BIKANER .RAJASTHAN