You are on page 1of 1

2215 NOTES

20 70
40 1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE MENTIONED.
PRE-CAST PRE-CAST PRE-TENSIONED 40 2. DIMENSIONS ARE NOT TO BE SCALED,ONLY WRITTEN DIMENSIONS SHELL BE FOLLOWED
PRE-TENSIONED 1 PLANKS 2135X300X50 3. SAFE BEARING CAPACITY AT FOUNDING IS 10.0L/M².
POST (M-35) 4. CONCRETE SHELL BE DESIGN MIX A MINIMUM CHARACTERISTIC STRENGTH OF 35MPo.
5. LOCATION OF BOUNDARY WALL SHALL BE KEPT AS PER CLAUSE 2.28 OF SCHEDULE C, I.e. RCC
BOUNDARY WALL SHALL BE PROVIDED ALONG THE ENTIRE LENGTH OF EITHER
2 SIDE(INCLUDING TRANSVERSE REQUIREMENT @STRUCTURE LOCATIONS .THIS DRAWING TO
BE READ IN CONJUNCTION WITH P&P AND STRUCTURE GAD DRAWING FOR SETTING LAYOUT
PLAN OF BOUNDARY WALL.
A A

1500
PRESTRESSING DETAIL
3
1. ULTIMATE BREAKING STRENGTH OF SINGLE PLAN WIRE OF 4MM IS 2.6 TONNE.
2. STRAND SHALL BE STRESSED UPTO 50 % OF ULTIMATE BREAKING STRENGTH IN SUCH A MANNER

1900
THAT STRAND WILL REMAIN STRAIGHT .
(GRADE 3. TATA WIRON OR EQUIVALENT MANUFACTURE AS APPROVED BY AUTHORITY ENGINEER MAY BE USED.
4

2250
OF CONCRETE 4. ELONGATION AT PRESTRESSING END IS 10.2MM.AREA OF 4MM HT WIRE =12.57 MM², ES=1.95X10 5
M-35) N/MM². IF THERE IS CHANGE IN THE PROPERTIES OF THE WIRE. THE ELONGATION MUST BE
EVALUATED BASED ON THE MATERIAL AVAILABLE AS SITE.
5. IS 1343 LATEST REVISION TO BE USED FOR PRESTRESSING WORK.
5
607.5 1000 607.5
G.L G.L
150
70 65 50 40 70 40

400
P.C.C M15 P.C.C M15 10X10
42.5
40
750

700 ø CIRCULAR FOOTING 70 50


50 65
350

350
D D D D 5
185 50
65
5 42.5
700 700 60 7 NOS. 4MM THK.
F2 (FOR EVERY 8TH P.C/H.T WIRE
F1 50 50
FOUNDATION) 50 60 60
TYPICAL DETAIL OF PRE-CAST BOUNDARY WALL SECTION A-A
185 (SCALE-1:5)
700 SECTION A-A
(AT CORNER)
B

50
10X10
2135
150
40 70 40
50 10X10
100 100
300 SECTION D-D 50
100 (SCALE-1:15)
300
50 5 3 NOS. 4MM THK.
P.C/H.T WIRE
50
607.5 607.5 700 ø 100
B

8 NOS. 4MM THK.


3 NOS. 4MM THK. P.C/H.T WIRE
P.C/H.T WIRE 50 50
20
ELEVATION OF PRE-CAST PANEL SECTION A-A 50
(SCALE-1:5)
(AT END) SECTION B-B
SECTION D-D (SCALE-1:5)
(SCALE-1:15) SIZE OF PLANK 2135 X 300 X 50
CLIENT: INDEPENDENT ENGINEER : EPC CONTRACTOR : CONCESSIONAIRE : DESIGN CONSULTANT : PROJECT : DRAWING TITLE :
DRG. NO. CIPL/D1060/HW/DWG/001
Devlopment of Six Lane Hatibena-Badakumari Section
of NH-130-CD Road from km 146+500 to km 179+000 BOUNDARY WALL DATE : NOVEMBER- 2021 REV: R0
under Raipur-Visakhapatnam Economics Corridor in
R0 NOV. 2021 SUBMISSION OF BOUNDARY WALL the State of Odisha on Hybrid Annuity Mode DESIGNED DRAWN CHECKED APPROVED
NATIONAL HIGHWAYS PRA-HATIBENA-BADAKUMARI (Package-OD-2). (Length -32.500 km)
AUTHORITY OF INDIA CIVIL MANTRA INFRACON PVT LTD. RS MM AK SM
REV DATE DESCRIPTION A B C D BARBRIK PROJECT LIMITED. EXPRESSWAY PVT. LTD. SCALE : AS SHOWN PAPER SIZE : A3