15 41. Conductor : Copper 2. Insulation : PVC 3. Sheath : PVC. Cree arent Type: NYY BDS IEC-60502 & VDE-0271/3.69 Voltage: 600/1000 volts Construction Plain annealed Copper Conductor, PVC insulated, PVC sheathed, Single core cable. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts Colour of Sheath: BLACK. Nominal] No.and | Max.DC | Nomin Nominal | Approx ADDTOX. Cross Nominal JResistance of] thickness | thickness of } overall et Sectional | diameter | Conductor ea sheath | diameter ‘Area of | of Wires | at 20°C | insulation aie con Bend eed ixiSre | Y/138 124 ix1Sim —7/0.52 1a 08 1x25re | YL78 741 09 1x251m — 7/0.67 7a 09 ix4rm 7/085 461 10 18 83 43 47 39 1x6rm ——7/1.05 3.08 1.0 18 88 140 59 50 1x10 7/135 1.83 10 18 98 190 7 69 Axt6im 7/171 1.45 10 18 10.8 262 100 94 1x16rm —19/1.04 1.5 10 18 110 268 100 4 1x2sim 7/244 0.727 12 18 12.6 375 130 125 1x251m 19/130 0.727 12 18 128 385 130 125 1x351m 19/153 0.524 12 18 139 482 155 160 1x50rm 19/183 0.387 14 18 158 60 185, 195 1x70rm 19/217 0.268. 14 18 178 870 225 245 41x951m 192.52 0.193 16 18 20.0 1145 270 300 1x1201m 37/203 0.453 16 18 216 1400 310 350 1x1501m —37/2.27 0.124 18 18 23.7 1735 350 405 1x1851m 377252 0.0991 20 20 263 2130 330 460 1x2401m 61/224 0.0754 22 20 29.3, 2735 450 555 1x3001m 61/250 ‘0.0601 24 20 32.2 3342 515 640 1x400"m —61/2.89 (0.0470 26 22 36.0 4430 585 7 1x5001m — 61/3.23 (0.0366 30 22 403 500 680 900 1x630rm 127/252 (0.0283, 30 22 42 6810 800 1030 1x8001m 127/284 (0.0221 3.0 24 49.1 8520 945 1160 1x 1000%m — 127/317 0.0176 30 28 540 10500 1095 1310 Ensure Quality Product 16 Type: NYY 4. Conductor: Copper BDS IEC-60502 & VDE-0271/3.69 2. Insulation: PVC Voltage: 600/1000 volts 3. Common Covering PVC 4, Sheath : PVC, Construction Plain Annealed Copper Conductor, PVC Insulated, Cores laid up, PVC common covering & PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath: BLACK. Nominal | No.and | Max. Dc Nominal | Approx ord 55 Nominal J Resistance of thickness of | overall iT sectional | diameter | Conductor sheath | diameter cone ‘Area of | of Wires penis cain 2xi5re 1/138 18 2x15rm — 7/0.52 18 2x25re —/L78 s 18 2x251m 7/067 r 18 2x40rm — 7/085 . 18 2x6.0rm —7/1.05 18 2xtom = 7/1.35 1.83 10 18 18.1 550 4 2 2x16m = 7/2.72 1.45 10 18 20.2 720 97 a4 2x251m 7/214 on7 12 18 245 1050 125 10 2x351m —19/1.53 0.524 12 20 274 1350 150 140 3x1Sre 1/138 124 08 18 12a 200 2 16 3x15em 7/052 124 os 18 125 210 2 16 3x25re 178 at 9 18 135 266 30 2B 3x251m 7/067 741 09 18 14.0 278 30 2B 3x40rm ——7/0.85 461 10 18 158 376 38 32 3x6.0rm —7/1.05 3.08, 10 18 170 465 48 at 3x10Mm = 7/2.35 1.83 10 18 19.0 650 64 56 Bx16rm 21.7 145 1.0 18 219 900 83 5 3x251m —-7/2.14 or 12 20 25.8 1360 110 98 3x35sm — Min6 wire 0.524 12 18 23.5 1440 130 120 3x50sm — Min6 wire 0.387 14 2.0 270 2000 155 150 3x70sm Min i2wire 0,268 14 20 30.0 2600 190 190 3x95sm Min 15 wire 0.193, 16 20 345 3850 225 230 3x120sm Min 18 wire 0.153 16 22 a7, 4300 260 270 3x150sm Min 18 wire 0.124 18 22 410 5300 295 305 3x185sm Min 30 wire 0.0991 20 22 45 6460 330 350 3x240sm —Min34wire 0.0754 22 26 50.5 8380 385 410 3x300sm —Min34 wire 0.0601 24 26 55.2 10350 425 470 & Ensure Quality Product v7 4. Conductor: Copper BDS IEC-60502 & VDE-0271/3.69 poorer c) 2. Insulation : PVC 3. Common Covering : PVC 4, Sheath: PVC Voltage: 600/1000 volts Construction Contd.) Poo Nominal | No. and | Max.0C | Nominal | Nominal | Approx rod Nominal Resistance of| thickness } thickness | overall | weight of diameter | Conductor of of cut co Ground ‘Area of | of Wires | at20'C | Insulation | sheath Petia corr enn om 3x25rm/ 7/214 0.727 1x16rm ——-7/4.71 145 10 3x35sm/ Min6wire 0.524 12 20. 272 1740 130 120 1x16 7/74 1.45 10 3x50sm/ Minéwire 0.387 14 20 295 2360 155 150 1x251m 7/214 on7 12 3x70sm/ Min i2wire 0,268 14 20 348 3330 190 190 1x351m 19/153 0.524 12 3x95sm/ Min i5wire 0.193 16 22 38.8 4500 225 230 1x501m — 19/1.83 0.387 14 3x120sm/ Min 18 wire 0.153 16 22 as 5400 260 270 1x70rm = 19/2.17 0.268 14 3x150sm/ Min 18 wire 0.124 18 26 46.0 6200 295 305 1x70rm — 19/2.17 0.268 14 3x185sm/ Min 30 wire 0.0991 20 26 51.0 7800 330 350 1x951m 19/252 0.193 16 3x240sm/ Min34wire 0.0754 22 3.0 S70 9850 385 410 1x1201m 37/203 0.153 16 3x300sm/ Min34wire 0.0601, 24 3.0 4 12500 025, 470 1x1501m 37/227 0.124 18 Ensure Quality Product 18 Type: NYY 41, Conductor: Copper Standard: BDS IEC-60502 & VDE-0271/3.69 poorer) 2 Insulation : PVC 3. Common Covering : PVC 4, Sheath : PVC Voltage: 600/1000 volts Construction ¢ Contd.) Nominal Max.0¢ | Nomi Nominal | Approx nd Cross yminal_ | Resistance cy overall TA Sectional | diameter of ea Ci Cron ‘Area of | of Wires | Conductor | insulation aie Belial 4xisre 1/138 124 08 18 13.0 255 2 4x15m 7/052 14 os 18 B3 260 2 16 4x25re 1/178 741 09 18 145 330 30 2B 4x25m 7/067 744 a9 18 148 360 30 2B 4x4im 7/0.85 461 10 18 70 460 38 32 4x64m 711.05 3.08 10 18 18.4 600 48 au 4x10m = 7/1.35 1.83 10 18 20.6 820 «4 56 4x16m 7/74 145 10 18 240 1150 83 B 4x25mm 7/214 0727 12 20 28.5 1730 110 98 4x35sm — Min6wire 0,524 12 20. m2 1950 130 120 4x50sm — Min6 wire 0,387 14 20 29.8 2620 155 150 4x70sm Min 12 wire 0.268 14 20 35.2 3460 190 390 4x95sm Min iS wire 0,193 16 22 393 4800 2s 230 4x120sm Min 18 wire 0.153 16 22 42.0 5700 260 270 4x150sm Min 18 wire 0.124 18 26 465 7080 295 305 4x185sm Min 30 wire 90,0991, 20 26 Sid 8640 330 350 4x240sm —Min34wire 0.0754 22 3.0 58.0 11300 385 410 4x300sm Min 34wire 0.0601, 24 3.0 642 13760 425 470 Ensure Quality Product 19 Type: NYY-1 4. Conductor: Copper Standard: BDS IEC-60502 and VDE-0271/3.69 2 Insulation: PVC Voltage: 600/1000 volts 3. Coman Covering PVC tape 4. Sheath: PVC Construction Plain Annealed Copper Conductor, PVC Insulated, Cores laid up, PVC common covering & PVC sheathed overall. Suitable for use as control cables, in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath: BLACK. Table: 10 Nominal Cross] No. and [Maximum J Nomi Ce a pameyed resistance of| thickness | thickness | overall tot [argon of Conductor | _clameter ry ee ens ES eae Insulation | — sheath Cees 7x15 te 41.38 124 os 18 BS 258 16 2 WOxLSre 1/138 124. 08 18 170 365 B 10 12x15 re 11.38 124 og 18 75 420 2 9 16x15 re 11.38 124 os 18 19.2 540 uw 8 19x15re 1/138 121 08 18 20.1 610 40 7 2x LSre 41.38 124 os 18 aa 660 9 7 xis 1/138 121, 08 20 23.0 750 9 7 30x15 re 41.38 14 og 2.0 245 900 8 6 5x251e 4.78 744 09 18 44 300 2 19 7x25 41.78 241 09 18 15.4 375 a v7 10x25 re 4.78 744 09 18 19.4 520 18 4 12x25re “4.78 741 09 18 19.7 590 16 3 16x25re 1/1.78 741 09 18 27 750 “4 ul 19x25 re 4.78 741 09 18 2.8 880 B 10 x2Sre ——/A.78 741 09 20 245 960 B 10 24x25 re 1.78 744 09 20 270 1100 2 9 30x25re 1/1.78 741 09 20 285 1310 40 8 Sx4em 7/0.85 461 10 18 2 30 31 25 7x40m 710.85 461 10 18 18.4 540 7 2 10x 41m 710.85 461 10 18 Ba 750 2B 19 12x 41m 710.85 461 10 20 243 880 a v7 EE 20 Type: NYCY +. Conductor: Copper ‘Standard: BDS IEC-60502 & VDE-0271/3.69 DT ee eau ee 2. Insulation : PVC Voltage: 600/1000 volts 3. Common Covering : PVC. 4, Concentric Neutral : Copper 5. Sheath : PVC Construction Plain annealed Copper Conductor, PVC Insulated, Three cores laid up, PVC common covering, Concentric neutral or protective conductor of annealed copper over common covering and & PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath: BLACK. SEVICETy Nominal | No.and | Max.Dc | Nominal | Nominal | Approx rod lor Rael thickness | overall et under Sectional | ciameter : a diameter co on ren Cas a Penna ovine 3x251m/ 7/214 0727 1x16C 72/054 145 3x35sm/ Min6wire 0,524 12 20 248 1560 130 120 1x16C 72/054 14s 3x50sm/ Minéwire 0.387 14 20 29.0 2200 155 150 1x25C 50/08 727 3x70sm/ Min 12 wire 0.268, 14 20 314 2920 190 190 1x35C 70/08 0.524 3x95sm/ Min 15 wire 0.193 16 22 36.9 3970 225 230 1x50C 59/105 0.387 3x120sm/ Min 18 wire 0.153, 16 22 39.8 4925 260 20 1x70€ 7/113 0.268 3x150sm/ Min 18 wire 0,124 18 22 432 5910 295 305 1x70C 7/113 0.268 3x185sm/ Min30wire 0.0991 20 26 478 7370 330 350 1x95 67/135 0.193 3x240sm/ Min 34wire 0.0754 22 26 534 9500 385 410 1x120C 67/153 0.153, 3x300sm —Min34 wire 0.0601 24 3.0 58.7 11700 425 470 1x150C 72/163 0.124 RBeco. SEU 2 Type: NYFGbY Standard: BDS IEC-60502 & VDE-0271/3.69 Voltage: 600/1000 volts 4, Conductor : Copper 2. Insulation : PVC. 3. Common Covering : PVC 4, Armour : Flat GalvStee! wire with Steel tape binder 5. Oversheath : PVC. Construction Plain annealed Copper Conductor, PVC Insulated, Three, Three & Half or Four cores laid up, PVC common covering, Flat aly. Stee! Wires armouring with helical steel tape binder & PVC sheathed overall Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath: BLACK. erry Max.DC | Nomi Ce rr Resistance of| thickness | thickness | overall a diameter} Conductor of of Ceara ae 20°C | Insulation | sheath Bara TILT 145 7/214 on 12 20 28.0 1890 3x35sm — Min6wire 0.524 12 20 26.2 1950 130 120 3x50sm — Min6wire 0.387, 14 20 29.0 2500, 155 150 3x70sm Min 12 wire 0.268 14 20 318 3100 190 190 3x95sm Min 15 wire 0.193, 16 22 370 4250 25 230 3x120sm Min 18 wire 0.153 16 22 39.8 5160 260 270 3x150sm Min 1Bwire 0.124 18 22 32 6250 295 305 3x185sm — Min30 wire 0.0991, 20 26 474 7660 330 350 3x240sm Min 34 wire 0.0754 22 26 52.8 9600 385 410 3x300sm — Min34wire 0.0601, 24 3.0 58.2 11850 425 470 Ensure Quality Product 22 Type: NYFGbY 4. Conductor : Copper Standard: BDS IEC-60502 & VDE-0271/3.69 pererenner roar 2. Insulation : PVE 7 3. Common Covering : PVC Voltage: 600/1000 volts 4. Armour : Flat Gaiv Steel wita with Stoel tape binder 5, Oversheath : PVC. Construction Contd.) PrCEe) Nominal | No.and | Max.0c | Nominal | Nominal | Approx rod lor Rael Ci thickness | overall et under Sectional | ciameter of diameter co on ‘Area of | of Wires | at20:C | Insulation | sheath Penna ovine 3x25rm/ 7/214 0727 Axi6rm 7/171 145 10 3x35sm/ — Min6wire 0.524 12 20 20.4 2250 130 120 xterm 7/471 145 10 3x50sm/ — Min6 wire 0.387 14 20 316 2950 155 150 1x25 1m 7/234 0.727 12 3x70sm/ Min 2wire 0.268 14 22 373 3930 190 190 1x351m 19/153 0.524 12 3x95sm/ Min 5 wire 0.193 16 22 a4 5100 225 230 ix50rm 19/183 0.387 14 3x120sm/ Min 18 wire 0.153, 16 22 44.0 6320 260 20 1x701m 19/217 0.268 14 3x150sm/ Min 18 wire 0.124 18 26 488 7380 295 305 ix70rm 19/217 0.268 14 3x185sm/ Min 30wire 0.0991 20 26 555 9250 330 350 1x951m 19/252 0.193 16 3x240sm/ —Min34 wire 0.0754 22 3.0 632 11600 383 410 1x120m 37/203 0.153, 16 3x300sm — Min34 wire 0.0601 24 3.0 70.2 13800 425 470 ixisom 37/227 0.124 18 Type: NYFGbY Standard: BDS IEC-60502 & VDE-0271/3.69 Voltage: 600/1000 volts Construction ¢ Table : 14, re Co cory fearing 4x16 rm 4x25 rm 4x35 5m 4x50sm 4x70sm 4x95 5m 4x120sm 4x 150 sm 4x 185 sm 4x240sm 4x 300 sm Contd.) Ces eas TILT 7/214 Min 6 wire Min 6 wire Min 12 wire Min 15 wire Min 18 wire Min 18 wire Min 30 wire Min 34 wire Min 34 wire ee Conductor Bend on7 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 a thickness ea pet 12 12 14 14 16 16 18 20 22 24 od Coe ca ero 20 2.0 29 22 22 22 26 26 3.0 34 ‘Approx ot Cron 305 29.5 33.0 38.0 420 446 49.2 55.2 633 69.8 Ee nad 4260 5400 8200 9950 12600 15400 1. Conductor : Copper 2. Insulation - PVC 3. Common Covering : PVC 4, Armour : Flat Galv Steel wire with steel tape binder 5, Oversheath : PVC 110 130 155 190 25 260 295 330 385 425 ThA 120 150 190 270 305 350 410 470 24 Type: NYFGbY 4. Conductor; Copper " - Insulation BDS TEC-60502 & VDE-0271/3.69 Gero ee ec ene eeing : PVG 4, Armour : Flat Galv Steel wire with stee! tape binder 5. Oversheath : PVC Plain annealed Copper Conductor, PVC Insulated, Three cores laid up, PVC common covering, PVC common covering, Flat Galv. steel wire armour with helical steel tape binder & PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 4200/7200 volts. Colour of sheath : RED roe EB Max.DC Nomi Nominal ] Approx rs oo Resistance of| thickness | thickness | overall TA Sectional | diameter | Conductor of of Ceara ‘Area of | of Wires | at20%¢ | insulation | sheath aie mm 7/2344 Min 6 wire 0.524 34 22 39.0 3300 3x50sm — Minéwire 0.387 34 22 42.0 4150 3x70sm Min 2wire 0.268 34 26 455 5230 3x95sm_ Min 5 wire 0.193 34 26 49.0 6080 215 25 3x120sm Min 18 wire 0.153, 34 26 52.0 7150 245 270 3x150sm Min 18 wire 0.124 34 26 54.0 8250 25 305 3x185sm Min30wire 0.0991 34 3.0 59.5 10000 305 350 3x240sm Min 34 wire 0.0754 34 3.0 6.8 12000 350 405, 3x300sm Min34wire 0.0601, 34 34 70.0 15500 390 460 Ensure Quality Product 25 Type: NYSY 1. Conductor : Copper ‘Standard: BDS IEC-60502 & VDE-0271/3.69 Coe eneg 2. Insulation : PVC Voltage: 3500/6000 volts 3. Common Covering : PVC 4, Metalic Shild : Cooper 5. Sheath : PVC Construction Plain annealed Copper Conductor, PVC Insulated, Single core/three cores laid up, PVC common covering (for three core), Metallic shield by copper and PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 4200/7200 volts. Colour of sheath : RED cee Nominal | No. and Nominal | Nominal | Approx | Approx Co Nominal Resistance off thickness } thickness | overall | weightot [Under Sectional | diameter | Conductor Ry of diameter | cable Ground ‘area of | of Wi Insulation at 30°C co o.xmm?nojmm hr 1x25 7/244 1x35 19/1.53 1x50 19/1.83 18 203 885 183 180 1x70 19/217 : 18 22.0 1115 223 230 1x95 19/252 0.193 34 18 27 1400 268 280 1x120 37/ 2.03 0.153 34 18 25.4 1670 300 325 1x150 37/227 aaa 34 18 270 1980 335 365 1x 185 37/252 0.091 34 20 29.0 2380 380 420 1x 240 61/224 0.0754 34 20 318 3010 450 500 1300 61/250 0.0601 34 20 3590 490 580 1x40 61/289 0.0470 34 22 4630 570 690 1x 500 61/3.23 0.0366 34 24 as 5670 645 75 1x630 127/252 0.0283 34 24 45.2 7020 730 900 3x25rm 7/214 0727 34 22 36.2 2015 105 105 3x35m 19/153 0.524 34 22 39.4 2480 125 125 3xs0rm 19/183 0.387, 34 22 426 3100 145 155 3x70rm 19/217 0.268. 34 26 470 3950 180 190 3x95rm 19/252 0.193, 34 26 514 4900 215 235 3x1201m 37/203 0.153 34 26 545 5950 245 270 3x150rm 37/227 0.424 34 3.0 59.2 7200 275 305, 3x1851m 37/252 0.0991 34 3.0 34 8550 305 350 3x2401m 61/224 0.0754 34 34 69.8 10700 350 405 3x300rm 61/250 0.0601 34 34 755 13020 390, 460 Ensure Quality Product 26 Conductor: Copper Cond, Serean Extruded Semicon Insulaton = PVC Inet Screen: Extruded Semicon le Sereon Copper Inner Sheath: PVC 7. Arm: Fat Gav Stel wire 8. Sheath: PVC ‘Standard: VDE-0271/3.69 Eos Voltage: 5800/1000 volts ite ‘Type: NYSEYFGbY sit Construction Plain annealed Copper Conductor, PVC Insulated, Field limiting semi-conducting layer over each conductor and each core insulation, Copper shield over each core, three cores laid up, PVC inner sheath (bedding), Flat galv, steel wire armouring with helical steel tape binder & PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 7000/12000 volts. Cour of sheath : RED rere and] Max DC | Nomi Cy a os resistance of| thickness | thickness | overall ag sedtonal | diameter | Conductor | of Cae es ‘rea of | of Wires | at20 | insuation | sheath fone 3x25rm 7/214 3x35mm 19/153 3xS0rm 19/183 0.387 40 3.0 59.0 5840 140. 145 3x70m = 19/217 0.268 490 3.0 62.5 7100 170 180 3x95mm 19/252 0.193, 49 3.0 68.0 8600 200 20 3x1201m © 37/203, 0.153 40 34 no 9900 230 250 3x1501m 37/227 0.424 49 34 m5 11400 260 290 3x1851m 37/252 0.0991 40 38 795 13100 290 325 3x2401m 61/224 0.0754 40 38 86.3 15000 320 370 3x3001m 61/250 0.0601 490 42 93.5 17800 365 425 Ea 7 Tyee: vA le ce Standard: VDE-0250/3.69 2. Insulation : PVC. Voltage: 600/1000 volts Construction Plain annealed Copper Conductor, PVC Insulated and left bare. Suitable for use in motor and switch panels and in distribution equipment. Cables of 1.5 mm® and above are for use in conduit over and under plaster and over insulating bodies over plaster in dry rooms, for continuous permissible service voltage of 690/1150 volts. CET ea) No. and Coad Co ‘Cross Resistance of | —thicknes Sectional romaine of ot = ry 1x0.75 re 1x10re 15 10 7 tease 20 4 2 1x250e 30 18 30 1x40r0 50 2 39 1x6.0re oe 30 50 1x10re 12 2 6 1x16 re 170 7 2 Type: NYIFY Standard: VDE-0250/3.69 a= _ 4. Conductor : Copper Voltage: 220/380 volts —__ Se 2 Insulation: PVC 3, Sheath : PVC Construction Plain annealed Copper Conductor, PVC Insulated, TWIN or THREE core laid Flat and PVC sheathed overall. Suitable for use on or under plaster in dry rooms for continuous permissible service of 255/440 volts. Colour of sheath: WHITE oe Nominal Nominal ery eas oa easy coo 2x15 re 1/138 2a os 2x25r0 1/178 zat os . 50x80 2x40re 1/2226 41 06 . 57x92 3x15 re 1/138 aa oa . 42x 8.8 3x25re 1/178 7an os . 5.0% 10.8 3x40re 1/226 et 06 . 57x 129 SINCE - 1978 EI 28 ‘Type: NYMT 4. Conductor: Copper Standard: VDE-0250/3.69 2. Insulation : PVC Voltage: 300/500 volts 3. Common Covering : PVC 4, Gav, Steel wire ope 5. Sheath : PVC Construction Plain annealed Copper Conductor, PVC Insulated, Two, Three or Four cores laid up, filled & PVC sheathed overall along with a galvanized steel wire rope under the sheath, Suitable for use as self supporting aerial cable for continuous permissible service voltage of 345/575 volts. Colour of sheath: BLACK PCED Nominal Max.0C Nominal ] Nominal | Maximum | Approx Co ey outer weight of } Ratingat eso Cees ey 35°C Cory eased fearing ccMOrLs 2x2Sre 1/178 19/06 741 07 14 250 2B 2x4re 1/226 19/06 461 08 14 125 330 31 2x6re 1/277 19/06 3.08 08 14 35 400 4“ 3x15 1/138 19/06 a 06 14 105 25 7 3x25re 1/178 19/06 741 o7 14 115 280 2B 3x4re 1/226 19/06 461 08 14 130 376 31 3x6re 1/277 19/06 3.08 08 16 15.0 507 al 4x15 1/138 19/06 121 06 14 11.0 250 7 4x25re 1/178 19/06 7A 07 14 125 320 2B 4x4re 1/226 19/06 461 08 16 145 460 31 4x6re 1/277 19/06 3.08 08 16 165 590 4“ EN 29 atl_______ ‘Type: FLEXIBLE CORDS 4. Conductor : Copper Standard: BDS - 899 and BS - 6500 =o 2. Insulation : PVC Voltage: 300/500 volts 3. Sheath : PVC Construction Plain annealed Flexible Copper Conductor, PVC Insulated, Cores twisted together & PVC sheathed overall. PECTED Nominal] No.and J Max.0c J Nominal [Nominal | Approx | Approx ceed) ee 7 | =a cs ri sheath | diameter Teonats | in Stee ‘Area of | of Wires pet ag ca ee 14/019 3 16 /0.20 3 2x065 23/019 28.60 06 08 66 60 5 6 2x075 24/0.20 26.00 06 08 67 64 6 7 2x10 32/020 19.50 06 08 7 75 40 un 2x12 40/0.19 16.44 07 08 76 85 13 15 2x15 30/025 13.30 07 08 80 96 15 16 2x20 70/0.19 9.40 08 09 on 128 18 20 2x25 50/0.25 798 08 10 97 148 20 a 2x30 © 110/019 5.98 08 10 103 170 4 25 2x40 56/030 495 08 ree 110 202 25 26 3x04 14/019 46.98 06 08 64 57 2 3 3x05 16/020 39.00 06 08 67 64 3 4 3x065 23/019 28.60 06 08 70 70 5 6 3x075 24/0.20 26.00 06 08 7A 75 6 7 3x10 32/020 19.50 06 08 75 88 40 un 3x12 40/0.19 16.44 07 09 83 105 rv 4 3x15 30/025 13.30 07 09 88 a2 45 16 3x20 70/0.19 9.40 08 10 100 157 16 20 3x25 50/0.25 798 08 aa 106 184 20 a 3x30 110/019 5.98 os 4 13 212 a 24 3x40 56/030 495 08 12 120 254 Fey 26 EI 30 ‘Type: FLEXIBLE CORDS a 4. Conductor : Copper Standard: BDS - 899 and BS - 6500 =o 2. Insulation : PVC Voltage: 300/500 volts 3, Sheath : PVC Construction Plain annealed Flexible Copper Conductor, PVC Insulated, Cores twisted together & PVC sheathed overall. ~ _ af one oe at 35°C for fearing 14/019 2 16 /0.20 3 4x065 23/019 28.60 06 08 76 86 5 6 4x075 24/020 26.00 06 08 78 92 6 7 4x10 32/0.20 19.50 06 09 a4 12 40 un 4x12 40/0.19 16.44 07 10 92 135 rv 4 4x15 30/0.25 13.30 07 10 97 155 45 16 4x20 70/0.19 9.40, 08 Ad 14 202 16 20 4x25 $0/0.25 798 08 aa 116 26 20 a 4x30 110/019 5.98 08 12 124 268 a 24 4x40 56/030 495 08 12 132 315 5 26 EI 31 ‘Type: FLEXIBLE SCREEN CABLE 4. Conductor : Copper Standard: BS - 6004 : 2000 2. Insulation : PVC. Voltage: 300/500 volts 3. Inner Sheath : PVC 4, Braid : Copper wire 5. Sheath : PVC Construction Plain annealed Flexible Copper Conductor, PVC Insulated, Cores twisted together & PVC Inner Sheath, Plain annealed copper wire braid, PVC sheathed overall. ErCeE4 Nominal | No.and ] Max.0¢ | piameter | Nominal | Nominal | Nominal | Approx ce Nominal] Resistan of braid | thickness } thickness | thickness | overall Sectional | damete od of of | of sheath | dameter ‘rea of etn Insulation | Inner (ost Sheath mm ‘kg/km amp 2x05 16/020 39.00 01506 07 s 92 «G2 3 2x075 24/020 26000506. 07 09 96 BS 6 2x10 32/020 1950 0s 07 09 100i 9 2x15 30/025 13:30 0s. 07 19 2B “4 2x25 50/025 798 = Os 07 110 eB 19 2x40 $6/0.30 495 OSB o7 1 Bs 8B m4 3x05 16/020 3900 0.150 07 09 96 02 3 3x075 24/020 2600 0s 07 09 0S 6 3x10 32/0.20 1950050 07 1006 = 657 8 3x15 30/025 1330 0s 07 100 7a 3 3x25 50/025 798 «OS 07 1 B30 7817 18 3x40 56/030 495 01S, 07 1200 «150368 2 4x05 16/020 39.00 as 07 09 02a 3 4x075 24/020 2600 01506 o7 19 09 4x10 32/020 1950 0S 06 07 1 327 8 4x15 30/025 1330 oso 07 ret 27 72 B 4x25 50/025 798 OSB 08 1200 4B 7 18 4x40 56/030 495 0s O8 08 1300 640 ats 2 5x05 16/020 3900 050 o7 190 «0 3 5x075 24/020 2600 © 01s 06 07 1906s 6 5x10 32/0.20 1950 050 07 1 R326 SO 8 5x15 30/025 133001507 08 1200 40k 3 5x25 50/025 798 020208 08 1300 «64043017 18 5x40 56/030 495 0.2008 08 14 L555 2 EI 32 ‘Type: FLEXIBLE SCREEN CABLE 4. Conductor : Copper Standard: BS - 6004 : 2000 2. Insulation : PVC. Voltage: 300/500 volts 3. Inner Sheath : PVC 4, Braid : Copper wire 5. Sheath : PVC Construction Plain annealed Flexible Copper Conductor, PVC Insulated, Cores twisted together & PVC Inner Sheath, Plain annealed copper wire braid, PVC sheathed overall. ErCNEZ Pen ore Cry cory oct 12x05 120.75 12x10 2x15 12x25 18x05 18x 0.75 18x10 18x15 18x25 No.and } Mex.0C | Diameter | Nominal | Nominal | Nominal | Approx Nominal | Resistance | of braid | thickness | thickness J thickness | overall Coe ductor] wire ca ‘of | of sheath | diameter Eoin rents Mec Sr mm kgikm amp 16/020 39.00 os 06 O7 117 189) 2 3 24/0.20° 26.00 os 06 07 125 222 5 6 32/020 19.50 os 06 o7 at 13.0 247 7 8 30/0.25 13.30 os 07 08 12 149 335, 2 B 50/0.25 7.98 0.20 08 08 14 178 500 7 18 56/030 4.95 0.20 08 08 15 196 652 2 B 16/020 39.00 os 06 07 1 120 198 3 24/020 26.00 os 06 o7 12 128 235 5 6 32/020 19.50 os 06 08 12 135 266 8 30/025 13.30 0.20 o7 08 13 15.6 392 2 3 50/0.25 7.98 0.20 08 08 15 18.41 530 7 18 56/030 4.95 0.20 08 09 17 202 72 22 2B 16/020 39.00 0.20 06 08 13 155 360 2 3 24/0.20° 26.00 0.20 06 08 13 16.4 410 5 32/020 19.50 0.20 06 08 14 173, 466 6 7 30/025 13.30 0.20 07 08 15 196 610 u 2 50/0.25 7.98 0.20 08 09 17 23.0 873 16 v7 16/020 39.00 0.20 06 08 13 4 448 2 3 24/0.20 26.00 0.20 06 08 15 188 548, 5 32/020 19.50 0.20 06 08 15 198 621 6 7 30/0.25 13.30 0.20 07 08 17 26 832 u 2 50/0.25 7.98 0.20 08 09 20 28 121016 v7 EI Type: PVC Insulated Flexible cable 33 Voltage: 300/500 volts Standard: BS-6004 & BDS-899 1. Conductor : Copper 2. Insulation : PVC. Construction Plain annealed Flexible Copper Conductor, PVC Insulated, single / Twin core twisted with suitable lay. rey oe Nominal ‘Approx ‘ApprOX ES Canines ts 14/ 0.19 7 ° 16/0.20 se 23 10 23/0.19 24 a 24/020 25 a 32/020 , 27 as 40 /0.19 , 28 v7 30 / 0.25 32 23 14 700.19 35 28 16 50 / 0.25 38 35 19 1107 0.19 : 4a 43 a 56 / 0.30 aa st 23 14/019 22 v7 2 23/019 . 24 23 5 40 /0.19 28 34 a 70/019 35 56 Fe a ‘Type: Flat Flexible Cord cg «1 Conductor : Copper ‘Standard: BDS-899 ——=__ ee 2. Insulation : PVC Votage: 300/500 vot 3. Sheath : PVC Construction Plain annealed Flexible Copper conductor, PVC insulated (Red and Black colour), cores laid side by side & PVC sheathed ‘Twin core Flat cable. oy iE cd ad Lo Lo er Era Coy Pee thickness | thickness Cot Peri Piensa cee ceeg 7 of coe oun Cory ear et) Se oer en no) Er En 20.40 14/019 3 4 20.65 23/019 6 cI Ema 34 Type: NYY ( Flexible ) 4. Conductor : Copper Standard : BDS IEC-60502 & VDE-0271/3.69 2. Insulation : PVC Voltage: 600/1000 volts 3. Common Covering : PVC 4. Sheath : PVC Construction Plain annealed Flexible stranded Copper conductor, PVC Insulated, single / Multi cores laid up with filling compound if necessary & PVC sheathed overall. Suitable for use in single / three phase connections, electric connection for cranes, hoists ‘or any mobile overhead power driven equipment. Colour of sheath : BLACK Nominal No. and ras Nominal roy ro Cis Cro Nominal Resistance thickness of | overall eee Sectional | diameter | of Conductor | Ini sheath diameter eon eae Bot Penn fan Sara mm mm oa 1x 1.0m 32/0.20 195 08 18 69 1xi.5em 30/ 0.25 133 os 18 72 125mm 50 / 0.25 798 09 18 78 Ax4rm 56 / 0.30 4.95 10 18 86 1x6rm 84/030 3.30 10 18 93 1x 101m 80 / 0.40 191 10 18 103 1x 164m 126 / 0.40, 1.29 10 18 47 4x 251m 196 / 0.40, 0.780 12 18 B36 379 131 1x35 rm 276 / 0.40 0.554 12 18 15.0 490 167 1 x501m 396 / 0.40 0.386 14 18 172 675 204 1x 701m 360 / 0.50 0.272 14 18 19.1 890 256 1x95 rm 475 / 0.50 0.206 16 18 21.6 1170 314 1x 120m 608 /0.50 0.161 16 18 24 1430 366 1x 150m -760/0.50 0.129 18 18 25.7 1760 423 1x185rm —-950/ 0.50 0.106 20 20 285 2195 478 21.01 32/0.20 195 08 18 116 475 2 2x15 1m 30/ 0.25 33 os 18 22 198 20 2x25mm — 50/0.25 798 09 18 BS 245 28 2x40m 56 / 0.30 4.95 10 18 15.0 313 7 2x60m 84/030 3.30 10 18 170 400 47 2x 101m 80 / 0.40 191 10 18 18.5 528 4 2x16 rm 126 / 0.40, 1.21 10 18 aa 750 86 2x25 1m 196 / 0.40, 0.780 12 20 263 1135 112 2x354m 276 / 0.40 0.554 12 20 292 1450 142 EI 35 Type: NYY ( Flexible ) 4. Conductor : Copper Standard : BDS IEC-60502 & VDE-0271/3.69 2. Insulation : PVC Voltage: 600/1000 volts 3. Common Covering : PVC 4. Sheath : PVC Construction Plain annealed Flexible stranded Copper conductor, PVC Insulated, single / Multi cores laid up with filling compound if necessary & PVC sheathed overall. Suitable for use in single / three phase connections, electric connection for cranes, hoists ‘or any mobile overhead power driven equipment. Colour of sheath : BLACK Nominal No. and ras Nominal roy ro Cis Cro Nominal Resistance thickness of | overall eee Sectional | diameter | of Conductor | Ini sheath diameter eon er eae Bot Inductor en fan Sara En mm oa 3xL00m 32 /0.20 195 08 18 12.2 3x15 1m 30/0.25 133 os 18 127 3x25m — 50/0.25 798 09 18 444 3x4im 56 / 0.30 4.95 10 18 16.1 3x60m 84/030 3.30 10 18 77 3x 101m 80 / 0.40 191 10 18 19.8 3x16 rm 126 / 0.40, 121 10 18 238 3x25 4m 196 / 0.40, 0.780 12 20 28.2 1430 102 3x354rm 276 / 0.40 0.554 12 20 31.0 1840 125 4x10 9m 32/0.20 195 08 18 13.0 26 2 4x15 1m 30/ 0.25 133 os 18 13.6 260 v7 4x25mm —— 50/0.25 798 09 18 15.2 345 24 4x4im 56 / 0.30 4.95 10 18 76 460 3B 4x60m 84/0.30 3.30 10 18 18.9 575 3 4x 101m 80 / 0.40 191 10 18 22.0 835 58 4x16 rm 126 / 0.40, 1.21 10 20 26.2 4210 78 4x25 4m 196 / 0.40, 0.780 12 20 30.6 1740 102 4x35 rm 276 / 0.40 0.554 12 20 34a 280 125 Ensure Qual 36 41. Conductor : Copper 2. Insulation : PVC 3. Sheath : PVC ‘Type: NYAB Voltage: 600/100 volts Construction Plain annealed flexible Copper conductor & PVC Insulated cable. Suitable for use in temporary installation for electric connection, decorative illumination for continuous permissible service voltage 690 / 1150 V. CRE) Nominal or nd od es Cy Nominal Cet eer weight of pst Crocs cs Pen) 56 / 0.30 1x6.01m 84/030 1x 101m 80 / 0.40 1x 161m 126 / 0.40 1.29 12 9 198 98 1x25 1m 196 / 0.40, 0.780 14 10.9 305 Bt 1x35 1m 276 0.40 0.554 14 123 405 167 1x501m 396 / 0.40 0.386 16 145 7. 204 1x701m 360 / 0.50 0.272 16 16.5 780 256 1x95 1m 475 / 0.50 0.206 18 19.0 1040 314 1x 120m 608 / 0.50 0.61 18 20.5 1275 366 1x 150 rm 760 / 0.50 0.129 20 23.0 1600 23 1x 185 rm 950 / 0.50 0.106 22 25.3 1970 478 Ea 7 ‘Type: WELDING CABLES ‘ 4. Conductor: Copper Voltage: 200 volts a 2. Insulation : PVC Construction Plain annealed Flexible Copper conductor, covering with PVC tape or cotton tape (OPTIONAL) and PVC sheathed overall. Colour of Sheath: BLACK Table : 30 ra or nd od Approx. Corns co Nominal Ct Cec weight of Snr Carl Se Crocs oon tors 7 a 1x25rm 854 / 0.19 5 169 1x35rm 1196 / 0.19 0.554 2a BS 455 215 1x50rm 1708 / 0.19 0.386 24 15.0 608 264 1x70 2392 / 0.19 022 22 176 826 330 1x95rm 3247 / 0.19 0.206 22 195 1065 405 1x1201m 4101 /0.19 ost 22 23.0 1328 473 | fetes ‘Type: CO-AXIAL CABLES Lhe moaniene 1. Conductor : Copper ‘Standard ; MIL-C-17, 2. Insulation : PE 3. Copper wire braided 5 4, Oversheath : PVC Construction Plain annealed Copper conductor, Polythene insulated, Copper wires braided and PVC sheathed overall. Suitable for use as aerial down leads in local and fringe reception areas at both very high frequency and ultra high frequency. Table : 31 Pe No. and or Nominal oad Approx ad Gs Nominal Crs Cert Went at con ree peter Ea 38 NON SHEATHED FLAME RETARDENT CABLES | LH 41. Conductor : Copper ‘Type: BYA-FR. 2. Insulation : PVC-FR Standard: BDS - 900 BS - 6004 and IEC 60332 Voltage: 450/750 volts Construction Plain annealed Copper conductor, PVC Insulated non-sheathed Single core FR type cable. Suitable for use in Surface mounted or embedded conduits or trunking. Also suitable for field protected installation in lighting fittings and inside appliances up to 1000 V (a.c) or upto 750 V to earth (d.c). Table : 32 Nominal ror wed fond Cr Nominal | R ee ee Se or peer od Eero phase at 35C ot ‘unendosed 2 posers tra cari 10 re °. 1.0 rm 13m 142 7 15 re 124 07 15m aaa 07 201m 9.30 os 36 30 25 re 741 os 35 32 25m 741 08 37 4 3.00m 6.0 8 39 40 4.01m 461 os 43 50 4sim 401 os 45 56 601m 3.08 08 49 nm 70 rm 2.65 10 55 85 951m ast 10 61 113 st 10m 1.83 1.0 62 417 52 14.5 1m 1.25 10 70 164 6s 16m 1.45 10 73 178 70 161m 145 10 24 180 70 251m 0727 12 9.0 280 on 110 251m 19/130 0727 12 1 282 on 110 351m 19/153 0.524 12 103 373 412 136 50 rm 19/1.83 0.387 14 12.2 535, 136 164 701m 19/217 0.268 14 Bo 735 173 207 951m 19/252 0.193, 16 16.0 985, 216 253 120m 37/2.03 0.153 16 176 1225 244 201 150 1™m 37/227 0.124 18 19.7 1530 : 333 185 rm 37/252 0.0991 20 218 1882 > 381 240m 61/224 0.0754 22 249 2445 2 452 300 em 61/250 0.0601 24 276 3042 : 526 4400 rm 61/289 0.0470 26 315 4030 : 639 500 rm 61/3.23 0.0366 28 35.0 5010 > 752 630 em 327/252 0.0283 28 38.8 6280 2 855 Fe EE A) 39 41. Conductor : Copper 2. Insulation : PVC 3. Sheath : PVC. ‘ FLAME RETARDENT SHEATHED CABLES: I Type: NYY-FR t ‘Standard: VDE — 0271/3.69 & IEC 60332 Voltage: 600/1000 volts Cet eUrey Construction Plain annealed Copper Conductor, PVC insulated, PVC sheathed FR Type, Single core cable. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts Colour of Sheath: BLACK. Nominal] No.and | Max.DC | Nomin Nominal | Approx ADDTOX. Cross Nominal JResistance of] thickness | thickness of } overall et TA Sectional | diameter | Conductor ea sheath | diameter ‘Area of | of Wires | at 20°C | insulation aie eed ixiSre | Y/138 124 18 ixi5em 7/052 14 oa 18 1x25re | Y/1.78 741 09 18 1x251m — 7/0.67 7a 08 18 ix4rm 7/085 461 10 18 83 413 47 39 tx6rm 71.05 3.08, 10 18 88 140 59 50 1x10 7/135 1.83 10 18 98 190 7 69 Axt6im 7/171 1.45 1.0 18 10.8 262 100 94 1x16rm —19/1.04 1.45 10 18 110 268 100 4 1x2sim 7/244 0.727 12 18 12.6 375 130 125 1x25m 19/130 0.727 12 18 128 385 130 125 1x351m 19/153 0.524 12 18 139 482 155 160 1x50rm 19/183 0.387 14 18 158 660 185, 195 1x70rm 19/217 0.268 14 18 178 870 225 245 1x951m 19/252 0.193 16 18 20.0 1145 270 300 1x120rm 3772030453 16 18 216 1400 310 350 1x1501m —37/2.27 0.124 18 18 23.7 1735 350 405 1x1851m 377252 0.0991 20 20 26.3 2130 330 460 1x2401m 61/224 0.0754 22 20 29.3, 2735 450 555 1x3001m 61/250 (0.0601 24 20 32.2 3342 515 640 1x4001m —61/2.89 (0.0470 26 22 36.0 4430 585 7 1x5001m — 61/3.23 (0.0366 30 22 403 500 680 900 1x630rm 127/252 (0.0283, 30 22 42 6810 800 1030 1x8001m 127/284 (0.0221 3.0 24 49.1 8520 945 1160 1x 1000%m —127/3.17 0.0176 30 28 540 10500 1095 1310 & EE 40 3 FLAME RETARDENT SHEATHED CABLES 4. Conductor : Copper Type: NYY-FR 2. Insulation : PVG, Standard: VDE-0271/3.69 & IEC-60332 3. Common Covering : PVC Voltage: 600/1000 volts 4, Sheath : PVC. Construction Plain Annealed Copper Conductor, PVC Insulated, Cores laid up, PVC common covering & PVC-FR sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath: BLACK. Nominal | No.and | Max. Dc Nominal | Approx ord 55 Nominal J Resistance of thickness of | overall iT sectional | diameter | Conductor sheath | diameter cone ‘Area of | of Wires penis cain 2xi5re 1/138 18 2x15rm — 7/0.52 18 2x25re —/L78 r 18 2x251m 7/067 x 18 2x40rm — 7/085 . 1.8 2x6.0rm —7/1.05 18 2xtom = 7/1.35 1.83 10 18 18.1 550 4 2 2x16m = 7/2.72 145 10 18 20.2 720 97 a4 2x251m 7/214 077 12 18 245 1050 125 10 2x351m —19/1.53 0.524 12 20 274 1350 150 140 3x1Sre 1/138 124 8 18 12a 200 2 16 3x15 7/052 124 os 18 125 210 2 16 3x25re 178 at 09 18 135 266 30 2B 3x251m 7/067 741 09 18 14.0 275 30 2B 3x40rm ——7/0.85 461 1.0 18 158 376 38 32 3x6.0rm —7/1.05 3.08, 10 18 170 465 48 at 3x10Mm = 7/2.35 1.83, 10 18 19.0 650 64 56 Bx16rm 21.7 145 10 18 219 900 83 5 3x251m —-7/2.14 on 12 20 25.8 1360 110 98 3x35sm — Min6wire 0.524 12 18 235 1440 130 120 3x50sm — Min6 wire 0.387 14 2.0 279 2000 155 150 3x70sm Min i2wire 0,268 14 20 30.0 2600 190 190 3x95sm Min 15 wire 0.193, 16 20 345 3850 225 230 3x120sm Min 18 wire 0.153 16 22 a7, 4300 260 270 3x150sm Min 18 wire 0.124 18 22 410 5300 295 305 3x185sm Min 30 wire 0.0991 20 22 45 6460 330 350 3x240sm —Min34wire 0.0754 22 26 50.5 8380 385 410 3x300sm Min 34 wire 0.0601 24 26 55.2 10350 425 470 & EE 41 FLAME RETARDENT SHEATHED CABLES 4. Conductor : Copper Type: NYY-FR 2. Insulation : PVG, Standard: VDE-0271/3.69 & IEC-60332 3. Common Covering : PVC Voltage: 600/1000 volts 4, Sheath : PVC. Construction Plain Annealed Copper Conductor, PVC Insulated, Cores laid up, PVC common covering & PVC-FR sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath: BLACK. rere Wax. DC Nomi Nominal [Approx | Approx ee minal} Resistance Ee pee ag sedtonal | diameter | of ry eee es ‘rea of | of Wires | Conductor | insulation fone Be rod 4xisre 1/138 124 08 18 13.0 255 2 4x15m 7/052 14 os 18 3B3 260 2 16 4x25re 1/178 741 09 18 145 330 30 2B 4x25m 7/067 744 09 18 148 360 30 2B 4x4im 7/0.85 461 10 18 170 460 38 32 4x64m 711.05 3.08 10 18 18.4 600 48 au 4x10m = 7/1.35 1.83 10 18 20.6 20 «4 56 4x16m 7/74 145 10 18 240 1150 83 B 4x25mm 7/214 727 12 20 28.5 1730 110 98 4x35sm — Min6wire 0,524 12 20. m2 1950 130 120 4x50sm — Min6wire 0,387 14 20 29.8 2620 155 150 4x70sm Min 12wire 0.268 14 20 35.2 3460 190 390 4x95sm Min iS wire 0,193 16 22 39.3 4800 2s 230 4x1205m Min 18 wire 0.153 16 22 42.0 5700 260 270 4x150sm Min 18 wire 0.124 18 26 465 7080 295 305 4x185sm Min 30 wire 90,0991, 20 26 514 8640 330 350 4x240sm —Min34wire 0.0754 22 3.0 58.0 11300 385 410 4x300sm Min 34wire 0.0601, 24 3.0 642 13760 425 470 Ensure Quality Product 2 41. Conductor : Copper 2. Insulation : PVC 3. Sheath : PVC. ‘Type: YY Standard : IEC-60502-1 t Voltage: 600/1000 volts CU et) Construction Plain annealed Copper Conductor, PVC Insulated and PVC sheathed Single core Cable. Suitable for use in indoors, outdoors, underground and in water for continuous service voltage of 720/1200 volts. Colour of Sheath : BLACK Table : 36 Nominal I CN PC a as STE fess ||tseknesser | |) overal cor [Under Pee es sheath | diameter around at ‘weaot | of Wes Ea fearing 7/082 ix25re 1/178 241 08 14 65 68 36 30 1x251m —-7/ 0.67 741 08 14 68 n 36 30 ix4m 7/085 461 1.0 14 79 100 47 39 1x6m = -7/ 1.05 3.08 10 14 84 125 59 50 1x10m 7/135 1.83 10 14 93 170 78 69 1xi6m 7/471 15 1.0 14 105 240 100 94 1x251m 7/214 077 12 14 22 348 130 125 1x35rm —19/1.53 0524 12 14 135 455 155 160 Ax50rm — 19/1.83 0.387 14 14 155 625 185 195 1x70rm 19/217 0.268 14 14 172 835 225 245 1x951m —19/2.52 0.193 16 15 194 1110 270 300 1x120em 37 /2.03 0.153 16 15 21.0 1365 310 350 1x 150m 37/227 0.124 18 16 23.0 1700 350 405 1x 185m 37/252 09,0991 2.0 17 26.0 2090 390 460 1x240mm —61/2.24 0.0754 22 18 29.0 2695 450 555 1x300Mm 61/250 0,0601, 24 19 320 3335 515 640 1x400Mm 61/289 0.0470 26 20 357 4350 585 77 1x500Mm — 61/3.23 0.0366 28 2a 40.0 5350 680 900 1x630Mm 127/252 0.0283 28 22 44.0 6700 ‘800 1030 1x800Mm — 127/285 0.0221 28 23 48.6 8460 945; 1160 1x1000rm —127/3.20 0.0176 3.0 25 540 10640 1095 1310 SUES 43 Type: YY Standard : IEC-60502-1 Voltage: 600/1000 volts 4. Conductor : Copper 2. Insulation : PVC 3. Common Covering : PVC 4, Sheath : PVC. LT Poteet eons Construction Plain annealed Copper Conductor, PVC Insulated, cores laid up, PVC inner covering and PVC sheathed Overall. Suitable for use in indoors, outdoors, underground and in water for continuous service voltage of 720/1200 volts. Colour of Sheath : BLACK Table : 37 Max.0¢ | Nominal | Nominal | Approx ned Resistance of| thi eri trices | etter Ca! fn mm 2xiste 1/138 124 OB 18 2x25te 1/178 7a 08 18 2x4rm 7 /0.85 461 1.0 18 2x6m ——-7/1.05 3.08 1.0 18 2x10rm 7/135 1.83 1.0 18 18.1 512 "4 2 2x16 7/171 15 1.0 18 202 690 7 4 2x251m = 7/214 on 12 18 240 1020 125 110 2x35mm 19/153, 0524 12 18 265 1300 150 140 3xiSte 1/138 124 08 18 23 205 2 16 3x25re 1/178 741 08 18 136 260 30 2 3x4m 7/085 461 1.0 18 159 375 38 32 3x6rm = 7/4.05 3.08 10 18 172 470 48 at 3x10Mm = 7/135 1.83 10 18 19.2 640 64 56 3x16rm 7/471 15 1.0 18 214 880 83 5 3x25mm 7/214 on7 12 18 25.2 1260 110 98 3x35sm — Min6wire 0,524 12 18 235 1400 130 120 3x50sm — Min6wire 0.387 14 18 265 1910 155 350 3x70sm Min 12wire 0.268 14 20 30.0 2600 190 390 3x95sm Min 15 wire 0.193 16 2a 345 3440 25 230 3x120sm Min 18 wire 0,153 16 22 370 4220 260 270 3x150sm Min 1Bwire 0,124 18 23 a2 5250 295 305 3x185sm Min 30wire 0.0991 20 25 45.0 6400 30 350 3x240sm Min34wire 0.0754 22 27 51.0 8400 385 410 3x300sm Min34wire 0.0601 24 29 55.8 10250 25, 470 EE Type: YY 4. Conductor : Copper Standard : TEC - 60502 -1 CLAS 2. Insulation : PVC Voltage: 600/1000 volts 3. Inner Covering : PVC 4, Oversheath : PVC Table : 38, Pea Max.0¢ | Nominal | Nominal | Approx: rod or Nominal Resistance of] thickness | thickness of | overall ee under Sectional | ciameter of sheath | diameter Cable Pte ‘area of | of Wires er sec ete mm mm oi 3x25mm/ 7/214 0.727 12 18 27.0 1xi6rm 7/471 Las 10 3x35sm/ — Min6wire 0.524 12 18 264 1650 130 120 1xi6rm 7/171 15 1.0 3x50sm/ Min 6 wire 0.387 14 19 29.0 2280 155 150 Ax25rm 7/214 0.77 10 3x70sm/ Min 12wire 0.268 14 20 342 3100 190 190 1x35rm —19/ 1.53 0.524 12 3x95sm/ Min iS wire 0,193 16 22 38.2 4120 225 230 1x50Mm — 19/1.83 0.387 14 3x120sm/ Min 18 wire 0.153, 16 23 a7 5200 260 20 1x70rm 19/217 0.268 14 3x150sm/ Min 18 wire 0.124 18 24 “48 6200 295 305 1x70rm 19/217 0.268 14 3x185sm/ Min 30 wire 0.0991 20 26 51.0 7750 330 350 1x95em 19/252 0.193 16 3x240sm/ Min 34wire 0.0754 22 28 56.2 9930 385 410 1x120¢m 37/203 0.153 16 3x300sm/ Min 34wire 0.0601 24 30 63.0 12200 25, 40 1x1500m — 37/2.27 0.124 18 EE Type: YY Standard : IEC-60502-1 Voltage: 600/1000 volts Construction ( . Contd.) Table : 39 ro Max. DC Cr Resistance ot| Sectional | diameter | Conductor at] ‘Area of | of Wires Ered ferns enn 4x15 12 4x25 re 4x4im 7/085 461 4x6mm = 7/105 3.08 4x10m 7/135 1.83 4x16m = 7/171 15 4x25m 7/214 077 4x35sm — Min6wire 0,524 4x50sm — Min6wire 0,387 4x70sm — Min 12 wire 0.268 4x95sm Min 15 wire 0.193, 4x120sm Min 18 wire 0.153 4x150sm Min 18 wire 0.124 4x185sm Min 30 wire 0.0991 4x240sm — Min34wire 0.0754 4300 sm Min 34 wire 0,060, a thickness ea pet 1.0 1.0 12 12 14 14 16 16 18 20 22 24 ao td cot 18 18 18 18 18 18 19 2a 22 24 25 27 29 3a & ‘Approx ot Cron 173 187 210 237 276 265 29.6 35.0 38.8 423 454 520 572 64.0 ‘ADDTOX, ct 790 1130 1600 1800 2530 3450 4510 5600 6900 18500 11000 13500 4. Conductor : Copper 2. Insulation : PVG. 3, Inner Covering : PVC 4, Oversheath : PVC eI org Pony Eire 38 2 48 a 64 56 83 5 110 98 130 120 155 150 190 190 225 230 260 20 295 305 30 350 385 410 425 470 45 Ensure Qual 46 Type: YRaY 4. Conductor : Copper Standard : IEC-60502-1 ETT avs) 2. Insulation : PVC Voltage: 600/1000 volts 3. Inner covering : PVC 4. Armour : Round Al. wire 5. Oversheath : PVC Construction Plain annealed Copper Conductor, PVC Insulated, PVC inner covering single layer round hard drawn aluminium wires armouring & PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath : BLACK PET) Nominal [ No. and | Max.DC | Nominal [ Nominal | Nominal | Approx | Approx Cross | Nominal | Resistance | thickness | diameter | thickness | overall | weight of [Under Sectional ] diameter fof Conducto] of — | of round cof | diameter | Cable } ground ‘Area of | of Wires | at 20°C | Insulation | Armour | Sheath Ean ears rid ets Sra Cia) 1x35 1m x 0.524 E r 173) 625 1x50rm 19/183 0,387 14 1.25 18 19.2 815 185 195 1x70rm 19/247 0.268 14 125 18 209 1050 25 245, 1x951m 19/252 0.193 16 125 18 Bo 1328 20 300 1x120Mm 37/203 0.153 16 16 18 255 1660 310 350 1x150mm 37/227 0,124 18 16 18 278 2000 350 405 1x 1851 37/252 0.0991 20 16 18 300 2410 390 460 1x2400m —61/2.24 0.0754 22 16 19 330 3050 450 555 1x300mm 61/250 0,0601 24 20 20 365 3820 515 640 1x400Mm 61/289 0.0470 26 20 24 4104900 585 77 1x500Mm 61/323 0.0366 28 20 22 445 6000 680 900 1x6301m 127/252 0.0283 28 20 24 485 7370 800 1030 1x800Mm 127/285 0,021 28 25 25 55.0 9400 945, 1160 1x 1000rm 127/320 0.0176 30 25 27 60.0 11650 1095 1310 EE 47 ‘Type: YRGY , 4. Conductor : Copper Standard : TEC-60502-1 2. Insulation : PVC Voltage: 600/1000 volts 3. Inner covering : PVC. 4, Armour : Round steel wire 5. Helical steel tape (optional) 6. Oversheath : PVC. Construction Plain annealed Copper Conductor, PVC Insulated, cores laid up, PVC inner covering, Round Galv. Steel wires armouring with ‘or without helical steel tape binder and PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath : BLACK Nominal | No. and 7 Nominal | Nominal | Approx | Approx Cross} Nominal | thickness | diameter | thickness | overall | weight of [Under Sectional | diameter of | ofround | of | diameter | cable | ground ‘Area of | of Wires Insulation | Armour | Sheath Earle Coarccas or fet Sra Cia) 3x4m . 461 : x 19.0 730 3x6rm 7/105 3.08 10 1.25 18 205 860 48 at 3x10m = 7/135 1.83 10 1.25 18 25 1070 “4 56 3x16m 7/471 1.5 10 125 18 25.0 1340 83 B 3x251m 7/214 ODT 12 16 18 286 2000 110 98 3x35sm Min wire 0.524 12 16 18 273 2070 130 120 3x50sm Min 6 wire 0,387 14 16 20 305 2720 155 150 3x70sm Min 12wire 0,268 14 20 24 4S 5 190 190 3x95sm Min 15 wire 0,193 16 20 22 385 4720 25 230 3x120sm Min 18 wire 0.153 16 20 23 420 5650 260 270 3x150sm Min 18 wire 0.124 18 25 25 4707250 295 305 3x185sm Min 30wire 0,0901, 20 25 27 505 8600 330 350 3x240sm Min 34wire 0.0754 22 25 29 566 10800 385 410 3x300sm Min 34wire 0,0601, 24 25 chs 610 13000, 425 470 En a Ensure Qual 48. 123 456 Type: YRGY | 4. Conductor: Copper Standard : IEC-60502-1 2 Insulation : PVG Voltage: 600/1000 volts 3. nner covering : PVC 4, Armour: Round steel wire 5. Helical stee! tape (optional) 6.Oversheath : PVC. Nominal ] No.and | Max.DC Nominal | Nominal | Nominal | Approx | Approx Cross | Nominal | Resistance | thickness | diameter | thickness | overall | weight of [Under ng Sectional | diameter of Cae ea of | diameter | Cable | ground Pca Area of | of Wires | Conductor | Insulation | Armour | Sheath Exe conic Eel iy Sa) i i om 71 0.85 38 7/105 3.08 10 1.25 18 20 950 48 41 4x10m = 7/135 1.83 10 1.25 18 236 1200 4 56 4xi6m 7/171 15 10 16 18 273° 1710 8 B 4x25m 7/244 0.727 12 16 18 3100 2285 10 98 4x35sm —Min6 wire 0,524 12 16 19 30.0 2600 130 120 4x50sm Min 6 wire 0,387 14 20 2a 345 3650 155 150 4x70sm Min 12wire 0,268 14 20 22 395 4730 390 190 4x95sm Min 1S wire 0,193 16 25 24 450 6400 25 230 4x120sm Min 18 wire 0,153 16 25 25 485 7600 260 20 4x150sm Min 18 wire 0,124 18 25 27 520 9100 295 305 4x185sm Min 30wire — 0,0991, 20 25 29 580 11000, 330 350 4x240sm Min 34 wire 0.0754 22 25 Ba 630 13800 385 410 4x300sm Min 34 wire 0.0601 24 25 33 705 17000 425 470 EE bh ‘Type: YRGY Standard : TEC-60502-1 Voltage: 600/1000 volts Construction Contd.) 1. Conductor: Copper 2. Insuiation : PVC. 3 Inner covering : PVC 4. Armour : Round see! wie 5. Helical steel tape (optional) 6. Oversheath : PVC oH 3x25) 7/218 0727 m4 2480 Qx2Ssn/ Mnéwie 05 = 1269s m0 teism 7/371 4st 1x 251m 7/214 0.727 12 Qx7oan Mni2wie 028 14 20,28 asa ixasm 19/153 0512 2x9san/ MiniSwie 019 © 16 «20,2230 sem masa 1x50rm = 19/1.83 0,387 14 2x20sm/ Mniewie 0159 «162525 age] 260 La7orm 19/217 026814 Dx 1s0sm/ Mniowe 01 «18-2526 Salm 28505 Lx7orm 19/217 026814 2x185sm/ Min30Wie 0091 20-2827 560 Sma Yxosm 19/257 019346 2xmOsm/ Min2wie 007 2222529 atm Yxmom 37/203 01s) 46 3x asm Min34wie 0001 242M DOD txasdm 97/237 04218 RBecos SE SE 50 Type: YFGY Standard : IEC-60502-1 Voltage: 600/1000 volts 4. Conductor : Copper 2. Insulation : PVC 3. Inner covering : PVC. 4. Armour : Flat stee! wire 5. Helical steel tape (opt.) on _ 6. Oversheath : PVC. Plain annealed Copper Conductor, PVC Insulated, cores laid up, PVC inner covering, Fiat Galv. Steel wires armouring with ‘or without helical steel tape binder and PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath : BLACK Nominal [ No. and | Max.DC | Nominal [ Nominal | Nominal | Approx | Approx Cross} Nominal | Resistance | thickness | diameter | thickness | overall | weight of [Under Sectional | diameter of | ofround | _ of Cable | ground ‘Area of | of Wires Insulation | Armour | Sheath Earle Coarccas or ens Sra Cia) 3x25 1m : On? . r Z 1650 3x35sm MinGwire 0,524 12 08 18 255 1930 130 120 3x50sm Min 6 wire 0,387 14 08 19 286 2520 155 150 3x70sm Min 12wire 0,268 14 08 20 320 3280 390 190 3x95sm Min 15 wire 0,193 16 08 22 364 4300 25 230 3x120sm Min 18wire 0.153 16 08 23 394 5200 260 20 3x150sm Min 18 wre 0.124 18 08 24 83° 6300 295 305 3x185sm Min 30 wire 0.0991, 20 08 26 470 7600 330 350 3x240sm Min 34wire 0.0754 22 08 28 53.0 9800 385 410 3x300rm Min 34wire 0.0601, 24 08 29 578 11900 425 470 4x25m 7/214 0.727 12 08 18 276 = 2000 110 98 4x35sm Min wire 0,524 12 08 19 291 2430 130 120 4x50sm Min wire 0,387 14 08 20 327 3260 155 150 4x70sm Min 12 wire 0,268 14 08 2A 372 4300 190 190 4x95sm Min 15 wire 0,193 16 08 23 418 5550 25 230 4x120sm Min 18 wire 0.153 16 08 24 45.0 6800 260 270 4x150sm Min 18 wre 0.124 18, 08 26 485 8100 295 305, 4185 sm Min 30wire 0,091 20 08 27 540 10100, 330 350 4x240sm Min 34 wire 0.0754 22 08 3.0 610 12900 385 410 4300 sm Min 34 wire 0,0601 24 08 32 675 15500 425 470 & EE YFGY Type: Standard : TEC-60502-1 Voltage: 600/1000 volts Construction Contd.) Por Nominal Cross Parry roa air 3x25 rm/ or Nominal cee of Wires. fee ceo of ar iecg erica 077 foul care ea rete Nominal es Pre) et Nominal | Approx re eI Sheath creer re nr ay st 4. Conductor : Copper 2. Insulation : PVC 3, Inner covering : PVC 4, Armour : Flat steel wire 5, Helical steel tape (opt) 6. Oversheath : PVC. ir ground Ear i 1x16 1m 1.150 10 3x35sm/ Min6wire 0.524 12 08 18 25 220 130 120 1xi6m 7/471 1.150 10 3x50sm/ Min6 wire 0,387 14 08 19 318 2980 155 150 1x251m 7/214 0.727 12 3x70sm/ Min 12 wire 0,268 14 08 24 370-3900 190 190 1x351m 19/153 0.824 12 3x95sm/ Min 15 wire 0.193 16 os 22 412 5050 25 230 1x50rm 19/183 0.387 14 3x120sm/ Min 18 wire 0.153 16 og 23 450 6220 260 270 1x70rm 19/247 0.268 14 3x150sm/ Min 18 wre 0.124 18 os 24 483 7300 295 305 1x70rm 19/247 0.268 14 3x185sm/ Min 30 wire 0.0991 20 os 26 534 9000 330 350 1x951m 19/252 0.193 16 3x240sm/ Min 34 wire 0.0754 22 08 28 59411150 385 410 1x 120m 37/203 0.153 16 3x300sm/ Min 34 wire 0.0601 24 os 3.0 680 14300 25 470 1x150rm 37/227 0.124 18 EE 52 Type: CONTROL CABLE (YY) —_—_—_=_== 1. conductor: Copper ‘Standard : IEC-60502-1 2. Insulation : PVC. Voltage: 600/1000 volts 3. Inner covering : PVC 4 Ovesheat Pv Construction Plain annealed Copper Conductor, PVC Insulated, cores laid up, PVC inner covering and PVC sheathed overall. Suitable for use in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath : BLACK ro Max.0¢ | Nomi Nominal | Approx nad Resistance } thickness | thickness of | overall Ty org Ces of ea sheath | diameter Pony ‘Area of | of Wires | Conductor | Insulation Eire fearing 5xi5re 7x15 te 08 138 275 16 2 Ox1Sre 1/138 . 08 170 370 3 10 Wx1sre 1/138 121 08 18 75 425 2 9 19x15re 1/138 2a 08 18 202 610 10 7 B7x1Sre 1/138 121 08 18 270 1100 8 5 Sx25re 1/178 741 08 18 142 290 4 19 7x2Ste 1/178 741 08 18 153 370 2 ” 10x25re 1/178 741 08 18 190 507, 18 4 Wx25re 1/178 241 08 18 194 570 16 13 19x25re 1/178 741 08 18 25 835 14 2 37x25re 1/178 241 08 19 30.0 1530 9 7 EE 53 ‘Type: CONTROL CABLE (YRGY) de 4. Conductor : Copper Standard : IEC-60502-1 2. Insulation : PVC. Voltage: 600/1000 volts 3, Inner covering : PVC 4, Armour : Round stee! wire 5. Helical steel tape (opt.) 6. Oversheath : PVC. Construction Plain annealed Copper Conductor, PVC Insulated, cores laid up, PVC inner covering, Round Galv. Steel wires armouring with ‘or without helical steel tape binder and PVC sheathed overall. Suitable for use as control cables in indoors, outdoors, underground and in water for continuous permissible service voltage of 720/1200 volts. Colour of Sheath : BLACK Nominal No. and | Max.DC | Nominal [ Nominal | Nominal | Approx | Approx Cross | Nominal | Resistance | thickness | diameter | thickness | overall | weight of [Under Sectional | diameter Cae ei cl Pot ta eas Insulation | Armour Ean ears rid Sra Cia) xis E 12.1 r y x : 545 7xiSte 1/138 124 08 1.25 18 175 620 16 2 OxiSre 1/138 124 08 1.25 18 207 805 3 10 wxisre 1/138 12a 08 125 18 25 885 2 9 19x1Sre 1/138 at 08 16 18 25.0 1280 10 7 Maxisre 1/138 2d 08 16 18 278 1510 9 6 BxiSre 1/138 124 08 16 19 3121960 8 5 5x25re 1/178 741 os 1.25 18 18.0 650 24 19 7x25re 1/178 741 08 125 18 19.0 750 aa v7 Wx25re 1/178 741 08 1.25 18 25 980 18 4 Wx25re 1/178 7.41 8 1.25 18 3.0 1060 16 3 19x25re 1/178 7241 08 16 18 269 1560 4 2 24x25re 1/178 741 08 16 19 306 1880 3 u 37x25re 1/178 241 08 16 20 3452480 9 7 Ensure Qual

You might also like