’ SIEMENS 7SK88 Static single phase inverse time overcurrent relay Order No. £141/247-101 (4) £14041-F7230-U21 1-82-7600, SIEMENS 6 7 SK 88 Static single phase inverse time overcurrent relay rotary link Test sockets current setting Jp Contact pin — Time multiplier Indicator J> High set J>> Indicator J>> Reset (UVF 140 1-F 7930.0 11714-77600, © Contents ee cel Oe 10. "W, 12, 13. Application Characteristics Principle of measurement Internal Internal External External operated block diagram, d.c. supply Dlock diagrem, c.t. supply connections, d.c. supply or c.t. supply connections, c.t. supply and or c.t. trip coil Auxiliary supply Current transformer selection Design Setti. g the relay Overcurrent element I> Current setting I, Time multiplier (TM) Current time characteristic High set instantaneous elment I>> Acceptance check Commi ssioning Functional ‘testing wi h test ‘set ‘7VP461 and timer B2041 (-7KB2041) Maintenance Installation and dimensions Diagrams of burden and thermal withstand capability Technical data Ordering code (MLFB) Runa a we woe ar Ia 10 15 7 18 20 21 22 24 29 33 (4) B14043-F7230-U211-A2-7600 iG 1. Application The single phase inverse definite minimum time overcurrent pro- tection 75K86 is installed for the main protection of radial cir- cuits in medium voltage networks and industrial installations and as back-up protection, The version with current transformer supply allows the application in installations where no station battery is available. The 7SK88 can be supplemented by the directional relay 7SP88. This combination provides a directional inverse time protection system for the protection of ring mains and parallel lines with single end infeed or parallel transformers (details in description 7SP88). 1.1 Characteristics © The 7SK88 contains the overcurrent element I> with a dependent current time characteristic. As an optional supplement, a high set instantaneous element I>> can be provided. * Operations for tripping due to overcurrent I> and for short- circuit instantaneous tripping due to high set element I> are indicated on separate indicators with storage function. ° The apparatus can be supplied with the characteristic: Normal inverse as per BS 142, very inverse or extremely inverse. ° The auxiliary supply voltage is connected directly +o the terminal studs. A version with current transformer supply is possible. * Because of the phase segregated of construction, the protection in the other phases remains in service during testing of an element of the protection. Furthermore, the faulted phase is indicated. The static inverse time overcurrent relay also provides © lower current transformer burden e practically no overshoot (4) B14043-27230-U211-42-7600 © limited maintenance © increased shock insensitivity © Testing The testing can be easily performed by a test adapter and a por- table test set. The primary current is without any influence on the test procedure. Principle of measurement The current from c.t. is led to the terminals 3 and 4. The setting © of the operating value I, is selected on the frontplate. The current is converted into a proportional d.c. voltage in the measuring in- put circuit. When the set value I, is exceeded the function gener- ating network I = f(t) will be released to provide the requested dependent current time characteristic. After the allocated time delay the tripping relay A and indicator I> are energized. In case of high short circuit currents the hich set current indi- cator I> is operated at a multiple of .the I, setting (I> 71) and instantaneous tripping is occurs (without Br. 2, without C12 Capacitor 012 delays the instantaneous tripping, Br. 2 blocks I> . In planning the tripping circuits, ensure that the rating of the ~ output relay contacts are not exceeded. supply, The auxiliary supply voltage is lea to terminal 9 ( L+) or terminal 7 (if 220 V model is used) and terminal 8 ( L-). The 220 V model is fitted with a dropper resistor which is located at the main terminals for good heat dissipation. The resistor can attain a sur- face over-temperature of 200°C - it must be ensured that the resul- tant heat can properly dissipate and is not obstructed by adjacent wiring or other restrictions. If the indicator shows "tripped", it can be reset on application of the auxiliary voltage. (4) £14043-F7230-U211-A2-7600 o c.t. supply A saturation c.t. is provided to deliver a smoothed secondary voltage for the power supply of the internal circuitry. With current transformer supply the indicators can be reset, when at least 20 % load current flows in the primary circuit or with an auxiliary voltage (Up...4 t~ ). 2.1 Internal block diagram d.c. supply y 7SKa8 - - ” 7 nomossc1 ta) is LL aux. %o Le ferry & suppiy 7 5 Us Te Mi % Anschlu KL7 und Widerstand Rp nur bei Uy = 220Vdc Conn. terminal 7 and resistor Rp only model with UH = 220Vdc Ro= WeKi7 TW (n= 220vdC © (4) B14043-¥7230-U211-A2-7600 2.2 Internal block diagram, c.t. supply, sea PRUEFSTAOMARSCHLUSS: STECKER PLUG ial 1 mea. IE eb JplA i ‘4 a meee = SE sn 4 oo const. " dee THiKe. Wreset _ 12 be deed 2} ao nett ! rd . . . . a j Uieset IVI Wee WOE] Dora] wae | Hac] TW /AsIac Rp (kit ] 2 IW. 15 3,6 10 0 2h 75 Cc 9 (4) B14043-P7230-U211-A2-7600 2.3 External connections, d.c. supply or c.t. suppl: Ley de aux. bus 97 i947 [oq7 [oq7 *] ed v lnskes| |7skee| |7skee} |7sKae| 8 8 8 IS al] ke — 413091 terminal 7 for 220V model 413051, auxiliary supply connections current connections {not applicable to version with ct. supply) wy alarm auto - reclose 7 relay or similar * see 2.4 f or alarm + [E 413091 by output contact connections (4) £14043-F7230-0211-A2-7600 t 2.4 External connections, c.t. supply and c.t. operated trip coil auxiliary ct 4AM 5065-2CB (1A) 4AM5070-BAB (SAI 0 a : TSK 8B [Kb agit Ke eee 7ske8” #43) oskae** kd Comm Ud 3] 4 7SK 8B ka 613050 01,02 : Zenerdiode 1N 28248 of 1N3325 B 33 Vi5%/ SOW (SIEMENS, MOTOROLA, THOMPSON) mounted on cooling ribs, e Rane 1° CW e.g. KS125-100-£ (Fa, Austertitz) 2 R : 472/50W ect. trip auxiliary ct SAM 5065- 2CB (1A)and 4ANSOIO -BABI5A) Jrat. terminal_links secondary connections 058 Ub=Ke; to -kb ka = Ib ta Lb-Ke ka-la * Optional x residual current elements are shown for completeness but this circuit is applicable only if the earth fault current exceeds rated relay current. (or 5A respectively) (4) B14043-F7230-U211-A2-7600 A The relay measuring element requires a d.c. supply (see survey of types, section 13). With c.t. supply an additional internal circuit powers the mea- suring element from the c.t. secondary current. An auxiliary d.c, supply is still required for the circuit breaker trip coil. As a further alternative,current transformer supply plus c.t. operated trip coil for exawple Siemens type 3AX11(H86w), can also be operated when an auxiliary supply is not available. An auxiliary c.t., with saturation characteristic, type 4AM5070-8AB or 44M5065-2CB, connected in the c.t. circuit as shown in section 2.4 gives the required power (up to 20 VA at 0.5 or 1A). For reliable operation adequate primary current (greater than c.t. rated current) is necessary. Thus, this method is not suitable for earth fault tripping if the earth fault current is less than full load current. In such cases an auxiliary supply is essential. 4. Current transformer selection The nominal admissible size of the c.t. can be determined by the rule that a steady-state a.c. short circuit current up to the set value I> (pick-up value of high set element) can be transformed without saturation taking into account the actual total c.t. burden. I>> pick-up value of high set element a rat rated current ALF accuracy limit factor The phase overcurrent relay has a very low burden. Thus, as a gener- al rule, @ 15 VA 10P10 (knee point voltage >190 V for 1 A resp. 38 V for 5 A transf. second rating) transformer is sufficient. In many cases, a lower output will suffice. This can easily be checked by the general principles applying to the calculation of c.t. bur- dens. (4) £14043-P7230-U211-a2-7600 When used as a ground fault protection relay, the low burden cha- racteristic allows the relay to be set at the very sensitive cur- rent level of 0.1 - 0.4 x trated even when used with c.t.'s of standard output. If the trip coil has to be operated by c.t. 4AM5070-8AB for 5 A vated current or 4AM5065-20B for 1 A rated current a minimum c.t. output of 30 VA 10P10 is required. Example: ootes 200/1A, 15 VA 10P10, Py = 3,75 VA (25 # internal ” burden) Relay: Ph: Setting range 1 to 4 A, setting I, = 1 Ay Te = 15 x I, for phase faults Bt Setting range 0,2 to 0,8 a, setting I, = 0,2 A, Im= 15 x 1, for earth faults 2 > xt. ib x4 5 phase faults: ALP > t=, = “)tip- 2+ = 15 The burden is given on page 25 for T/trat ae ee Php = 0924 VA PB = Phy + Poonauctors (2esumption 0,5 VA) aupe n. Prt Pa 2 10 19+ 3:79 2 41,7 Po + Py 0,74+3,75 9 (4) B14043-F7230-U211-A2-7600 : ye Loomee ee bee Onan earth faults: ALP » E> =. 02 _ The burden is given on page 24 for I/;,4, = 3 Py 4 VA for 78K882 Pop = 0.27 VA for 7SK884 Poo = Pi +P +P ump ti 0,5 VA Ebte Sl as condueters) Gaceee ene) ALF 2 190 12+3,75 _ 29 4,7743,75 The c.t. is sufficiently dimensioned. 5. Design The synthetic material case is designed for switchboard panel flush mounting. It corresponds to the protection class IP54 (terminals IP04). The module carrier with input current transformer and auxiliary supply is built as a slide-in unit and is screwed to the case. The module with the active part is withdrawable (i.e. a plug-in unit). On removal of the front cover the current transformer termi- als are automatically shortcircuited and all setting elements accessible to touch are made potential free. Electrical connec— tions are made via studs on the rear of the apparatus. All setting elements and indicators are visible through the transparent front cover. Resetting of the target indicators is effected from external. (4) £14043-F7230-U21 1-42-7600 -10- Setting the relay 6.1 Overcurrent element I> Remove front cover by releasing captive screws top and bottom. Removal of the cover automatically short circuits the input from the associated current transformer and disconnects it from the internal circuits and the tripping and alarm circuits are inter- rupted. Thus the accessible components on the relay front are entirely volt-free, When used for phase overcurrent protection, one or two further 7SK88 relays are installed in the remaining phases. These remain operative. = The overcurrent element I> has two settings: 6.1.1 Uurrent setting I, Ip (plug setting) can be selected in one of the following ranges. 0.1-0.4A, 0.2-0.8A, 0.5-2A, 1-4A, 2,5-10A, 4-16A in 7 equal steps by a rotary link on the front plate. These setting values on the front plate are given in amps. The two screws must be re-tightend carefully. The link must not be left in an open position. This setting allows the overcurrent tripping to be selected with res- pect to circuit rated load and current transformer ratio. . a e.g. c.t. ratio 200/5 A . circuit full load current 120 A required overcurrent tripping 1.25 x full load (for example) current relay range 2,5 to 10a eee rook 75) a P 200 Nearest setting = 3.75 A (4) B14043-F7230-U211-A2 -7600 -11- 6.1.2 Time multiplier (1M) Set by slotted rotary dial on the front plate; two ranges are available: 0.05 to 0.5 in steps of 0.05 (with red selector plug on PCB in position I ~ as set in the factory), alt. 0.55 to 1 in steps of 0.05 (with red selector plug on PCB in position aaa The adhesive strip for the TM scale situated on the rear of the front plate must also be removed and fixed on the front to cover the printed letters TM into TM + 0.5. Thus the alteration of the IM~setting range is made visible. The TM-setting allows selection of the time scale against which the inverse characteristic is set. The intermediate curves given by the 0.05 steps lie between the curves shown. The recommended grading time between successive relays is 0.3 to 0.4 sec. 3 Current time characteris The current time characteristics t = £(1/1,) for the inverse time overcurrent relay 7SK88 are shown on page 12 to 14. I: Current in A I,: Current setting in A 1: Time multiplier adjustable on front panel, as per BS 142 The current time charateristic of 7SK88 is designed according BS142. The relay must not pick-up below 1,05 x setting. The curves are not defined acc, BS142 between 1,05 to 2 x setting. About this demand the curves of 7SK88 are defined from 1,5 x setting. In the range between 1,15 to 1,5 x setting the relay 7SKB8 is certainly tripping ,but the tripping time is not defined and different from the relay. (4) B14043-F7230-021 1-42-7600 man aad 0.8 06 04 03 0,2 0.1 0,08 0,06 0,04: 0,03 0,02 41607 ~12- normal inverse (to BS 142) 9 iB a 0 2 Ip ——> 0 (4) B14043-F7230-U211-A2-7600 -13- very inverse 01 0,08: 0,06: 0,04 0,03 0,02 0.01 05 1 2.53455 10 20 60s Ip. ——* (4) £14043-F7230-U211-A2-7600 ae extremely inverse 01 0.08: 0,06 0,04 0,03: 0,02 0,05 05 1 2.345 10 20 41606 Ip - a (4) E14043-F7230-U211-A2-7600 a5- PCB TH range E fe indicator aay a Relais Relay Relais FE of st 1 Si 4A er30% withdrawable printed circuit board TM+0,5 (adhesive strip! eh 05-05 -/ \- -/ 7 \- mA 55° 1-0 - =f] 005 S—<“s05 9.05 S05 4/3022 0054005 3022 05 tot cecal (as delivered) (altered | TM range TM setting range red selector plug (4) £14043-F7230-U211-A2-7600 -16- 6.2 High set instantaneous element I> When fitted, is set by slotted rotary dial on the front plate: The setting is stepless. Range: 4 to 20 times 1, e.g. if I, set at 3.75 A = 125 % circuit full load current (as in current setting example) and I>> set on 10, then instantaneous element operates at 37.5 A (12.5 x full load current) within approx. 15 ms. If the operating time proves to be too short, it can be extended by inserting a capacitor, on the solder tags marked C12 on the printed cireuit board. A dry type tantalum capacitance is recom— 4. mended (e.g. Siemens B45265 with at least 35V d.c. and tolerance + 10 #). The required capacitance for a particular time delay is given in the following diagram. If the solder bridge Br.2 is inserted on the PCB then the tripping from the high set element I> is blocked (as delivered the bridge Br.2 is not inserted). (4) B14043~-F7230-U21 1-42-7600 -17- sonTea soueqtoedeo auq 0% peyeted KeTep suTT «I yUeusTe snosuEyuersUT 498 YPTH 3 4 z @ (44) 212 ¢pHzDdoy (4) B14043-P7230-U211-A2-7600 -18- Acceptance check On unpacking the relay, check the nameplate to ensure that the model number and rating agree with the requirements. Check that there are no signs of physical damage. The relay is thoroughly works-tested and calibrated. It contains no moving parts and is therefore ready for installation without adjustment. If the indicators show "tripped" (red) when delivered, this is unimportant since it can be reset as soon as the auxiliary supply voltage is connected or, with supply from c.t., when at least 20 % load current flows in the primary circuit. It has to be noticed that the ordering code of the front cover and rating plate are equal. . (4) B14043-F7230-U211-Aa2-7600 0 -19- Commissioning At first, check that the connections of current transformers, tripp~ ing- and alarm connections as well as the polarity of the auxili- ary supply are correct: a) Check ratio and connections of c.t.'s Check auxiliary supply voltage and polarity ») . Check reponse of relay at your settings: CAUTION: When removing or restoring connections, the accepted safety practices and regulations must be observed. During all measurements take care that the thermal withstand capability is not exceeded (see section 11). b1) Remove transparent front cover, The external c.t. is auto- matically short-ciruited and disconnected from relay. b2) Use the original test plug with the associated cable 7XV81 (which includes the tripping circuit output - see section 8.1) Check the operating time at one or two points on the charac- teristic, one with a test current of approximately four times plug setting and one at a higher value if possible (Siemens test sets 7VP44 or 7VP461 may be used for this purpose). The permissible tolerance should not exceed t 20 % (according to BS 142). Should larger tolerances exist then, as a first step, it should be checked: - superimposed load current | not possible if 7xv81 - shunt circuit for test current is used for testing - test current not constant during relay delay time - test current not injected (in particular for relay with c.t. supply). (4) £14043-F7250-U211-A2-7600 -20- - test current not sinusoidal > The testing set doesn't deliver an impressed current. With e.t. supply there are greater tolerances because the test current wave form may be disturbed as a consequence of the non-linear burden of the saturation transformer. You can get a correction with current of a source with impressed current or with higher voltage and greater series resistor. If,after checking the above points an excessive tolerance exists then the complete relay should be returned for repair. Do not attempt recalibration. 3) The reponse of the high set element may be similarly checked. The permissible tolerance should not exceed t 10 #. * A steady state testing is, as a rule, not possible because with slow control the thermal withstand capability of current circuit may be overloaded. ce ) Check correct functioning of tripping circuit (with circuit breaker if possible) and indicating circuits all in conjunc- tion with directional relay 7SP88 if fitted. a ) Restore equipment to proper operating condition. Important: - After testing the relay it is essential that the correct type of plastic front cover is refitted. Check that the cover has the engraved type designation 7SK88**_**, (4) B14043-F7230-U211-A2 -7600 8.1 Functional testing with test set 7VP461 and timer B2041 0 semen ret ¢ (TKE2041) 126, 543 I 7XV 8110 7xV 8120 | |) Le. be relay input ct y- yellow | b blue br & | 6 black ! green | 4 Banana plugs ‘Harting plug | 1ske8 . : -evicton NOM cantec st, | ‘i308 ae T TH] i: green. brown white\ yellow aaaa ||| ac) Gj Test current injection ma {ineras aur response time | 7 measurement ety Ac meiten TxvB120 ¢ a) 8 A time measurement according to this R) nethod is without Mains deviation 380/220) 10VE \Reset Timer 8 2041 By (4) B14043-P7230-U211-A3—76¢ ~2a- Q. Maintenance The unit has no particular maintenance requirements. All mea- surement circuits are static and maintenance free. The tripping relay is covered with a transparent protective cover. An occasional functional test is recommended. The tripping circuit and circuit breaker should be included in the test, together with any associated elements (e.g. 7SP88 directional relay). In the event that a component becomes damaged or unservicable the complete PCB or assembly can be easily replaced without re- calibration. Note, that then the tolerance could be greater . than 2% above the specified tolerance. (4) B14043-F7230-U211-A2-7600 -23- The following standard replacement parts are available: Deseription Ordering Code @ransparent front cover €73207-4235-B66 Printed circuit board (complete) Measuring element normal inverse ©73207-A235-B221 very inverse 073207-4235-B225 extremely inverse | €73207-A235-B227 with high set element normal inverse 073207-A235-B222 very inverse 073207-A235-B226 extremely inverse | €73207-A235-B228 Important: These replacement parts only apply for the relay type 7SK8B**—**A In the case of relays of an earlier series the complete relay must be returned for repair. 40. installation and dimensions The case is designed for flush mounting in a panel or support plate of any convenient thickness and at any convenient angle in a location reasonable free from excessive heat, dust and moisture. It can be secured by two machine screws (M6), with nuts, top and bottom of the front bezel. External connections are at the rear. These are post type ter- minals fitted with slotted head screws and clamps. Felxible or stranded conductors must be fitted with crimped ferrules. All terminals are permanently numbered. For front-access-only cabi- nets, the relays can be mounted on hinged plates or frames for access to the terminals. The internal carrier is secured by screws from the back and supports the plug-in printed circuit board on the right hand side which carries the static component circuitry. (4) B14043-P7230-U211-A42-7600 -24- Dimensions A -——0 $7 Z ~" | r q | al oH eal poe foe low || z 2], | | |alslalel | a |" Dib | | Ley | | A | = : U fh] | 2 177 lb — 126. Mounting holes 7mm dia or MB Panel cut-out M25 (4) 14043-F7230-U211-A2-7600 -25- 6 11," Diagrams of burden. and thermal withstand capabilit: Plva__eefered to Jeot 3381 ee" ars & 203 0s 678en | 1% OD Tim Burden of 1A- relay, d.c. supply, dependent on fault current, referred to Jrated = 1A A= Setting range 01.....068 —-— Setting range 0,2.....084 Setting range 0,5.....2A Setting range 1... (4) B14045-P7230-U211-A2-7600, =26- : PLVAL_refered to Jrat uzss0 2 03 geos. t Er er) Lie wunest oq i asyawapia 1? oes : & eaRE! Hf 3 44 é as a Burden of 5A-relay, dc.supply, dependent on fault current, referred to Jrated = 5A oo Setting range 0,5.....24 —-— ‘Setting ronge 1 -2...4A Setting range 2,5... 108 Setting range & ...16A 9 (4) B14043-F7230-U211-A2-7600 2 Oa) i 3b esaael Burden of 1A -relay, ct supply, dependent on toult current, u referred to Jrated = 1A A= Setting range 01....068 —-— Setting range 02... 084 —— Setting range 0.5.....24 Setting range 1 .....4A (4) B14043-P7230-U211~A2-7600 PIVAL refered toJeat 02 93 qeas ws9y a ya 10? 3 Staal ede Burden of 5A-relay, ci. supply, dependent on fault current, referred to Jrated = --— Setting —-— Setting Setting Setting 5A range range range range os 1 25 4 240 4A 108 168 (4) B14043-¥7230-U211-a2=7600 9 Pe Thermal withstand capability of current circuit (4) B14043-F7230-U211~-A2-7600 -30- 12. Technical Data Input circuit Rated current Inateq Tor5a Rated frequency frateg 50 to 60 c/s Rated burden in the current circuit see section 11. c.t. supply and c.t. operated trip coil 30 VA minimum Thermal withstand capability for 1 second (I, = current setting) 100 x Ipmin (max. 250 A) for 10 seconds 30 x Ipmin (max. 75 A) continuously 5 x Ipmin (max. 16 A) d.c. supply Uy 48, 60, 110, 125, 220 V Operative range 0.8 to 1.15 x Uy 0.85 to 1.15 x Uy (4gV model) Power consumption 48 sat 60 V | 110 ¥ unenergized 2.9W energized 2.9W 220 V max. perm, residual ripple 10 % Overcurrent element I Current setting I, 0.1 - 0.4 A a 0.2-0.8 A 0.5 - 2.0 A 1 -4 A 2.5- 10 A 4-16 A Minimum step 7 current tappings at equal intervals pick-up value 1,05 - 1,15 x I, P (4) £14043-F7230-U211-a2-7600 © eae pick-up time at drop-out time at 2 x1 3 Tolerance Influence quantities due to change in temperature of 10 K in the range of -5°C to + 40°C on change of auxiliary voltage between 80 % and 115 # Uy on change of frequency of 48c/s to 62 c/s drop-out/pick-up ratio Overshoot time ca. 10 ms ca. 35 ms 5% 6 # for setting ranges 2.5 - 10 A and 4-16 A exept final value 12 % for final value 16 A t es + " TAL " TAL " TAL ° +95 2 ms " High set instantaneous element I> current setting pick-up time at 1.1 x setting 2 x setting with time delay (additional capacitor (12 on PCB) Tolerance drop-out time drop-out/pick-up value 4x to 20 x setting I, (stepless) 20 ms 15 ms 50 to 400 ms = 10 % of setting ca. 40 ms(without add. capacitor 012) ca. 0.90 (4) £14043-F7250-U21 1-42-7600 -32- Influence quantities due to change in temperature of 10 K in the range of -5°C to + 40°C on change of auxiliary voltage between 80% and 115% U,; on change of frequency 48c/s to 62 c/s w 1% setting 1" 1% setting " 2% setting Timer Time setting consistency of tripping time Influence quantities due to change in temperature of 10K 5241 in the range of - 5°C to + 40°C on change of auxiliary voltage between = 2 % I 80% and 115% Uy on change of frequency of 48 c/s to 62 c/s Tripping relay A, B Number and type of contacts, each Material of contact limiting cycling voltage Limiting continous current Limiting short-time current Limiting making capacity limiting breaking capacity inverse time characteristic normal inverse very inverse extremely inverse see section 6.1.3 TM: 0.05 to 1 in steps of 0.05 according to BS 142 to.5 # (IA, ® 2) v Pp S141, miniature relay B 2 make contacts Ag-Cd-oxide 250 V 5A 30 A/0.5 5 1000 VA 30 VA L/R = 40 ms (4) £14043-F7230-U211-A2-7600 C Case Weight, approx. 1.5 kg, c.ts. supply 1.8 kg Material Makrolon, fibreglass reinforced Colour Stone grey, RAL 7032 Connections 13 studs on the rear of the case Test voltage Impulse voltage withstand test High frequency cisturbance test Ambient temperature during operation in transit during storage Humidity class index acc. DIN 40040 Mechanical withstand acc. DIN 40046 for operation for storage and transport Degree of protection Specifications or recommenda- © tions 2 kV, 50 Hz, external circuits against each other, 1 min. against internal circuits and against earth 5 kV, 1.2/50 us as per IEC 255-4 external circuits against each other, against internal circuits and against earth 2.5 kV, 1MHz, t = 15 us 400 pulses/sec. as per IEC 255-4 °c to + 40°C -25°C to + 70°C -25°C to + 55°C P = 75% average 95% for max. 30 days p.a 10....60c/a; 0.035 mm extentricity 60...500c/s: 0.5 g 5.ee+..8c/s: 7.5 mm extentricity eee Ip54 (terminals IPo4) ace. TEC 144 IEG 255-4, VDE 0435, BS 142 (4) £14043-F7230-U211-A2-7600 13, Ordering_code MLFB 7s 818 - A 1... ObA 1A 1 02... OBA 1A 2 | Setting ranges Jp 05... 2A tAand 5A [3 | rated current 1 4A tAand SA |G | 25...10 A SA 5 - 4.1.18 ASA 6 dic. supply Tey) 7 ov 2 Auxiliary supply uy 2 ra 4 220 5 ct supply 8 corrent time normal inverse acc. to BS 142 [1 characteristic a 2 extremely inverse 4 High set instan- without J> o foneaus element Jo» | with Jo>, 2 tripping relays E Test A Test adapter for 7SK 88 7XV8110 Test adapter cable with banana plugs 7XV8120 Test adapter cable with Harting plug for testing with 7VP461 (4)£16061-F7230-U211- A2~ 7600 -35- Continuous technological progress and modernisation of compo- nents may necessitate production modifications. These modifi- cations do not affect relay performance and are recorded, for internal purposes only, by two letters after the ordering code (e.g. 75K8818-1DA/DD). Untill 1.4.81 were following versions delivered without test sockets: 7SKe8**-*A without I» , with 1 tripping relay 7SK88**-*B with I= , with 1 tripping relay Cc 7SK8B**-*C with I> , with 2 tripping relays (4) B14043-F7230-U211-A2-7600,

You might also like