You are on page 1of 2

iSens-P vMonitor TM

Creating the Digital Oilfield


Wireless Pressure Sensor

Sensor

• FM-approved and CSA certify for Explosion proof for Class I


Division 1 hazardous locations
• ATEX-approved Flameproof for II 2G Ex d II C
15.40
• EMC directive 89/336/EEC emission (class B) and immunity
according to EN 61 326
Stainless steel

Pressure ranges in bar

Response time in milliseconds ≤ 1 (≤ 10 ms at medium

temperatures below -30 °C for pressure ranges up to 25 bar 16.0
or with flush diaphragm) 7.30
Accuracy % of span ≤ 0.25
• Permissible temperature -30 ... +100 °C {-40 ... +105 °C} -22 ...
• +212 °F {-40 ... +221 °F}
Shock resistance g 1000 according to IEC 60068-2-27
• (mechanical shock)
Vibration resistance g 20 according to IEC 60068-2-6
(vibration under resonance)

1.5

Pressure Range Antenna

• Hazardous Area Explosion Proof Antennas with Gain


Range 25 40 60 100 160 250 400 600 1000 2DBi
• Certifications UL listed for the following locations:
Over Pressure 50 80 120 200 320 500 800 1200 1500
Class I Div 1, Groups C, D -40oC ≤ Ta ≤ +85 oC, Class I
Burst Pressure 96 400 550 800 1000 1200 1700 2400 3000 Zone 1 AEx d IIb T5, Ex d IIB T5 -40oC ≤ Ta ≤ +85 oC. CE
0539 II2G Exd IIB T5, DEMKO 08 ATEX 0727941X (see
documents 35105 and 35106 for safe installation)

Connection Type Certification

G 1/2 G 1/4 1/2 NPT 1/4 NPT • FM-approved and CSA certify for Explosion proof for
per Nominal class1, Division 1, Groups A, B, C and Dust-Ignition
EN 837 EN 837 per Nominal proof for class II/III, Division 1, Groups E, F and G;
Order code: size for US for hazardous (Classified) Locations, indoors and
Order code size for US
outdoors.
GD GD Standard Standard
tapered pipe tapered pipe

Abu Dhabi, U.A.E. - Tel: +971 2 6767 965, Fax: +971 2 6767 956, Houston, TX, U.S. Tel: +1 713 467 3900, Fax: +1 281 888 7626
info@vmonitor.com

© 2011 vMonitor, LLC, all rights reserved www.vMonitor.com