General specification

Project description
Project No.: 1 Date: 2021-08-15
Project title: IX
Project subtitle:
Remarks:
Customer
Name: Phone:
Location: Fax:
Contact: Mail:
Designer
Name: nrc Phone:
Location: Fax:
Contact: Waldo Olsen Mail: 20160517@hti.edu.eg
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 2/12

Module specification

Gross throughput: 62.50 [m3/h] Number of lines: 1


Running time: 12.00 [h]
Gross water volume: 750.0 [m3]

Notes and warning messages

- Water analysis: Low Carbonic hardness content.


- Dimensioning: The OEM is responsible for the construction parameters of the plant.
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 3/12

Water analysis of feed  Date of sampling: 2021-08-15


Water source: wadi
Water type: Municipal potable supply (SDI less than 5) Country: Egypt
Source flow rate: 62.50 [m3/h]  

Cations Original Unit [mg/l] [meq/l] Anions Original Unit [mg/l] [meq/l]
Na 481.70000 [mg/l] 481.70000 20.95259 Cl 730.33000 [mg/l] 730.33000 20.60169
Ca 188.03000 [mg/l] 188.03000 9.38273 SO4 510.31000 [mg/l] 510.31000 10.62482
Mg 65.89000 [mg/l] 65.89000 5.41859 CO3 1.11146 [mg/l] 1.11146 0.03705
K 17.00000 [mg/l] 17.00000 0.43478 HCO3 277.47000 [mg/l] 277.47000 4.54720
Sr 0.00000 [mg/l] 0.00000 0.00000 NO3 0.00000 [mg/l] 0.00000 0.00000
Ba 0.00000 [mg/l] 0.00000 0.00000 F 0.00000 [mg/l] 0.00000 0.00000
NH4 0.00000 [mg/l] 0.00000 0.00000 SiO2 0.00000 [mg/l] 0.00000 0.00000
Fe(II) 0.00000 [mg/l] 0.00000 0.00000 B 0.00000 [mg/l] 0.00000 0.00000
Mn 0.00000 [mg/l] 0.00000 0.00000 PO4 0.00000 [mg/l] 0.00000 0.00000
Al 0.00000 [mg/l] 0.00000 0.00000 Br 0.00000 [mg/l] 0.00000 0.00000
  As(III) 0.00000 [mg/l] 0.00000 0.00000
  As(V) 0.00000 [mg/l] 0.00000 0.00000
0.00000 [meq/l]   0.00000 0.00000 [meq/l]   0.00000
0.00000 [meq/l]   0.00000 0.00000 [meq/l]   0.00000
H+ 0.00003 0.00003 OH- 0.01193 0.00070
Sum C 36.18869 Sum A 35.81076
+ Na 0.00000 0.00000 + Cl 13.37384 0.37726

Others     Summary
Temperature 25.00 [°C] Turbidity 0.00 [NTU] Fe (total) 0.00 [ppm] TDS 2285.22 [ppm]
pH 7.60 SDI 0.00 Free chlorine 0.00 [ppm] Conductivity 3683.33 [µS/cm]
CO2 9.31 [mg/l] TSS 0.00 [ppm] H2S 0.00 [ppm] Osmotic pressure 139.50 [kPa]
TOC 0.00 [ppm] Ionic strength 0.049
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 4/12

Comments
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 5/12

Resin selection and regeneration parameters

Resins Softening
Component SAC
Resin type S 1567
Safety factor 1.00
Decarbonator No

End point  
Average hardness leakage [meq/l] 0.0073
Hardness at end point [meq/l] 0.0700

Regeneration parameters Softening


Regenerant NaCl
Specific consumption [g/l] 90.00
Specific consumption [% Th.] 0.00
Concentration as supplied [%] 100.00
Brine concentration [%]  26.00
Dilution and rinsing   with treated water
Progressive regeneration No
  1. Dilution 2. Dilution
Concentration as applied [%] 8.00
Portion [%] 100.00
Amount [kg 100%] 936.00
Volume as supplied [l] 441.51
Volume as applied [l] 11082.66
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 6/12

Plant dimensioning

Step Softening
Process Fluidized bed
Component SAC
Resin type S 1567
Active resin volume (as delivered) [l] 10400.00
Ionic load [meq/l] 14.80
Ionic load per cycle [eq] 11100.99
Installed capacity [eq] 11101.11
Operating capacity [eq/l]  1.07
Specific flow rate [BV/h] 6.01
Filter diameter [mm] 3200.00
Wall thickness [mm] 13.00
Thickness of rubber lining [mm] 1.00
Cross flow velocity [m/h] 7.91
Resin volume (delivered) [l] 10400.00
Max. total bed depth [mm] 1316.06
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 7/12

Filter dimensioning

Step Softening
Process Fluidized bed
Component SAC
Resin type S 1567
Total resin volume (as delivered) [l] 10400.00
Swelling rate [%] 0.00
Total resin volume (inert) [l]      IN42 1185.35
Filter geometry  
Filter area [m2] 7.90
Minimum cylindric filter height [mm] 1500.00
Total pressure loss [kPa] 14.22
Cross flow velocity [m/h] 7.91
Filter compartment  
Pressure loss [kPa] 14.22
Resin volume (inert) [l] 1185.35
Resin volume (as delivered) [l] 10400.00
Freeboard ratio [%] 2.58
Freeboard [mm] 33.94
Bed depth (inert) [mm] 200.00
Max. total bed depth [mm] 1316.06
Bed depth (resin as delivered) [mm] 1316.06
Bed depth (resin regenerated) [mm] 1316.06
Bed depth (resin exhausted) [mm] 1316.06
Minimum cylindric height [mm] 1500.00
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 8/12

Regeneration Softening (Fluidized bed)

SAC     Velocity Rate Time Volume Volume


S 1567   [m/h] [m3/h] [min] [m3] [BV]
Injection NaCl 8.00 % 5.00 39.51 16.83 11.08 1.07
Displacing 3.65 28.88 43.22 20.80 2.00
Fast rinse 10.00 79.02 15.79 20.80 2.00

Total service water: 90.84 52.36 5.04


Total waste water: 52.68 5.07
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 9/12

Net production and waste water

Net production Softening


Net capacity [m3] 697.64
Net flow rate [m3/h] 58.14

Waste water composition  

Cations [eq] [meq/l] Anions [eq] [meq/l]


TH: 11100.99 210.71 Cl: 17121.65 325.00
Na, K, NH4: 6042.18 114.69 SO4: 559.74 10.62
Other cations: 0.00 0.00 HCO3: 251.68 4.78
SiO2: 0.00 0.00
Other anions: 0.00 0.00
Note: The waste water composition depends on the reliability of the water analysis.

Regenerants Total Spec. consumption


[eq] [kg 100%] [kg/m3]
NaCl 16016.43 936.00 1.248
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 10/12

Water composition of final product

Cations [mg/l] [meq/l] Anions [mg/l] [meq/l]


Na 821.81564 35.74666 Cl 757.07768 21.35621
Ca 0.09212 0.00460 SO4 510.31000 10.62482
Mg 0.03228 0.00265 CO3 1.11146 0.03705
K 17.00000 0.43478 HCO3 277.47000 4.54720
Sr 0.00000 0.00000 NO3 0.00000 0.00000
Ba 0.00000 0.00000 F 0.00000 0.00000
NH4 0.00000 0.00000 SiO2 0.00000 0.00000
Fe(II) 0.00000 0.00000 B 0.00000 0.00000
Mn 0.00000 0.00000 PO4 0.00000 0.00000
Al 0.00000 0.00000 Br 0.00000 0.00000
  As(III) 0.00000 0.00000
  As(V) 0.00000 0.00000
  0.00000   0.00000
  0.00000   0.00000

 
Others Summary
Temperature 25.00 [°C] TDS 2384.91 [ppm]
pH 7.60 Conductivity 3625.42 [µS/cm]
CO2 9.31 [mg/l]
 

Note: The accuracy of the final water analysis depends mainly on the reliability of the feed water analysis.

Note: The hardness leakage depends on the NaCl quality (please refer to DIN 19604).
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 11/12

Designed system (Single line) Operating cost


System capacity 1500.0 [m3/d]
Regenerants [t] [USD]/[t]
Net capacity 697.6 [m3]
NaCl (100.00%) 0.00 5.00
Gross flow rate 62.5 [m3/h]
Total 0.00 [USD]
Net flow rate 58.1 [m3/h]

Resins [l] [USD]/[l] Water [m3] [USD/m3]


S 1567 10400.00 5.95 Supply and service 750.0 3.0
IN 42 1185.35 5.95 water
Total 68878.43 [USD] Waste water 0.0 0.0
Total 2250.00 [USD]
Net present value of expenses Product water cost [USD/m3]
Projected plant life 20.0 [a] Capital cost 98.731
Interest rate 4.0 [%] Operating cost 3.229
Annual operating cost 1,768,139 [USD/a] Total water cost 101.961
Operating cost escalation 4.0 [%/a]
Net present value 35,348,643 [USD]
LewaPlus
1 / 2021-08-15 / IX
2021-08-15 22:03:37 Softening and Dealkalization 12/12

Disclaimer

This LewaPlus software program is used for the dimensioning and calculation of Ion Exchange resin, Reverse Osmosis (hereafter RO) and Ultrafiltration
(hereafter UF) membrane systems applied in water treatment applications.

Within this program, Lanxess makes available to the system designer certain know-how concerning the design and operation of specific Lanxess
engineered ion exchange products (in unique system configurations such as fluidized bed, lift bed, multistep- and rinse bed technologies) as well as other
existing ion exchange technologies. In addition, Lanxess makes available to the system designer certain information about the design and operation of RO
and UF membrane systems, including scaling calculations, chemical and energy costs projections, and capital and operating cost projections based on the
pretreatment of the feed water, and design decisions made by the designer.

This know-how is given in good faith but without warranty, Our advice does not release you from the obligation to verify the information currently provided
- especially that contained in our safety data and technical information sheets - and to test our products as to their suitability for the intended processes
and uses. The application, use and processing of our products and the products manufactured by you on the basis of our technical advice are beyond our
control and, therefore, entirely your own responsibility.

Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery.