38999 -AMPHENOL JT MIL-DTL-38999 SERIES II

CREATE YOUR PAR T NUMBER

1 2 3A 4 3B 5 6 7
MS27474 T 24 F 35 P A -LC
SHELL STYLE CLASS SIZE PLATING LAYOUT CONTACT POLARIZATION MODIFIER
(OMIT FOR NORMAL)
(military part number example) *Note: Out of sequence

1 2 3 5 6 4* 7
JT07 RE- 24-35 P A -014 -LC
SHELL STYLE CLASS LAYOUT CONTACT POLARIZATION PLATING* MODIFIER
(OMIT FOR NORMAL)
(Commercial part number example)

STEP 1: S E L E C T S H E L L ST Y L E, P L U G OR RECEP TACL E


Mates with
RECEPTACLES PLUGS

+
MS27472 MS27497 JT01R MS27473 MS27484
(JT00R) (JTPQ00R) In-line with
Accessory
(JT06R) (JTG06R)
Front Mount with Rear Mount with Standard With Grounding Spring.
Threads.
Accessory Threads. Accessory Threads.

+
MS27500
MS27499E MS27513E MS27508E (JT08R)
(JT02R) (JT02RE) (JTP02RE)
Front Mount. No Front Mount. Rear Mount. No
Accessory Threads. No Accessory Threads. Accessory Threads. Available with PC pins. Contact us for details.

STEP 2: S EL ECT CL ASS

E° = Grommet & Compression Nut (not


applicable to box mount receptacles)
P° = Potting Ring & Cup
T° = No Rear Accessories
MS27474 RE* = Grommet & Compression Nut (not
(JTL07) applicable to box mount receptacles)
Rear Mount. Jam Nut RP* = Potting Ring & Cup
with Accessory Threads. RT* = No Rear Accessories
Contact Us for Details + Most Popular Military Only=(°) Commercial=(*)

204 For assistance in North America: +1 800.675.1214 • www.peigenesis.com • sales@peigenesis.com


38999 -AMPHENOL JT MIL-DTL-38999 SERIES II
STEP 3: S E L E CT L AY OUT (LISTED BY S I ZE ) STEP 4: S EL ECT P L AT ING
For listing by # of contacts,see pages 206-208.
Finish Military Commerical Commerical + SR
CONTACTS

LAYOUT
SERVICE TOTAL Cadmium-plated A - SR

NUMBER
RATING NUMBER
22D 22M 22 20 16 12
nickel base
8-35 M 6 6
8-44 M 4 4 Olive drab cadmium- B 014 386
8-98 I 3 3 plated nickel base
8-6 M 6 6

10-4P F I 4 4 Electroless nickel F 023 424
10-5 I 5 5
Electroless nickel - 453 467
10-13 M 13 13
space-compatible
10-35 M 13 13
10-98 I 6 6 Anodic coating C 005 300
10-99 I 7 7 (Alumilite)
12-3 II 3 3
12-4 I 4 4 Chromate-tested - 011 344
12-8 I 8 8 (Iridite 14-2)
12-22 M 22 22
Passivated steel E - -
12-35 M 22 22
12-98 I 10 10 (Hermetic only)

14-4 F I 4 4 Stainless steel - 155 -
14-5 II 5 5
14-15 I 15 14 1 Olive drab zinc - W52 -
14-18 I 18 18 cobalt
14-19 • I 19 19
SR = Strain Relief
14-35 M 37 37
14-37 M 37 37

14-68 F I 8 8
STEP 5: SEL ECT CONTACT

14-97 I 12 8 4
16-6 I 6 6
16-8 II 8 8

16-13 F I 13 13 Note: See Step 7 if not ordering contacts with part.
16-26 I 26 26 P = Pin A = Less Pin Contacts
16-35 M 55 55
S = Socket B = Less Socket Contact
16-42 M 42 42
16-55 M 55 55

STEP 6: SELECT POLARIZATION


16-99 I 23 21 2
18-11 II 11 11
18-28 I 28 26 2
18-30 I 30 29 1
18-32 I 32 32
N = Normal Standard (Omit for normal)
18-35 M 66 66
A = Highly-Popular
18-53 M 53 53 AB ANGLE OF ROTATION
18-66 M 66 66
B = Limited Availability
(DEGREES)

18-68 F I 18 18 C = Check for Availability
D = Check for Availability SHELL
18-96F I 9 9 NORMAL A B C D
20-1 M 79 79 SIZE
20-2 M 65 65 8 100 82 - - 118

20-11P F I 11 11
10 100 86 72 128 114
20-16 II 16 16
20-35 M 79 79 12 100 80 68 132 120
20-39 I 39 37 2 14 100 79 66 134 121
20-41 I 41 41 Mating Face 16 100 82 70 130 118
22-1 M 100 100 of Receptacle 18 100 82 70 130 118
22-2 M 85 85 20 100 82 70 130 118

22-14 F I 14 14 22 100 85 74 126 115
22-21 II 21 21 24 100 85 74 126 115
22-32 I 32 32
22-35 M 100 100

22-53P F I 53 53
22-55 I 55 55 STEP 7: SEL ECT M OD IFI ER
24-1 M 128 128
24-2 M 100 100
24-4 I 56 48 8

24-19 I 19 19 Note: LC is not marked on part
24-24 I 24 12 12
Omit for standard contacts
24-29 I 29 29
24-35 M 128 128
LC = Less contacts, wire hole fillers and plastic insertion/
24-37 I 37 37 extraction tool.

24-43P F I 43 23 20 (Purchase Order must state “Less Contacts”)
24-61 I 61 61

• NOT QPL’D F Not Tooled for RP or 02RE P = Pin Insert Only

For assistance in Europe and China, please see the back cover for a complete listing of our branch offices and contact numbers. 205
Specifications subject to change.
38999 -AMPHENOL JT MIL-DTL-38999 SERIES II
LAYOUT BY NUMBER OF CONTACTS

View of mating-face of pin insert

8 10 12 16 20 22 22D 22M
CONTACTS 3 4 5 6

Inactive.
Use 8-35
A D A
D B E A
C A C B
D B
C C
B

LAYOUT 8-98 12-3 8-44 10-4P•F 12-4 14-4•F 10-5 14-5 8-6 8-35
# OF CONTACTS 3-#20 3-#16 4-#22 4-#20 4-#16 4-#12 5-#20 5-#16 6-#22M 6-#22D
SERVICE RATING I II M I I I I II M M

CONTACTS 6 7 8 9

A A
E A
G G B
B
F G A B H
A A F
D F E G F B
E F B H H F C
B C
C D E C E E D
D C
C D D

LAYOUT 10-98 16-6 10-99 12-8 14-68•F 16-8 18-96F


# OF CONTACTS 6-#20 6-#12 7-#20 8-#20 8-#16 8-#16 9-#12
SERVICE RATING I I I I I II I

CONTACTS 10 11 12 13

Inactive.
Use 10-35
J A

H B K A
K
K J B
J A L
G C L B
A H C
L N M
H B H C 10 1
F D 9 11 2 G D
G C M D 3
K J G 8 13 12
F D E E 7 4 F E
E F 6 5

LAYOUT 12-98 18-11 20-11P•F 14-97• 10-13 10-35 16-13•F


# OF CONTACTS 10-#20 11-#16 11-#12 8-#20, 4-#16 13-#22M 13-#22D 13-#16
SERVICE RATING I II I I M M M

CONTACTS 14 15 16 18

A
L B
M
K T N C
L A L A U
K M B K M N B
R N C J S P D
J T U P
J C
H P D S R
H H E
G E D
F G R
F E G F

LAYOUT 22-14•F 14-15 20-16 14-18 18-68•F


# OF CONTACTS 14-#12 14-#20, 1-#16 16-#16 18-#20 18-#16
SERVICE RATING I I II I I

• NOT QPL’D FNot Tooled for RP or 02RE P = Pin Insert Only Contact us for more information.

206 For assistance in North America: +1 800.675.1214 • www.peigenesis.com • sales@peigenesis.com


38999 -AMPHENOL JT MIL-DTL-38999 SERIES II
LAYOUT BY NUMBER OF CONTACTS

View of mating-face of pin insert

8 10 12 16 20 22 22D 22M

CONTACTS 19 21 22
Inactive.
Use 12-35

1 1

20 21
22 22

LAYOUT 14-19• 24-19• 22-21 12-22 12-35


# OF CONTACTS 19-#20 19-#12 21-#16 22-#22M 22-#22D
SERVICE RATING I I II M M

CONTACTS 23 24 26 28

R A A
B R B
P S T Pa S T C
Y UC U
b
N Z D N D
Z V
X V c
M W M E
E Y W
L X
L
K G
F K G F
J H J H

LAYOUT 16-99 24-24 16-26 18-28


# OF CONTACTS 21-#22, 2-#16 12-#16, 12#12 26-#20 26-#20, 2-#16
SERVICE RATING I I I I

CONTACTS 29 30 32

T A
S U B
S A R e V C
R B
d T f
P U C P d j W D
c e
N b V D g
N c X E
g b h
f W E
M a
Z M Y F
X F a Z
L Y J
K J G L G
H K H

LAYOUT 24-29 18-30 18-32 22-32


# OF CONTACTS 29-#16 29-#20, 1-#16 32-#20 32-#20
SERVICE RATING I I I I

CONTACTS 37 39 41

Inactive.
Use 14-35

1 1

31 31 21
21

11

LAYOUT 14-35 14-37 24-37 20-39 20-41


# OF CONTACTS 37-#22D 37-#22M 37-#16 37-#20, 2-#16 41-#20
SERVICE RATING M M I I I

• NOT QPL’D FNot Tooled for RP or 02RE P = Pin Insert Only Contact us for more information.

For assistance in Europe and China, please see the back cover for a complete listing of our branch offices and contact numbers. 207
Specifications subject to change.
38999 -AMPHENOL JT MIL-DTL-38999 SERIES II
LAYOUT BY NUMBER OF CONTACTS

View of mating-face of pin insert

8 10 12 16 20 22 22D 22M
CONTACTS 42 43 53 55

Inactive.
S A
Use 16-35
R T B S A
n U R T B
V C
P m p n U
k W q
P m p V C
N AA BB D 1 k q W
z N AA BB D
1 r 21
z r 17 32
M h GG CC X E GG CC X E 10 40
21 y s M h y 4 25
HH 41 HH s 47
L g FF DD Y F L g FF DD Y F 1 53
41 x EE t 51 x EE t
31 42
f w u 53 52 f w u
v a Z v a Z
K e d
K e d b 55
b 3
c G 52
J c G 31 J 9
H 11 H 16 31 46
24 39
11

LAYOUT 16-42 24-43P•F 18-53 22-53P•F 16-35 16-55


# OF CONTACTS 42-#22 23-#20, 20-#16 53-#22 53-#20 55-#22D 55-#22M
SERVICE RATING M I M I M M

CONTACTS 55 56 61 65

A B
Z Z A
a C B
Y w Y a b
A v b v
U V B c D u C
T GG X c
W C X u x
n d E t GG HH w d D 1
S m X FF y W
Y p W t HH FF x
AA q D e F V
s NN JJ e E
k s EE LL JJ PP 21
R z GG BB r Z V z f
r
EE MM KK y
F
j y HH CC U f
E KK LL
41
FF r DD AA z
P s a U g G q DD g G
i EE DD F T 65
x t b q CC BB BB AA h H
h p CC 31
N h w u T H 61
v c p k S n i J
g G n R m k j
f d S m J 51
e N P M L K
M H R K N
L J P L 11
K M

LAYOUT 22-55 24-4 24-61 20-2


# OF CONTACTS 55-#20 48-#20, 8-#16 61-#20 65-#22
SERVICE RATING I I I M

CONTACTS 66 79 85
Inactive. Inactive. Use 20-35
Use 18-35 12
20
29
39
48
58
67
1 1
25 34 25 34 5
17 43 75
17 43
10 51 10 51 1 82
4 58 31 31
4 58 51 51

1 64 1 64

2 2 21 79 21 79

71 4 85
3 66 3 66 71
61 61 11 81
63
9 9 63
19 74
57 41 41 47
16 16 57 11 11
24 50 24 50 28 66
33 42 33 42 38 57

LAYOUT 18-35 18-66 20-1 20-35 22-2


# OF CONTACTS 66-#22D 66-#22M 79-#22M 79-#22D 85-#22
SERVICE RATING M M M M M

CONTACTS 100 128

Inactive. Inactive. Inactive.


Use 22-35 No Replacement Use 24-35
59
40 51 48 71
19 73 36 82
25 94
25 46 67 8 15 105 115
35 56 25 46 67
16 77 16 35 56 77 1
8 86 8 3 92
86
1 94 1 94
2
95 2 1
3 96
95 99
125
3 96 4
4 97 4 97
5 98 5 98 2 100
6 99 6 99
100 100 7
7 7 128
14 121
15 93 24
24
15 93 114
34 55
85 24 45 66 85 35 58 70 81 104
45 66
76 34 55 76 47 93

LAYOUT 22-1 22-35 24-2 24-1 24-35


# OF CONTACTS 100-#22M 100-#22D 100-#22 128-#22M 128-#22D
SERVICE RATING M M M M M

• NOT QPL’D FNot Tooled for RP or 02RE P = Pin Insert Only Contact us for more information.

208 For assistance in North America: +1 800.675.1214 • www.peigenesis.com • sales@peigenesis.com