Smart IV Curve
Huawei Confidential
Smart IV Curve
Severe blockage causes hotspot risks on panels and affects panels reliability within the life
Dust 3-30% for every string High
cycle
Glass breakage 5% for every string Energy yield loss, panels reliability risks, and personal safety O&M risk Very High
Shade 1-5% for every string Same with the dust Very High
Mismatch in the PV string 1-4% for every string Maybe there is dust, shade or other problems Very High
String connection reverse 0.5-0.7% for every string The risk of electric shock is in O&M Very Low
PV module degradation 3-7% for the whole plant Panel reliability is affected within the life cycle Inevitable
Diode short circuit 1-4% for every string Panel reliability is affected within the life cycle High
PV module invalid 0.5-0.7% for every string The string information may not be configured successfully in system Very Low
Abnormal orientation 0.5-0.7% for every string Inherent problems in PV plant design and cause energy yield loss Very Low
In severe cases, panels are burnt, causing insulation deterioration, accelerating aging, and
Hot spot 0.01% for every panel hotspot Very High
prolonging the service life of panels
High cable resistance 0.5-5% for the whole plant There is a fire risk caused by DC arcing. Low
Hidden crack Uncertain The panel causes hot spot risks, and reliability is affected within the life cycle. Very High
Huawei Confidential
Smart IV Curve
Rooftop
Disconnect the string for test Rooftop
• Low Sampling Rate • Dispersed
• High Risk for Both • high altitude risk
Utility
Analyze the curves one/one Utility
• Low Efficient • Large scale and wide area
• Uncertainty • Workload is heavy
Huawei Confidential
Smart IV Curve
Solar Cell
PV string:
series/parallel connection of Cell
Equivalent Model
Huawei Confidential
Smart IV Curve
Huawei Confidential
Smart IV Curve
Smart I-V Curve Diagnosis
5 GW+ Application Worldwide for Elevated O&M Efficiency
Accurate Failure Diagnosis &
14.5 MW Failure Rate 0.74% 40 MW Failure Rate 1.42%
Recovery Suggestions Provided Portfolios of PMGD projects in Chile Ground-mounted PV Plant in Golmud
9,61% 2,53%
8,26% 1,85%
0,84%
21,25% 0,51% Top 4
0,34% PV Module Failure
Huawei Confidential
Smart IV Curve
Huawei Confidential
Smart IV Curve
Current/Voltage sensors for Stings 1. Collects IV curve data with high accuracy
2. Distribute Instruction
SACU/SmartLogger …
5. Collect String Data
3. Execute Instruction
Inverter
MBUS
Huawei Confidential
Smart IV Curve
Smart I-V Curve Diagnosis can analyze 14+ faults
Simple:
One Click Smart I-V Curve Diagnosis
Efficient:
100 MW plant, 2,000,000 +data, 15 minutes' diagnosis(based on185KTL)
14+ Faults Diagnosis Automatic:
Diagnosis and O&M Report automatic generation
Note: The system can automatically calculate the radiation intensity without EMI. Valuable:
And the Smart I-V diagnosis can be started when the irradiance>400W/M2. Improved yields, Lower OPEX, Guarantee plant safety
No Fault Sort the possible causes of failure No Fault Sort the possible causes of failure
3 Abnormal PV module output current Shade/glass breakage/hidden crack 10 Slight current mismatch in the PV string Dust/slight shade/glass breakage
6 Low PV string power Abnormal orientation/dust/PV module degradation 13 Abnormal curve near MPP in the PV string Hotspot/hidden crack/glass breakage
Huawei Confidential
Smart IV Curve
TUV Qualified Smart I-V Curve Diagnosis Solution
0.5% Sensor Accuracy Panel Failure Test Passed
Huawei Confidential
Smart IV Curve
Smart I-V Curve for fast fault recovery and easy O&M
VS
Items Automatic Manual 1 2 Huawei Advantage
3 4
Scan Consistency More than 200 strings at the same time String by string at different time More Convenient: Online
Analysis & Report Automatic Analysis and Report Analysis by Technician More Intelligent: Automatic
Huawei Confidential
Smart IV Curve
Smart I-V Curve Diagnosis- Key Performance
Device Model Version
SUN2000-36KTL
V200R002C00SPC113 and Later
SUN2000-42KTL
SUN2000-60KTL-M0 All versions
Huawei Commercial and utility Smart
SUN2000-60KTL-HV-D1-001 V100R001C00SPC101 and later
Inverter
SUN2000-100KTL-H1
SUN2000-105KTL-H1 All versions
SUN2000-185KTL-H1
Smartlogger Smartlogger 2000 V200R002C10SPC101 and later
NetEco NetEco 1000S V100R003C00SPC110 and later
FusionSolar FusionSolar 6.0 Smart PV730 V300R006C00SPC220 and later
Key performance
The sunlight exposure intensity must be at least (600W/m²)
String configuration information must be correct
A maximum of 200 inverters can be diagnosed at a time
Huawei inverter I-V scanning duration < 1s ;
You are advised to run diagnosis between 11:00 am and 13:00 pm.
Huawei inverter I-V scanning resolution: 128 data points
function after PV modules are cleaned or heavy rain has stopped.
The PV modules in the same array have an identical type and model. Every PV string has the same number of PV modules connected in series.
Huawei Confidential
Smart IV Curve
Smart I-V Curve report introduction
Huawei Confidential
Smart IV Curve
Smart I-V Curve Detection Report overview introduction
Huawei Confidential
Smart IV Curve
How to use Smart IV Curve (click on the image to launch the video)
Huawei Confidential
Smart IV Curve
Smart I-V Curve : Case study
Huawei Confidential
Smart IV Curve
Smart I-V Curve : Case study
Huawei Confidential
Questions ?