You are on page 1of 1

8 7 6 5 4 3 2 1

2 286 3-F 1. CHANGED DISPLAY AND REMOVED CONN & SEAL. 25FEB15 T. VAN WERT
3 341 4-C 1. CHANGED CABLE 5 MAT'L, WAS 3x14AWG. 10JUL15 T. VAN WERT
P/L 2. ADDED CUSTOMER SUPPLIED FUSES ON CBL 5.
4 468 2-A 4-C 1. ADDED MODEL 20HD & REVERTED CBL 5 MAT'L. 20OCT16 B.DOUTRICH
F 465 P/L 2. REMOVED ITEM 14, CUSTOMER SUPPLIED FUSES. F
P/L 3. CHANGED ITEM 11, WAS 4 AWG.
5 P/L 1. CHANGED P/N OF ITEM 2, WAS 30268. 17OCT17 R. KEOWN

USB

USB
P/L
P/L
2. CHANGED P/N OF ITEM 6, WAS 20223.
3. CHANGED P/N OF ITEM 13, WAS 90250.
DISPLAY 2 DISPLAY 2
P/L 4. ADDED ITEM 14.

CAN1

CAN2

CAN1

CAN2
AUX

AUX
6 830 P/L 1. CHANGED ITEM 8 P/N TO 20394, WAS 30179. 08JUL20 W. GARZON
P/L 2. CHANGED ITEM 9 P/N TO 20395, WAS 30239.

GYRO DC 6 3
CABLE 4
DISCONNECT SWITCH CABLE 7
E
2x22AWG & 2x24AWG, SHIELDED,
USB EXTENDER, 6 14 E
0.5 METER LENGTH
DC DIST (CAN, PLASTIC)
2 METER LENGTH
PANEL (USB, PLASTIC)

CUSTOMER 14
2 10
24 VDC, 10 A
SUPPLIED CABLE 1 3
CIRCUIT 2x12AWG CABLE 3
2x22AWG & 2x24AWG,
4 5 4
BREAKER 5 METER LENGTH
SHIELDED, 25 METER LENGTH
(CAN, PLASTIC)
GYRO AC OPTIONAL SECOND
D DISCONNECT SWITCH SEAKEEPER DISPLAY KIT D
AC DIST 26 OR 20HD 13 4
PANEL GYRO SEAWATER
CUSTOMER 1 8 9 1 PUMP, 230 VAC
208 - 230 VAC, SUPPLIED CABLE 2 1 CABLE 5
3x14AWG or 3x2.5mm2
(CUSTOMER
20 A, 1Ø, 50/60 Hz CIRCUIT 3x10AWG or 3x6.0mm2
BREAKER 3 METER LENGTH 3 METER LENGTH SUPPLIED)
12

C C
11 5
CABLE 6
10AWG or 6.0 mm2 14 30300 ADAPTER CABLE, M12-12 TO USB-A 1 SEAKEEPER
GROUND WIRE 13 90467 OPTIONAL SECOND DISPLAY KIT 1 SEAKEEPER
(CUSTOMER SUPPLIED) 12 SEAWATER PUMP, 230VAC, 5 AMPS MAX. 1 SHIPYARD
11 WIRE, 10 AWG (6.0 mm2) A/R SHIPYARD
10 20248 CABLE, MARINE, DC, 2 X 12AWG, 5m 1 SEAKEEPER
9 20395 CABLE ASSY, MARINE, 3 x 14AWG, 3m 1 SEAKEEPER
8 20394 CABLE ASSY, MARINE, 3 x 10AWG, 3m 1 SEAKEEPER
7 30246 WATERPROOF CAP, CAN, MALE 1 SEAKEEPER
B NOTES: 6 30301 CABLE, CAN, FEMALE-MALE, 0.6m 1 SEAKEEPER B
5 30249 TERMINATOR, CAN, 120 OHM, FEMALE 1 SEAKEEPER
1 CABLES PROVIDED TO CONNECT THE AC 3 2nd CABLE FROM REAR OF DISPLAY IS
4 30244 TEE ADAPTER, CAN, 3-WAY, F-M-F 1 SEAKEEPER
INPUT POWER (ITEM 8) AND SEAWATER PUMP ISOLATED FOR SHIP MONITOR CANbus.
3 30243 CABLE, CAN, FEMALE-MALE, 25m 1 SEAKEEPER
OUTPUT POWER (ITEM 9) ARE SUPPLIED AS 2 30298 DISPLAY, TOUCHSCREEN, IP67 1 SEAKEEPER
LENGTH 3m. THE LOCATIONS CHOSEN FOR 4 WHEN 2nd DISPLAY IS INSTALLED, CONNECT 90416 SEAKEEPER 20HD GYRO ASSEMBLY
POWER DISTRIBUTION SHOULD TAKE THIS 2nd CAN CABLE TO 1st TEE AND MOVE 1 1 SEAKEEPER
90244 SEAKEEPER 26 GYRO ASSEMBLY
INTO CONSIDERATION. TERMINATOR TO END OF 2nd TEE. SEAKEEPER
ITEM DESCRIPTION QTY SUPPLY
PART NO.
2
2 CABLE PROVIDED TO CONNECT THE DC INPUT 5 CONNECT 10 AWG (6mm ) PE CONDUCTOR TO PROPRIETARY AND CONFIDENTIAL

POWER (ITEM 10) IS SUPPLIED AS LENGTH 5m. VESSEL GROUNDING BUS TO COMPLY WITH THE INFORMATION CONTAINED IN THIS

A DRAWING IS THE SOLE PROPERTY OF


SEAKEEPER, INC. ANY REPRODUCTION A
THE LOCATION CHOSEN FOR POWER EN/IEC 60204-1 CLAUSE 6.3.3 AND ABYC E-11.5.4. IN PART OR AS A WHOLE WITHOUT THE
45310 ABELL HOUSE LANE, SUITE 350, CALIFORNIA, MD 20619
WRITTEN PERMISSION OF SEAKEEPER,
SEAKEEPER 26 / 20HD GYRO
DISTRIBUTION SHOULD TAKE THIS INTO N/A
INC. IS PROHIBITED.
CABLE BLOCK
CONSIDERATION. S. GOSS 05 AUG 2014 DIAGRAM
B.DOUTRICH 05 AUG 2014

R. KEOWN 05 AUG 2014


90310 6 1 0F 1

8 7 6 5 4 3 2 1