DIGITAL LOAD MONITORING RELAY
Usiog modem technology and microprocessor system, toad monitoring
‘ela is designed and manufactured for accurate conto of dsordering
‘caused by curentasymmety and under curentin al industa centers
withno CTusagein:womodals(1-60A),(0.51.5A)
WEIGHT 18097
(62487905)
P30
‘Shiva Amval LOAD monitoring relay features
1 Sphaae deviees protection using microprocessor aystem
= Current coil based on curve
" Current measuring without CT using and by passing maximum 25m
Wite arety trom the hole
"Displaying cuent. set values and error messages
"Proloeion against, under curent and current asymmetry
18 naieator tor ndeatng:
‘OL: overload (1 = 604),(0 8-154). %
UL underiad (asustabe 1A ess than OL)
“A eunentasymmetry\? ~ 100%)
‘ON: on dela of rset delay (0 240 Sec)
OFF: of doy for OL ad At fats (0 10 See)
OFF (uo detay for UL fault (5 ~ 10 See)
‘Normal: relay contion *
Delay Start: prmary star time (0-120 Sac}
‘Aindeators are ON during setting and ashing during faut
‘occurrence
6 in case of sling zor0 for UL, undorcuronis aisle
12: pemnary start tna isthe time ater relay connection and passing
‘current. Overcurrent for motor prmary drive) snot considered.)
Technical specification:
«= supply voltage:180- 250 VAC / 50-60 Hz
DLFISA0.14,
4650
"operating conn
umicty- 70%
1 Output 4 rolay
Device operation
Tables f= 2-4) are used for device adjustment. Error messages
are acconing*0 table)
Buttons and display operation in normal mode (lay eon table)
baton Description/aieplay
a Device seltng (able 2)
ere _| Reset
Tor 2 ceconds 4 | ROY cordon soting
Displaying the carent
Device setting table @
Seting range
Entering | Flashing
seting stage | indicator [PP®S"P°ON'=PY| py putonss
a OL | Maxcurent [o.s:5a/ 1-608)
< ut | Min current
= %A _esrentasymmety] —7-100%
a ON | ondety | 0.240806
“ OFF [ordetay%A, OL] 0-10 sec
By OFF(u) | ondeiayut | 51080
+ Delay Star|Primary stat ime] 9-120 80
zi ‘Save all applied changes
@
Error messagi table @)
Flashing ndiator| Detail | Display | Relay off delay
ou Overeurent_ | Lod Pe
ut Under curent | UC | OFF(u) set time
6A [Curent asymmetry] UC | OFF settime
Reset «9 +4
‘Alter faut fixing and elapsing on delay.normal display is lashing
and displaying error.
Soting relay condition tabie@
Eronig seth ray san slag by rosario"? socond
eve aanay ;
assay Detail
ce Ro on ding at onion
770 | Rosy isan dvng roma anton
@.
Autorecoser
‘The dovcos putin auto rectoser mode by connecting auto terminalto
phase
In this case ater each fault which leads to relay disconnection, the
evice which automaticaly cisplays countdown mode with delay te
‘of Ondelay #80 Sec, connects and keepsitsdutyinnormalstuation
In case offal repeton, this operation psa for 3 times and attr
‘hatthe devices waiting for manval Reset
‘Auto recloser is done by pressing 4 and gbuttonsimeltanously.
the eisconnectn time value Is calculated’as below:
T(off}-OFF DELAY
(oM=O8F DELAYNote: In Auto recloser term, the possibilty of anual resets avalable
aswel.
Installation and utilization guide
Fs install digital monitoring relay onthe ral. In case of absence of ai,
Use the ral nside the box. Wiring the dovice in accordance wih wiring
‘iagram and pass the current care wire through |, Land (passing
current channels) curent holes
"Note: In this model the load that pass from the noe 12), hole is
ftectoss.
@
eeecee
ithe erent at workings 10A and sang cents 30, last
for ec, the aajsted vies are as below.
ob tea
ULEA 0-8 Aaccording tothe usage
a0
DELAY START 6See
ON DELAY: 5 See
OFF DELAY. 5 See
Note that these values change based on motor condition and
sensivty
@
[Note : Two below factors are noticeable in UBC error
(current asymmetry)
4+ low adjusted vale for %A error raises sensitivity
Itis necessary to set the parameters on 40%
2-passing current channel via phase R or T after load monitoring
‘lay e.g. tum on the fan
Itmay fix after wiring modification
5 yearn question asked gurais une thse conan
|.atmostt shouldbe within 3 yeas rom the dat pita on th bil of he rout
2: abel on te prot shold be ste and sun
®
‘Shive Amal products in azcordance with inomatonal standards
me Ce
| ww shivaamva.com
‘customer suppor: (+98)3135723500-%
sale: (-98)3195720444-5 fn: (e98)31926729400
Emi info@ehivaarvaj com
‘Shiva Amal Company is also presenting servic in eybarspace
‘Shia Arwvaj number 0098 913 403 43 51