Professional Documents
Culture Documents
Vickers
Vane Pumps
Vickers offers the most complete line of Twelve vane system provides low
hydraulic intravane pumps for industrial amplitude flow pulsations resulting in
applications. A wide variety of single low system noise characteristics.
and multiple configurations enables you
to select the precise pump or Hydraulic balancing, designed to
combination best suited for your prevent internally-induced radial shaft
application. and bearing loads, provides long life.
Compact size and ease of service allow Factory tested cartridge kits provide
maximum equipment design flexibility. new pump performance upon
Pumps are available in single, double installation.
and thru-drive configurations.
The cartridge kit design offers fast and
Features and Benefits efficient field serviceability. The
High operating pressure capabilities in cartridge is independent of the drive
compact packages provide high power shaft, allowing for easy change of flow
to weight ratios and lower installed capacity and servicing without
costs. removing the pump from its mounting.
Low noise characteristics inherent in Inlet and outlet ports can be oriented
intravane design enhance operator in four different positions relative to
comfort. each other, providing greater
installation flexibility and ease of
machine design.
2
Table of Contents
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 7
Operating Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 - 18
Installation Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 - 28
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 - 30
3
Performance Data Single, Double & Thru-Drive Vane Pumps
25V 10, 12, 14, 17, 21 172 (2500) 69 (1000) 159 (2300)
25VT 12, 14, 17, 21 172 (2500) 69 (1000) 159 (2300)
25**V 12, 14, 17, 21 172 (2500) 69 (1000) 159 (2300)
**25V 12, 14, 17, 21 172 (2500) 69 (1000) 159 (2300)
* A transient (peak) pressure 10% over the continuous pressure rating for 0.5 seconds or less duration is allowed.
Speed limits
Minimum speed, all models and fluid combinations . . . . . . . . . 600 rpm
Maximum speed - standard models using antiĆwear fluid . . . 1800 rpm
Standard models using synthetic and waterĆinĆoil emulsions . 1200 rpm*
Models using water glycol fluid . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500 rpm*
* See Vickers brochure #579.
4
Single Pump Model Code
Model Code
1 2 3 4 5 6 7 8 9 10 11 12
10 Design
5 Port Connections
A - SAE 4-bolt flange 11 Rotation
(Viewed form shaft end of pump)
6 Port Connection Modifier L - Left hand for counterclockwise
R - Right hand for clockwise
Omit - Inch thread port connection
(4-bolt flange)
M- Metric port connection 12 Special Suffix
(4-bolt flange - N/A on 20V)
167 - 2-bolt, 5.00” dia. pilot
(25V only - N/A for VS or VM
models)
Note: For options other than listed in the model code, i.e. shafts, ports, displacements
and mountings, contact your Vickers representative.
5
Double Pump Model Code
Model Code
1 2 3 4 5 6 7 8 9 10 11 12 13
Omit if not required A - SAE 4-bolt flange (Viewed from cover end of pump)
All series except 2525V & 4535V
6 With No.1 outlet opposite inlet:
2 Series Designation Port Connection Modifier AA - No. 2 outlet 135 CCW from inlet
Displacements cm3/r (in3/r) Omit - Inch thread port connection AB - No. 2 outlet 45 CCW from inlet
(4-bolt flange) AC - No. 2 outlet 45 CW from inlet
Model Shaft End Cover End
AD - No. 2 outlet 135 CW from inlet
2520V - 33 - 67 7 - 45 M- Metric port connection
With No.1 outlet 90 CCW from inlet:
(2.0 - 4.1) (0.45 - 2.8) (4-bolt flange) BA - No. 2 outlet 135 CCW from inlet
2525V - 33 - 67 33 - 67 BB - No. 2 outlet 45 CCW from inlet
(2.0 - 4.1) (2.0 - 4.1) 7 Geometric Displacement - BC - No. 2 outlet 45 CW from inlet
3520V - 81 - 121 7 - 45 BD - No. 2 outlet 135 CW from inlet
Cover End Pump
(4.9 - 7.4) (0.45 - 2.2) With No.1 outlet inline with inlet:
3525V - 81 - 121 33 - 67 Rated capacity (USgpm) at 1200 rpm, CA - No. 2 outlet 135 CCW from inlet
(4.9 - 7.4) (2.0 - 4.1) 6,9 bar (100 psi) CB - No. 2 outlet 45 CCW from inlet
4520V - 138 - 193 7 - 45 CC - No. 2 outlet 45 CW from inlet
Frame Code cm3/r in3/r CD - No. 2 outlet 135 CW from inlet
(8.4 - 11.8) (0.45 - 2.2) Size (USgpm) With No.1 outlet 90 CW from inlet:
4525V - 138 - 193 33 - 67 **20V 2 7 0.43 DA - No. 2 outlet 135 CCW from inlet
(8.4 - 11.8) (2.0 - 4.1) 5 18 1.1 DB - No. 2 outlet 45 CCW from inlet
4535V - 138 - 193 81 - 121 8 27 1.7 DC - No. 2 outlet 45 CW from inlet
(8.4 - 11.8) (4.9 - 7.4) 9 30 1.9 DD - No. 2 outlet 135 CW from inlet
11 36 2.2
3 Pilot Designation 12 40 2.5 Series 2525V & 4535V
14 45 2.8 With No.1 outlet opposite inlet:
Omit - Standard pilot **25V 10 33 2.0 AA - No. 2 outlet opposite inlet
S - SAE per ISO 3019/1 (SAE J744) 12 40 2.5 AB - No. 2 outlet 90 CCW from inlet
14 45 2.8 AC - No. 2 outlet inline with inlet
(N/A on 2525V) 17 55 3.4 AD - No. 2 outlet 90 CW from inlet
M - Metric per ISO 3019/2 100A2HW 21 67 4.1 With No.1 outlet 90 CW from inlet:
(N/A on 2525V) 4535V 25 81 4.9 BA - No. 2 outlet opposite inlet
30 97 5.9 BB - No. 2 outlet 90 CCW from inlet
4 Geometric Displacement - 35 112 6.8 BC - No. 2 outlet inline with inlet
38 121 7.4 BD - No. 2 outlet 90 CW from inlet
Shaft End Pump
With No.1 outlet inline with inlet:
Rated capacity (USgpm) at 1200 rpm, 8 Mounting CA - No. 2 outlet opposite inlet
6,9 bar (100 psi) CB - No. 2 outlet 90 CCW from inlet
Omit - Flange mounting CC - No. 2 outlet inline inlet
Frame Code cm3/r in3/r F - Foot mounting CD - No. 2 outlet 90 CW from inlet
Size (USgpm) With No.1 outlet 90 CW from inlet:
DA - No. 2 outlet opposite inlet
25**V 10 33 2.0 9 Shaft
DB - No. 2 outlet 90 CCW from inlet
12 40 2.5 Std. Pilot Shafts DC - No. 2 outlet inline with inlet
14 45 2.8 DD - No. 2 outlet 90 CW from inlet
Str. HD Str.
17 55 3.4 Key Key
Model Spline
21 67 4.1 11 Design
35**V 25 81 4.9 25**V - 45**V 1 86 11
30 97 5.9
35 112 6.8 “S” SAE Pilot & “M” Metric 12 Rotation
38 121 7.4 ISO Pilot Shafts
Str. HD Str. Metric Str.
(Viewed form shaft end of pump)
45**V 42 138 8.4
45 147 9.0 Model Key Key Key Spline L - Left hand for counterclockwise
50 162 9.9 R - Right hand for clockwise
25**VS - 45**VS 202 203 N/A 297
60 193 11.8 25**VM - 45**VM N/A N/A 292N N/A
13 Special Suffix
Note: For options other than listed in the model code, i.e. shafts, ports, 167 - 2-bolt, 5” dia. pilot
displacements and mountings, contact your Vickers representative. (25**V only - N/A for VS or VM models)
6
Thru-Drive Pump Model Code
Model Code
1 2 3 4 5 6 7 8 9 10 11 12 13
Note: For options other than listed in the model code, i.e. shafts, ports, displacements
and mountings, contact your Vickers representative.
7
Operating Data
8
Application Data
9
20V Performance Characteristics
70 (18.49) 7 (100)
70 (1000) 12
160 (2300)
60 (15.85)
DELIVERY - l/min (US gpm)
50 (13.21)
40 (10.58)
7 (100)
70 (1000)
30 (7.93) 140 (2000) 5
210 (3000)
20 (5.28)
10 (2.64)
0
400 800 1200 1600 2000
SPEED - RPM
16 (21.46)
INPUT - kw (hp)
70 (1000) 12
8 (10.73) 140 (2000) 5
4 (5.36) 70 (1000) 5
7 (100) 12
0 7 (100) 5
400 800 1200 1600 2000
SPEED - RPM
10
20V Performance Characteristics
7 (100)
53 (14.0)
70 (1000)
9
160 (2300)
207 (3000)
45 (12.0)
DELIVERY - l/min (US gpm)
38 (10.0)
30,3 (8.00)
23 (6.00)
15 (4.00)
7 (100)
70 (1000) 2
140 (2000)
7,57 (2.00)
0
400 800 1200 1600 2000
SPEED - RPM
26,1 (35)
15 (20)
140 (2000) 9
11,2 (15)
3,73 (5)
7 (100) 9
0
7,5 (10)
140 (2000) 2
3,73 (5)
70 (1000) 2
0 7 (100) 2
400 800 1200 1600 2000
SPEED - RPM
11
20V Performance Characteristics
80 (21.13) 7 (100) 14
70 (1000) 14
140 (2000) 14
70 (18.49)
7 (100) 11
70 (1000) 11
60 (15.85) 140 (2000) 11
DELIVERY - l/min (US gpm)
210 (3000) 11
50 (13.21)
7 (100) 8
70 (1000) 8
140 (2000) 8
210 (3000) 8
40 (10.58)
30 (7.93)
20 (5.28)
10 (2.64)
0
400 800 1200 1600 2000
SPEED - RPM
210 (3000) 11
24 (32.18)
140 (2000) 14
20 (26.82)
210 (3000) 8
INPUT - kw (hp)
140 (2000) 11
16 (21.46)
140 (2000) 8
12 (16.09)
70 (1000) 14
70 (1000) 11
8 (10.73)
70 (1000) 8
4 (5.36)
7 (100) 14
7 (100) 11
0 7 (100) 8
400 800 1200 1600 2000
SPEED - RPM
12
25V(T), 25**V, & **25V Performance Characteristics
76
bar (psi) 100
bar (psi) Code
(20.0) (26.42) 7 (100)
70 (1000)
17
140 (2000)
DELIVERY - l/min (US gpm)
30 40
(8.00) (10.58)
15 20
(4.00) (5.28)
0 0
400 800 1200 1600 2000 400 800 1200 1600 2000
INPUT - kw (hp)
7,5 70 (1000) 5
(10.0) (6.71)
7 (100) 17
7 (100)
7 (100) 12
0 0
400 800 1200 1600 2000 400 800 1200 1600 2000
13
25V(T), 25**V, & **25V Performance Characteristics
100 (26.42)
DELIVERY - l/min (US gpm)
80 (21.13) 7 (100)
70 (1000)
140 (2000) 14
170 (2500)
60 (15.85)
40 (10.58)
20 (5.28)
0
400 800 1200 1600 2000
SPEED - RPM
70 (1000) 21
15 (20.12)
70 (1000) 14
10 (13.41)
5 (6.71)
7 (100) 21
7 (100) 14
0
400 800 1200 1600 2000
SPEED - RPM
14
35V(T), 35**V, & **35V Performance Characteristics
160 (42.27)
70 (1000)
140 (2000) 25
170 (2500)
120 (31.70)
100 (26.42)
80 (21.13)
60 (15.85)
40 (10.58)
20 (5.28)
400 800 1200 1600 2000
SPEED - RPM
Codes 25 and 35 Input bar (psi) Code
65 (87.17)
55 (73.76)
40 (53.64)
140 (2000) 25
35 (46.94)
30 (40.23)
25 (33.53) 70 (1000) 35
20 (26.82)
70 (1000) 25
15 (20.12)
10 (13.41)
5 (6.71) 7 (100) 35
7 (100) 25
0
400 800 1200 1600 2000
SPEED - RPM
15
35V(T), 35**V, & **35V Performance Characteristics
7 (100)
70 (1000) 38
140 (2000)
200 (52.84) 170 (2500)
180 (47.55)
7 (100)
70 (1000)
DELIVERY - l/min (US gpm)
140 (36.99)
120 (31.70)
100 (26.42)
80 (21.13)
60 (15.85)
40 (10.58)
400 800 1200 1600 2000
SPEED - RPM
Codes 30 and 38 Input
bar (psi) Code
70 (93.87)
60 (80.46)
45 (60.35)
INPUT - kw (hp)
140 (2000) 30
40 (53.64)
35 (46.94)
30 (40.23) 70 (1000) 38
25 (33.53)
70 (1000) 30
20 (26.82)
15 (20.12)
10 (13.41) 7 (100) 38
7 (100) 30
5 (6.71)
0
400 800 1200 1600 2000
SPEED - RPM
16
45V(T), 45**V Performance Characteristics
160 114
(42.27) (30.0)
120 76
(31.70) (20.0)
80 38
(21.13) (10.0)
40 0
(10.58) 400 800 1200 1600 2000 400 800 1200 1600 2000
INPUT - kw (hp)
70 52,2
(93.87) (70.0)
60 45
(80.46 140 (2000) 42 (60.0)
50) 37,3
(67.05) (50.0)
40 70 (1000) 60 30 70 (1000)
(53.64) (40.0)
30 70 (1000) 42 22,4
(40.23) (30.0)
20 15
(26.82) (20.0)
10 7,5
7 (100) 60
(13.41) 7 (100) 42 (10.0)
7 (100)
0 0
400 800 1200 1600 2000 400 800 1200 1600 2000
17
45V(T), 45**V Performance Characteristics
Code 50 Displacement
bar (psi) Code
360 (95.10)
320 (84.54)
140 (2000) 50
170 (2500)
240 (63.40)
200 (52.84)
160 (42.27)
120 (31.70)
80 (21.13)
40 (10.58)
400 800 1200 1600 2000
SPEED - RPM
Code 50 Input
bar (psi) Code
110 (147.51)
100 (134.10)
80 (107.28)
INPUT - kw (hp)
60 (80.46)
50 (67.05)
40 (53.64)
70 (1000) 50
30 (40.23)
20 (26.82)
10 (13.41)
7 (100) 50
0
400 800 1200 1600 2000
SPEED - RPM
18
20V Installation Dimensions
22,2
(.875) 35,7 2,36
(1.41) (.093)
1,11 17,9
.375-16 UNC-2B or M10-.750 thd., 4 holes (.44) (.07)
Uses FL1-6 series flange.
23,8
(.94) ∅ 101,6 (4.00)
70 101,5 (3.99)
(2.75)
34,9
(1.38)
47,6
(1.87)
∅ 19 (.75) outlet ∅ 38,1 (1.50) #1 Shaft shown
inlet For shaft options see pages 29 & 30.
.500-13 UNC-2B 21 (.83) deep, 4 holes.
Uses FL1-12 series flange.
155,4
(6.12) 58,7
132,6
∅ 14,2 through 2 holes (5.22) (2.31)
(.56) 63,5
146
C (2.5) ∅(5.75)
9,5 4,75 x 31.5
(.375) (.187 x 1.25) key
76,2
(3.0) ∅ 22,3 (.875)
22,2 (.874)
B D
55,4 50,8
(2.2) 27,9 (1.10)
(2.0) ∅ 27,6 (1.09)
25,5 (.966)
12,7 24,4 (.961)
A (.50)
Alternate cover positions
19
25V, 35V, 45V Installation Dimensions
H J D
∅F
Inlet ∅G, SAE flange pad with
four mounting holes. E
∅K:
25V pumps use FL-12 flange
35V pumps use FL-16 flange
45V pumps use FL-24 flange For mounting bracket dimensions see page 34.
Q
For shaft options see pages 29 & 30.
L For metric pilot flange dimensions see page 31.
M ∅T
∅X
S
∅N
RU
R ∅V
P
∅W
20
2520V, 35**V, 452*V Installation Dimensions
J E ∅F
Outlet No. 2 ∅K A
Outlet No. 1 ∅D
See port flange kits and mountigs for G
double pumps on page 23.
Y
Z
∅X
45 S
N P Q ∅U
R
∅L T
D
RW
M
For mounting bracket dimensions see page 34. ∅V
Nominal port size, also see next page “port flange kits and mountings for double pumps.
21
2525V, 4535V Installation Dimensions
J ∅F
Outlet No. 1
1.31” -12 UNC-2B
str. thds.
Outlet No. 2 ∅K Y
B
Inlet ∅H
Outlet No. 1 ∅D
S ∅X
Outlet No. 2
1.31” -12 UNC-2B str. thds. M ∅U
N P Q
148
(5.83)
T R ∅L
Model P Q R S T ∅U ∅V RW ∅X Y Z
2525V 101,6 38,1 76,2 263 84 146,1 175 14 174,7 26,2 52,4
(4.00) (1.50) (3.00) (10.4) (3.31) (5.75) (6.88) (0.55) (6.88) (1.03) (2.06)
4535V 133,3 42,9 93,7 353 102,4 181 148 – 213 30,2 58,7
(5.25) (1.69) (3.69) (13.9) (4.03) (7.13) (5.83) (8.38) (1.19) (2.31)
4535VS & 144 364
4535VM (5.66) (14.3)
22
Port Flange Kits / Mtg for Double Pumps
23
**VT Thru Drives Installation Dimensions
N
K
J
M ∅H
S
∅Z Outlet port P
R
AA
Q For shaft options see pages 29 & 30.
∅D
A
B C E
F
G
Model A B C ∅D E F G ∅H J K L M N
25VT See 111,1 38,1 174,8 87,4 76,2 84,1 101,6 (4.00) 52,4 26,2 50,8 88,9 44,5
page . (4.38) (1.50) (6.88) (3.44) (3.00) (3.31) 101,5 (3.99) (2.06) (1.03) (2.00) (3.50) (1.75)
35VT See 122 38,1 213 106,2 82,6 88,9 127,0 (5.00) 58,7 29,4 61,9 106,4 53,2
page . (4.81) (1.50) (8.38) (4.18) (3.30) (3.50) 126,9 (4.99) (2.31) (1.16) (2.44) (4.19) (2.09)
45VT See 129,9 42,9 213 106,2 93,7 102,3 127,0 (5.00) 69,9 34,9 69,9 120,7 60,3
page . (5.11) (1.69) (8.38) (4.18) (3.69) (4.03) 126,9 (4.99) (2.75) (1.38) (2.75) (4.75) (2.38)
Model P Q R S T U ∅V ∅W ∅X Y ∅Z AA
25VT 9,52 12,7 26,2 13,1 25,4 73 146 120,6 63,5 .500-13 UNC-2B 25,4 .375-16 UNC-2B
(0.375) (0.50) (1.03) (0.52) (1.00) (2.88) (5.75) (4.75) (2.50) or M12 thd. 23,8 (1.00) or M16 thd. 20,1
(.938) deep (0.79) deep
4 holes 4 holes
35VT 12,5 15,7 30,2 15,1 30,9 90,5 180,9 147,6 76,2 .625-11 UNC-2B 31,8 .437-14 UNC-2B
(0.49) (0.62) (1.19) (0.59) (1.22) (3.56) (7.13) (5.81) (3.00) or M16 thd. 30,0 (1.25) or M16 thd. 30,0
(1.18) deep (1.18) deep
4 holes 4 holes
45VT 12,5 15,7 35,7 17,9 35,9 90,5 181 147,6 88,9 .625-11 UNC-2B 38,1 .500-13 UNC-2B
(0.49) (0.62) (1.41) (0.70) (1.38) (3.56) (7.13) (5.81) (3.50) or M16 thd. 30,0 (1.50) or M12 thd. 22,2
(1.18) deep (.875) deep
4 holes 4 holes
24
**VT Thru–Drive Rear Mountings Installation Dimensions
A"
To mounting flange
133,2 face
(5.25)
66,6 6,53
(2.62) (.257)
Ø 82,63
(3.25) Ø 50,8
(2.00)
66,6
(2.62)
53,19 45°
(2.094)
Dimension A"
NOTE: This unit accepts a hydraulic
pump which conforms to flange and
Pump Dimension
**VTAS Models **VTAM Models shaft codes specified in ISO 3019/1
Model L"*
(SAE J744 Jul88).
32,6/31,0 Flange Shaft SAE
25VTA 236,5 (9.3) 236,5 (9.3) (1.28/1.22) Code Code J744C (Ref)
33,0 (1.30) 82Ć2 16Ć4 A
Maximum
32,6/31,0
(1.28/1.22) **VTA
35VTA 259,1 (10.2) 259,1 (10.2)
The following Vickers shaft selection
35,6 (1.40) will comply with the above:
Maximum
32,6/31,0 Rear Pump
(1.28/1.22) Model Shaft
45VTA 291,6 (11.5) 321,8 (12.7)
35,3 (1.39) V10 Vane pump 11
Maximum V20 Vane pump 62
PVB5/6 Piston pump S124
* Caution: Dimension L" is important and must be observed.
25
**VT Thru–Drive Rear Mountings Installation Dimensions
.500Ć13
Output
UNCĆ 2B thd.
coupling
19,30 (.760)
Ø 174,8 13T 16/32
thru flange 2 (6.88) A"
To mounting flange face DP Spline
holes (inch
threads)
9,78
(.385)
5,6
(.23)
66,7
(2.62)
101,68
Ø
(4.003)
Ø 56,6
(2.23)
133,4
(5.25)
84,1
(3.31)
Snap ring
L" AS 568Ć230
OĆring req'd
73,02
(2.86)
146,05
(5.75)
26
**VT Thru–Drive Rear Mountings Installation Dimensions
Output
coupling
Ø174,8 A" 13T 16/32
(6.88) To mounting flange face DP Spline
10,16
Snap ring (.400)
66,7
(2.62)
Ø 101,68
(4.003)
63,5
(2.50)
133,4
(5.25) 84,1
(3.31)
AS 568Ć155
OĆring req'd
Dimension A"
NOTE: These units accept a Vickers
Pump Dimension pump as below which conforms to
**VTBPS **VTBPM flange code 101Ć2 in ISO 3019/1 (SAE
Model L"*
J744C Jul88) and has a Vickers type 9
shaft.
45,6/43,2
25VTBP 261,9 (10.31) 261,9 (10.31) (1.80/1.70)
**VTBP
Not SAE std. The following Vickers shaft selection
will comply with the above:
45,6/43,2 Rear Pump
35VTBP 284,5 (11.20) 284,5 (11.20) (1.80/1.70) Model Shaft
Not SAE std.
PVE12/19/21 Piston pump 9
45,6/43,2
45VTBP 317,0 (12.48) 347,2 (13.67) (1.80/1.70)
Not SAE std.
27
**VT Thru Drive Rear Mountings Installation Dimensions
Ø 212,9
(8.38)
180.98
(7.125) 90,49 A"
(3.56) To mounting flange face
13,2
(.52)
.625Ć11
UNCĆ2B thd.
36,78 (1.45)
thru flange 2
holes (inch
threads)
Ø127,08
(5.003)
Ø 60,45
(2.38)
84,1
(3.31)
Snap
ring
AS 568Ć160
OĆring req'd
28
Optional Shafts
∅D
29
Optional Shafts
Splined Shafts A
D
∅E
30
Optional Shafts
45 Size Pumps
45VM Single Pumps
45VT*M Thru-drive Pumps
45**VM Double Pumps
To end of “A”
pump body
73,2
(2.88) 266,7
(10.5)
45VM Adapter Flange 200,2
Ø (7.88)
See Shaft Options
on pages 29 & 30.
22,0 (.866)
9,12 Ø thru 2 places
23,8 Stamped “M”
(.36)
(.94) 224,0
(8.82)
160,0 (6.299)
Ø 159,9 (6.297)
45VT** Thru-drive Pumps Dimension “A”
Rear Mounting Type 45VT*S Pumps 45VT*M Pumps
31
Torque Loading for Direct Drives
25VS
A 131 (1160)
Input Torque (Nm)
32
Drives
33
Foot Mounting Bracket Option
B G
rQ
ØL Pump
mounting surface
D ØN
ØP
C
F ØL1
H J K R
A A
Part No. A B C D E F G H J
422583 171 178 92 181 93 98 17,4 13 146
(6.75) (7.00) (3.625) (7.125) (3.656) (3.858) (.687) (.50) (5.750)
422584 265 212 109,5 216 129 164 19 16 235
(10.43) (8.37) (4.312) (8.50) (5.06) (6.46) (.750) (.62) (9.250)
34