Fill detail for all yellow color boxes and click apply.
Device IP, Subnet Mask and Default Gateway and Network Management VLAN ID, – use DCN IP address and Management VLAN
provided by Microwave Engineer.
Note: Please don’t use BTS/Node B IP addresses and VLAN. In all attached snapshot, IP mentioned are just for reference
purpose only
Below attached screen is the reference how to mention Site ID(xxx001) and NE Name ( xxx001-
xxx002). NE Name should start first with Site ID of site which you are configuring and XXX002
should be other End of this site.
6- Security SNMP
Name: EMSSERVER1
IP Address: xxx.xxx.xxx.xxx (use IP address provided by Microwave Engineer)
Status: Enable.
Name: EMSSERVER2
Below window will appear. In this window, define Bandwidth, Modulation, Power and Frequency.
a> In Transmission unit Name, under drop down, two Unit will show,
TN5-1- Unnamed and TN6-1-Unnamed indicated two Modems. (TN5-1 will be used, so there is no need to change it).
Name: SITEA-SITEB (Use Site A ID and Site B ID). { First end(SITEA) should be Site ID of this site which you are configuring}
a> Select Port which you want to configure by clicking on that part, after clicking, it will highlight as shown below for NMS port :-
Below example shows how to enable another port – GbE1 (procedure is same as we enable NMS port in above scenario).
Select Port by selecting it and after this, it will highlight as shown below.
After this, Click Modify, below window will appear:-
Change Status – Enable.
Duplex Mode – Full – Duplex.
Auto Negotiation Status – Enable.
Speed – 1000(or as per Port requirement).
Port Description – Give port description as per usage.
Similarly, we can enable other ports as per requirement. Below screen depicts that GbE1, GbE2 and NMS port are enabled.
After enabling the ports, you can check the status of ports when LAN/Patch Code will be inserted into these ports from Port
Status.
All VLANs which are configured on different ports should be added on AIR-5-
1 or AIR-6-1 port (depending on which modem card is used) in the same
manner.
Below example shows that VLANs are configured at GbE5/10GbE, AIR-5-1
and at GbE2.
For Login to Far end , Change the port from LMT to NMS and set IP address in
your laptop of same gateway(Free IP of same pool).
Then open browser and put Far end IP and login into it.