You are on page 1of 10

MINISBARRE (MS)

BUSBAR
63, 100 AND 160 A
The compact MS (Mini busbar) is the smallest range of the
medium power range, ideal for the powering of
solution for lighting bodies in small-medium companies.
Thanks to its characteristics, and the wide range
medium power of accessories and tap-off boxes available, the
MS range is the best compromise in all the
distribution medium power applications of the service sector.
With the MS range, there is absolute confidence
that the power is distributed in a safe way, with
the best performance.

Range
The main features of the MS range are: WIDE RANGE OF TAP-OFF BOXES QUALITY MATERIAL
speed, simplicity, and flexibility during The range of tap-off boxes of the MS Each system component is made using
the installation and the design of the busbar family is capable of meeting all high quality materials, in compliance with
paths; the needs of the customer. the technical and safety requirements
strength, in spite of the compact sizes; of the standards. During each
availability of tap-off boxes with internal manufacturing process stage, maximum
SIMPLE INSTALLATION
room for up to 16 DIN modules; attention is given to each and every
The busbars and the accessories making element.
compliance with the IEC 61439-6 up the system can be installed very easily.
standard;
reference room temperature 40 °C. FAST AND SIMPLE CONNECTION
the whole busbar is “fire retardant” in The connection between straight
accordance with EN 60332-3. elements is simple and quick. With one
simple operation, it is possible to obtain
both the electrical and the mechanical
connection, ensuring at the same time an
IP40 protection degree. The application
of a sleeve on the joint and a shutter for
each window (without box), gives the
possibility to increase the protection
degree to IP55

32
LABORATORIES SMALL OR MEDIUM FACTORIES

Installation fields
The MS range is widely used in labs, small to medium
companies, warehouses, and in all the service sector
structures, where there is a need for electric power
distribution for medium power systems.

Installation accessories

Intermediate feed unit Flexible joint

Tap-off boxes IP55 kit sets Tap-off boxes

33
TRUNKINGCOMPONENTS
AND
ADDITIONAL
ELEMENTS

Feed units. Joint cover. Tap-off box complete with terminals


It ensures the IP55 for cables of up to 25 mm2. Made from
degree of protection self-extinguishing plastic material, high
of the junction. mechanical resistance and resistance
to static currents. The Box can be
connected and disconnected when
energized. Capacities from 16A to 32A.

Depending on the different installation requirements d) straight elements with flame barrier (internal +
Legrand range can provide various technical solutions: external). These elements - used when it is necessary
to move through fire-resistant walls - have been tested
in laboratories (in compliance with DIN Standards
a) 90° angles: available for carrying out changes of
4102-9 and EN 1366-3) to confirm that,
direction both horizontally and vertically. There is a
if correctly installed, they can maintain the intrinsic
quick connection, as with the straight elements.
fire-resistant properties of the wall;
The standard is IP40 degree of protection (to reach
IP55 is necessary include the specific accessory);
e) Vertical Installation (riser mains)*
b) T-type and X-type elements: available on request for straight elements with bar lock: when the busbar is
special applications; installed vertically (riser mains) these elements are
equipped with a device that prevents the conductors
from sliding due to the weight of the portion of column
c) flexible angle: available for 63A, 100A and 160A over it. This type of element is required at about every
capacities and allows changes of direction with angles 10 m of column.
different, horizontal and vertical, from 90°;

* For this quotation please contact Legrand

34
Wall suspension Straight elements, End cover:
bracket or bracket with tap-off outlets completes the
for connecting a every 1000 mm from installation of the
support. both sides. lines and guarantees
the IP55 degree of
protection of the line.

35
Minisbarre (MS) 63, 100, 160 A Minisbarre (MS) 63, 100, 160 A
trunking components feed units

51511052

51511151

Pack Cat.Nos Feed units


51530351
MS63 (63 A) MS100 (100 A) Description Type
51500461
2 51511051 51511051 Right
Head
2 51511052 51511052 Left
1 51511151 51511151 Intermediate
MS160 (160 A)

1 51521051 Right
Head
1 51521052 Left
1 51521151 Intermediate
51511261
Note: RH-Right, LH-Left
Reference standard: IEC 61439-6
Reference temperature: 40 °C
Degree of Protection: IP 40/55
Thickness: 0.8 mm;
Dimension: 39x97mm;
N° of conductors: 4 with equal section 3P+N
Conducting «fire retardant» in accordance with EN 60332-3
Separation between the conductors by plastic insulators
reinforced with 20% glass fiber, which guarantees a degree
of V1 self-extinguishing (according to UL94) and conform
to the glow-wire test according to IEC 60695-2-10

Pack Cat.Nos Straight elements


MS63 (63A) MS100 (100A) MS160 (160A) L (m) Outlets

1 51530101 51510101 51520101 3 3+3


1 51530116 51510116 51520116 2 2+2
1 51530115 51510115 51520115 1.5 1+1
1 51530114 51510114 51520114 1 1+1
1 51530112 51510112 51520112 <1.5 *
1 51530113 51510113 51520113 >1.5 *
Flexible joint
(elbow) - IP55
MS63 MS100 MS160

1 51511261 51511261 51521261 Flexible joint


Elbows - IP55
MS63 MS100 MS160 Type

1 51530351 51500361 51520351 Right


Horizontal
1 51530361 51500362 51520361 Left
1 51530451 51500461 51520451 Right
Vertical
1 51530461 51500462 51520461 Left
*Outlets to be defined in base of the length of element

36
Minisbarre (MS) 63, 100, 160 A
trunking components and feed units

n Dimensions
MS63 - MS100
A d 1= 165 273 8
MAX Ø 55
865 1000 1000 135 230

10
125
230 135 1000 1000 865 10
LH RH Cable max
Section 35 mm2

85
Weight
In (A) Item code A (m) (kg)
51530101 3 7.890
L1 51530116 2 5.260 Item code Weight (kg)
N 51530115 1.5 3.945 51511051 (RH) 1.732
63
97
70

L2 51530114 1 2.630 51511052 (LH) 1.874


51530112 < 1.5 -
L3
51530113 > 1.5 -
51510101 3 7.890 MS160
51510116 2 5.260
39 n° 2 d 1= 200 273 8
51510115 1.5 3.945 MAX Ø 63
100
51510114 1 2.630
51510112 < 1.5 -

13
51510113 > 1.5 -
51520101 3 9.290 211 16
51520116 2 6.190
LH RH Cable max
51520115 1.5 4.645 Section 70 mm2
160
51520114 1 3.100
118

51520112 < 1.5 -


Horizontal elbow 51520113 > 1.5 -

10
Right
135
365 Item code Weight (kg)
10
51521051 (RH) 2.218
8 Cable max
51521052 (LH) 2.360
Section 35 mm2

Versions with switch disconnector are also available on request


N

In (A) Right Left Weight (kg) Intermediate feed unit


63 51530351 51530361 1.600 MS63 - MS100
Left 100 51500361 51500362 1.600
135
160 51520351 51520361 2.600 8 273 270 273 8
365
8 n°2 d 1=
MAX ø 55
10
180

10
RH and LH elbows are different in Cable max
the position of the joining block.
N n°2 d 1= MAX ø 55 Section 35 mm2
Vertical elbow
100

Right Left
135
8

N Item code Weight (kg)


51511151 3.500
365

N
365

MS160
135
8 273 400 273 8
8

Weight n°2 d1=


In (A) Right Left (kg)
MAX ø 63
13

63 51530451 51530461 1.600


100 51500461 51500462 1.700
200

16
160 51520451 51520461 2.700
Cable max
Section 70 mm2
n°2 d1= MAX ø 63
Flexible joint (Art. 51511261 and 51521261)
615
8 246 246
112

190

10

10
95

Item code Weight (kg) Cable max


Section 35 mm2
69 216 69 51521151 5.000
354

864

37
Minisbarre (MS) 63, 100, 160 A Minisbarre (MS) 63, 100, 160 A
tap-off boxes tap-off boxes

n Dimensions
1 2

97

97
51515071 51515074

d1 MAX = 38

d1 MAX = 38
160
160
Pack Cat.Nos Tap-off boxes
Type and description In (A)
1 51515071 1 Empty with 4 module DIN rail 32 150 250
1 51515076* 1 With fuse carrier CH10 (10.3x38mm) 32
1 51515077* 1 With D01 fuse carrier 16
Item code Weight (kg) Energy withstand 400.000 A2s
1 51515078* 1 With D02 fuse carrier 32 Power loss 10 W
51515071 0.680 Total insulating Tap-off box
1 51515072 1 For 4 DIN rail modules cover junction 32 * Power loss 16 W
51515076 0.680
1 51515073 2 Empty with 8 module DIN rail 32 51515077 0.950

7
1 51515074 2 With 4 module DIN rail (long version) 32 51515078 0.950
1 51515075 2 With 8 module DIN rail (long version) 32 51515072 0.730
5.3
51515073 * 0.930
* Fuses not provided 51515074 * 0.960 Cable max
51515075 * 0.990 Section 16 mm2

Types of installable boxes

230

365
4 6
865

Type of tap-off boxes


1000

1 2 3
1 2 4 5 6

1 2 3
1000

4 5 6

51515071 51515073
3000

1 2
1 2 3
1000

4 5 6

1 2 3
1000

51515076 - 51515077 - 51515078 51515074 4 5 6

1 2
865

4 6
365

51515072 51515075

38
Minisbarre (MS) 63, 100, 160 A Minisbarre (MS) 63, 100, 160 A
tap-off boxes tap-off boxes

n Dimensions
Art. 51515051 Art. 51515052
In= 16 A In= 50 A
3 Item
code
Weight
(kg)
4

180
180
180
51515051 0.908

58 180

265
265
265
51515052 0.908

265
51515051 51515052

5858
58
* fuses not provided

180

8080
80

6060
60
80

265
60
160 160
160
160 cables
cablesinput
input

58
cables input
cables input
d1 = MAXd1ød129
d1
==MAX
MAX ø ø2929
= MAX ø 29
cables
cablesinput
cables input
cables
input
input

80
d1d1==MAX
MAX ø ø2929

60
160 d1 = MAX d1ø=29
MAX ø 29
cables input

144
144

123
123
d1 = MAX ø 29 cables input

144

9999
99
123
144

123
99
d1 = MAX ø 29
51515056 51515058 cables
cablesinput
input 225
225
cables input
cables input

144
225

123
d1d1==MAX
MAX ø ø2929 225

99
d1 = MAXd1ø 29= MAX ø 29
cables input 225
d1 = MAX ø 29
Cable
Cablemax
max Cable
Cablemax
max

5,5
5,5
Cable max

1010
10
5,5 Cable max Cable max 22 Cable
Section max
Section
3535mm
mm
2 2

5,5

10
Section
Section1010mm
mm Section 35 mm2 35 mm2
Section mm2 10 mm2
5,510Section
5,5 1010
Section
5,5 5,5 10 10 Cable max
Cable max

5,5

10
Section 10 mm2 Section 35 mm2
In= 63 A 5,5 10
51515067 5

365
365
Pack Cat.Nos Tap-off boxes with disconnecting device Cable
Cablemax
max

365
365

1010
10
Cable maxCable max
on cover Section
Section3535mm
mm
2 2

10
Section
1010 Section
35 mm 2 35 mm2

365
Type and description In (A)
130
130
110
110

10 10 Cable max

9090
90

10
130
130 110
130

2 51515051* 16
110

3 With fuses carrier CH10 (10.3x38mm) Section 35 mm2


90

10
2 51515052* 4 With fuses carrier CH14 (14x51mm) 50 Usable
Usableinternal
internal Item code Weight (kg)
110

space
space=internal
Usable
Usable internal =170
170 90 51515057 1.100
1 51515057 5 With transparent cover 63 space = 170 cables
cablesinput
input
space = 170 51515056 1.200
cables cables
d1
d1==MAX
input input
MAX ø ø5555
Usable internald1 = MAX ø 55
1 51515056 5 With
 transparent cover and 63 spaced1==170MAX ø 55 51515067 1.100
hinged window (4 modules) cables input Energy withstand 400.000 A 2S
132
132

d1 = MAX ø 55 Power loss 20W


120
120

1 51515067 5 With hinged window (7 modules) 63


120 132
120
132
120

1 51515058 6 With hinged window (16 modules) 63 cables


cablesinput
input
132

cables
d1
d1==MAX
cables input input
MAX ø ø5555
* Fuses not provided 260 d1 = MAXd1
260 = MAX ø 55
ø 55
260
283
283 cables input
260
283 d1 = MAX ø 55
283 260
283
In= 63 A
Type of tap-off boxes
6 Item code Weight (kg)
3 5 51515058 2.500
Energy withstand 400.000 A2S
Power loss 20W
600600
600

Cable
Cablemaxmax
10 10
10

Section
Section
Cable 3535mm
max mm
2 2
600

Cable
1010maxSection 35 mm2
10
600

Section
10 35 mm Cable2
max
10

51515051 51515057
10 Section 35 mm2
10

cables
cablesinput
input
4 5 d1
d1==MAX
cables MAX
inputø ø5555
10,5
10,5

cables input
d1 = MAX ø 55
10,5

d1 = MAX øcables
55 input
10,5

Open
Open
d1 internal
=internal
MAX transparent
ø transparent
55
10,5

cover:
Open max
cover: max135
internal 135 mmmm
transparent
Open internal
cover:transparent
max 135 mm
128128
128
100100
100

Open
cover: max 135 mm internal transparent
100 78 78
78

cover: max 135 mm


128
100

128
78

51515052 51515056 520


520
78

520
520
6 5 520
155155
155
155

155

290
290
487
487290
290 511
511
487 290
487 511487
51515058 51515067
511 511

39
Minisbarre (MS) 63, 100, 160 A Minisbarre (MS) 63, 100, 160 A
installation accessories and Fire Barrier installation accessories

n Dimensions
End cover 51501351
310

51501351 51002002

42
51500161 51500160
IP55 joint cover 51500161
Pack Cat.Nos Installation accessories 310

1 51501351 End cover


5 51500161 IP55 joint cover (one set for each junction)
12 51500160 IP55 outlet cover (6 every 3m straight element)
10 51002002 Suspension bracket (1 bracket every 2 metres)
Kit Fire Barrier E120
42

1 515EFB01 External Kit fire barrier (63A-100A-160A)


1 515IFB01 Internal Kit fire barrier (63A-100A-160A)

Outlet cover 51500160

82

Suspension bracket 51002002

80 7x11
7x11

7x11
131

64

7x11
68 20

Ø7

40
Minisbarre (MS)
technical informations

n Straight elements Minisbarra (MS)


The components and the features of the MS straight elements are: 63 100 160
• a casing made of quality galvanized steel, with a sheet-metal N°of live conductors 4 4 4
thickness that allows its use as the protective earth (PE) and ensures Overall dimension LxH [mm] 39x97 39x97 39x97
the electrical continuity during mounting with no added accessories; of the busbars
• overall busbar dimensions: 39x97mm; Rated current In [A] 63 100 160
• number of conductors: 4 with the same cross section Operational voltage Ue [V] 400 400 400
3P+N available for capacities 63A, 100A and 160A;
• separation between the conductors using plastic insulating Insulational voltage Ui [V] 750 750 750
devices, reinforced with 20% of glass fibres, which are able to Frequency f [Hz] 50/60 50/60 50/60
ensure a V1 selfextinguishing degree (according to UL94) and are Three phase rated
in compliance with the glow-wire test according to IEC 60695-2-10; Icw [kArms] 3,5 5 5,5
short-time current (0,1 s)
• tap-off outlets with a constant centre distance of 1 m Three phase Ipk [kA] 5,25 10 10
on both sides of the busbar (3+3 windows every 3m), peak current
set up for being connected to tap-off boxes; Thermal limit I²t [A²s x 10 ] 1,23 2,5
6 3,03
• an electric joint block, with silver-plated copper contacts for Phase resistance R20 [mΩ/m] 1,250 0,837 0,478
automatically connecting live parts and the PE (protective conductor). at 20 °C
The connection between two straight elements is Phase resistance at Rt [mΩ/m] 1,445 1,078 0,650
quick; with one operation it is possible to have thermal conditions
an electric and a mechanical connection; hence, at Phase reactance X [mΩ/m] 0,366 0,247 0,247
the same time, an IP40 degree of protection is at 50 Hz
guaranteed. The upgrade to IP55 is easily obtained by Phase impedance Z [mΩ/m] 1,302 0,873 0,538
adding joint covers and outlet covers. The whole duct is fire
retardant in compliance with the IEC 60332-3 standard Resistance of protective RPE [mΩ/m] 0,857 0,857 0,857
conductor (sheet)
Reactance of the XPE [mΩ/m] 0,102 0,102 0,102
n Fixing support protective bar at 50 Hz
In order to attach the line to the structure of the building, Resistance of Ro [mΩ/m] 2,11 1,69 1,34
directly or with wall supports, it is necessary to use a bracket the fault loop
which serves as a collar around the busbar. The bracket has Reactance of Xo [mΩ/m] 0,468 0,349 0,349
holes to be easily paired with the available supports the fault loop
Impedance of Zo [mΩ/m] 2,16 1,73 1,38
n Tap-off boxes the fault loop
Used to connect and energize one-phase and ΔV 10 cosϕ = 0,7
-3
[V/m/A] 1,102 0,806 0,547
threephase loads up to 63A; their features include: ΔV 10 -3 cosϕ = 0,75 [V/m/A] 1,148 0,842 0,564
• the PE contact (protective earth) is the first to make an ΔV 10 -3 cosϕ = 0,8 [V/m/A] 1,191 0,875 0,579
electrical connection when inserting the box into the outlet Voltage drop with
distribuited load ΔV 10 -3 cosϕ = 0,85 [V/m/A] 1,231 0,906 0,591
and it is the last to disconnect when pulling it out; referred to V3f(*)
• compliance with all insulating plastic components ΔV 10 -3 cosϕ = 0,90 [V/m/A] 1,264 0,933 0,600
according to the glow-wire test (IEC 60695-2-10) ΔV 10 -3 cosϕ = 0,95 [V/m/A] 1,288 0,954 0,602
with V1 self-extinguishing degree (UL94); ΔV 10 -3cosϕ = 1 [V/m/A] 1,251 0,934 0,563
• standard IP55 degree of protection without Weight 2,0 2,5 2,8
p [kg/m]
using additional accessories;
• can be inserted and removed when the busbar is energized Fire load [kWh/m] 1,64 1,64 1,64
and when the fixure is under load, up to a capacity of 32A. Degree of protection IP 40/55 40/55 40/55
These boxes are available in a wide range of versions: Losses for the Joule P [W/m] 17,21 32,34 49,93
• 63A empty boxes (only with a terminal board for effect at nominal current
connecting cables), with an internal DIN rail and Ambient temperature t [°C] -5/50 -5/50 -5/50
transparent door; min/MAX
• 16A - available with a set of three cylindrical
fuse carriers CH10 (10.3x38mm);
• 16/32A - available with a set of three cylindrical
fuse carriers - DIAZED (D01: 16A; D02: 32A); (*) THREE-PHASE: ΔV3f= √3/2 x (Rt cosϕ+ X senϕ)
• 50A – available with cylindrical fuse carriers (14x51mm); ΔV3f(In)=I x L x ΔV3f: (knowing
• 63A – available with 4-7-16 DIN modules;
• 16 to 63A – available with a disconnection the current and length of the line)
device integral with the cover ΔV3f(In)%=(ΔV3f(In) / Ue) x 100 (%)
To calculate the ΔV1f (SINGLE-PHASE) on distributed load:
n Feed unit ΔV1f= 1/2 x (2Rt cosϕ+ 2X senϕ)
ΔV1f(In)=I x L x ΔV1f: (knowing
Allows you to electrically power the MS line through a cable line;
the installation is carried out with a quick junction connection the current and length of the line)
as with the straight elements. The feed units have terminals for ΔV1f(In)%=(ΔV1f(In) / Ue) x 100 (%)
the connection of copper cables for sections of up to 35 mm2
for the 63/100A feed unit and 70 mm2 for the 160A feed unit I = operating current (A)
The entrance point of the cables is positioned on the back L = lenght (m)
side of the feed unit. The MS line offers also central feed units
as well as power supply boxes with a switch-disconnector
which allows you to select the whole line for carrying out
maintenance operations or layout changes, if required

n End cover
The end cover ensures the IP55 protection degree at the
end of the line

41