APPARATUS : Standard balance of accuracy 0.1 gram, Brush, 90 micron sieve, stop watch.
PROCEDURE :
Break down any air-set lumps in the cement sample with fingers and at a rate of pull
of 50.0 ± 2.5 mm/min.
Weigh accurately 100 gm of the cement and place it on a standard 90 micron IS
sieve.
Weight the residue left after 15 minutes of sieving. This completes the test. 1).
CALCULATIONS :
The percentage weight of residue over the total sample is reported.
LIMITS :
As per IS the percentage residue should not exceed 10% for OPC and 5% for PPC.