You are on page 1of 5
PT. WUAYA KARYA (PERSERO) TBK. JAKARTA-BANDUNG HIGH SPEED RAILWAY PROJECT TECHNICAL PROPOSAL STEEL SHEET PILE WALL DK 88+080 CLIENT FILE DATE IBHSR Steel Sheet Pile Wall DK 88+080 March 5, 2021 Design by Checked By ‘Approved By (Wukammed Remedanil | (Ridwan Fachrulrozil_| (Hates Adityo Nagorol (Sudiyatmakol Engineer Chief Engineer Construction Manager | Deputy Manager Project REV DESCRIPTION DATE March 5, 2021 TACULaTION HET (Wilt A, STREET Pur wa iegect—_—TRCEHTA = BaDUNE SPEED FaLwav PHORCT [fav Taya vary ese] Tk JekatT ae ST 1. GENERAL 1.1 OBJECTIVE The objective of this calculation is to design the sheet pile wall for excavation protection on Slope of Box Traffic Subgrade 338.2 Jakarta-Bandung High Speed Railway Project 1.2 PROJECT DESCRIPTION Project Name: Jakarta-Bandung High Speed Railway Project Lokasi Walini, Jawa Barat 2, REFERENCE 2.1 STANDARDS AND CODES Bowles, J. E. (1997). Foundation Analysis and Design (5* ed. Singapore: McGraw-Hill 22 DATA 1. Design criteria and material specification 2. Technical Drawing 3. Soil Investigation Data PT. yaya arya (Percerl Tok TACULaTION HET Tite TEL HET ue wa TR raat TAREHTA ~ Bane Wen SPEED Rau way PRUECT —[ fey —— or Jaka8 Tate 3. DESIGN CRITERIA 3.1. TYPICAL STRUCTURE DESIGN The design ptotection wall can be seen in figures below: aggftfe wad 2 OB gl se BSS 4 a Figure 1 Secant Pile Design Soil properties based on Bore Log 16-20-439. 3.2 SOIL PARAMETER Depth Parameter Soil Description ot | Son (on) € s E v 0 |=] 89 | Clay, dark brown 20 50 | 4000 | 035 6 % 59 [-| 1 | Clay. dark grey 5 | 32.806 | 68333 | 03 6 % 0 [=| 1 | Clay, dark grey 5 | 363" | 67 | 03 6 % 18 [| 20 | Clay, dark grey 5 | 421e | 20500 | 0.3 6 % 20 [=| 30 | Caystone 5 467 | 296667 | 03 8 6 Wi eaters raat TEKERTA ~ BRMDONE WH SPEED Rana PROECT [fey —~ or PT. yaya Kaya (Perse) To Jaka8 Tate 3.3 STEEL SHEET PILE WALL PROTECTION PARAMETERS Plate properties, x /-Nateral se roperties Identification: [sp eA: 32506406 bnim Material type: [Elastic a et: 28608404 pint\m (325m 1 vs [5300 Anirym vi fo,t50 My: FROOOESIS’ nm Nye [ROOOEHIS’bnim Rayleigh: [0,000 Rayleigh p: [0,000 4. STRUCTURE MODEL AND ANALYSIS 4.1 PILE PROTECTION CALCULATION MODEL This analysis is done by using Plaxis 20 82 Figure 2 Structure Model in Plaxis, The working stage of this analysis are as follows: 1. Steel Sheet Pile wall 2. Excavation work TEL HET ue wa TR CD = raat TEKERTA ~ BANDUNG HEH SPEED Ra Way PEOECT PT. yaya arya (Percerl Tok Jaka8 Te Tate 4.2 MODEL ANALYSIS OUTPUT The output of this model analysis are as follows: "Pacis 8.2 Caleulations ~ 55° Jembatan akses B.ph: Fle Edt View Calculate Help SBS eg oH tom Gerard | parometes | Uivies| Preven | rae colin te vane 0 FT So on ce =] bene et [Prescrbed inate vate nat eachet Soleo colar Inepectaupaterd cad deplcenent carve Parameters Binet a Boe aeration [se iz TF ritdchese 0 0 oan t Q pasie staged conection aon. 1 opian tohep 1 2 1 Plastic: ‘Staged construction 0,00 2 € Ke + 2 lsc staged constuction ono. 4 ¢ Vo 5 Q Phieredcon srremertal mls ono. 0 Figure 3 SF Value = 1921 5. CALCULATE OF ANALYSIS 1. Not possible to use steel sheet pile wall on this protection 2. Steel sheet pile not support for material on protection because weight minimum 15 ton 3. The length of steel sheet pile of 12m and exposed 4,6m

You might also like