You are on page 1of 1

LEGEND

A B C A B C
NOTES

3787.50 3787.50 3787.50 3787.50

112.50 112.50
1

1
L= 7775 mm T 16 @ 200 C/C

2025.00 2025.00 2025.00 2025.00

L= 6050 mm T 12 @ 300 C/C


2

2
AA AA

6050.00

3825.00 3825.00 3825.00 3825.00


7750.00
150.00

7800.00

SEC AT AA
T16 @ 200 C/C
T12 @ 300 C/C
3

3
T16
T16

L= 4875 mm T 12 @ 300 C/C


ld = 160 mm

225.00
T8
225.00
200.00
T8

L= 2225 mm T 16 @ 200 C/C

4125.00 4125.00 4125.00 4125.00

4875.00
L= 5750 mm T 16 @ 200 C/C
4

4
75.00 150.00 4025.00 3725.00

L= 9750 mm T 12 @ 300 C/C


525.00 525.00 525.00 525.00

9725.34
5

5
1462.50

L= 5075 mm T 12 @ 300 C/C

L= 1937.50 mm T 12 @ 300 C/C


4875.00 4875.00 4875.00 4875.00

L= 2225 mm T 16 @ 200 C/C Residential Building


1350.00
1937.50
1937.50 TYPE - B
2262.50
6

6 Kingdom of Saudi Arabia


National Guard
Engineering Services
Planning & Design Dept.
Health Affairs King Abdulaziz Medical City

3787.50 3787.50 3787.50 3787.50

TOP Beam D:\work\SAUDIA\AHMED EL NASBAN\gada\work2\autocad\‫\لواو جلا ولول‬nasban logo.jpg

Drawing Name

Top Beam And Slab Reinforcement


Arch. Civil Elect. Mech.

Beam Schedule Slab Schedule SCALE: 1:1

Dwg.No: 07 34 KFH S00


Beam Name Size Bars Dia of Steel Spacing Bend /DL Slab Name Bars Dia of Steel Spacing Bend /DL
Contractor: Pamcon GROUP Signature
B3 225x225 Longitudinal Bars 16 mm 160 mm S1 Main Bars 16 mm 200 C/C 50 mm
REVIEWED BY:
B3 225x225 Stirrups 8 mm 200 C/C 80 mm S1 Distribution Bars 12 mm 300 C/C 50 mm
Name ENG - Ayaz Sadiq

Date 06 / 03 / 2020

Signature

CONSULTANT

Proj.Manager approved

Name approved as noted

Date correct & resubmit

Signature rejected