LEICA NA2 • NAK2

Universal automatic level


LEICA NA2
The classical level from Leica Geosystems

The NA2 universal auto- Universal application • Tacheometric levelling


matic level meets all with the K-version on flat
requirements regarding • Levelling of all types and terrain by combining
precision, convenience all orders of accuracy stadia and angular meas-
and reliability. urements with height
• Precise levelling and readings
It was designed by sur- settlement determinations
veyors and development on buildings • Deformation measure-
engineers with years of ment and monitoring of
experience and who know • Routine heighting for bridges
what a field instrument the construction of roads,
has to be able to do. railways, pipelines,
tunnels and so forth
The NA2 soon pays for
itself, because it can be • Setting-out work and
used for all types of sur- control measurements on
veying job; on building the construction site
sites for routine levelling,
in engineering projects, • Area levelling of high
and for geodetic control at accuracy
all levels of accuracy.
Quickly set up, simple to use

Strong tripods Centring is easy Play-free footscrews Independent of


temperature
In principle, the NA2 The circular level only The pitch of the smooth-
can be set up on any Leica needs to be centred running and backlash-free Unlike the tubular level of
Geosystems tripod. In approximately to bring the footscrews is such that a traditional instrument, the
practice, for all-round compensator well into its the bubble can be centred NA2 universal automatic
purposes, we recommend working range of ~30', and in a very short time. level is relatively insensitive
the heavy-duty GST20 so setting-up goes quicker. to direct solar radiation
telescopic-leg tripod. and an umbrella need only
For precise levelling the The bubble is viewed be considered for the most
GST40 fixed-leg tripod positively via a pentaprism precise levelling.
is suitable because of its and is monitored down
extreme rigidity. the eyepiece.

The modular relationship


between instrument and
tripod is an advantage
when transport space is
limited.

Open sight

Rapid / fine focusing knob

Pentaprism for viewing circular level

Push-button for compensator control


Endless horizontal drive
Endless horizontal drive

Footscrew Footscrew
Adjust the line of sight automatically

Easy to level up Robust and automatic Minimum maintenance

The advantage of this The compensator is In the unlikely event that


instrument is that, as soon essentially a pendulum the compensator is
as the bubble is centred, with a prism (4). damaged (and this can only
the line of sight is horizontal happen as a result of
for all pointings of the The suspension system extremely harsh treatment)
telescope. The observer is comprises four flexed it is replaced easily, being
freed of the time-consuming tapes (1) made of a special held only by three screws.
centring procedure involved alloy to ensure faultless
with the traditional tubular functioning even at extreme
level, and can concentrate temperatures. The compen-
on the business of staff sator, which is located
readings. between the focusing lens
and the crosshair reticle,
is pneumatically damped
against mechanical vibra-
tion and is screened against
magnetic fields.

NA2/NAK2 compensator
1 Suspension tapes
2 Prism (fixed)
3 Compensator body
4 Pendulum with prism
5 Line of sight
6 Push-button
7 Spring which taps pendulum
8 Pneumatic damping mechanism

Push-button control – away and then float gently


added security back to give the horizontal
line of sight. This check,
With most automatics one which takes less than
taps the tripod or instru- a second, is technically
ment to check if the com- perfect, as the pendulum
pensator is functioning. itself is activated and
Leica Geosystems offers a swings through its full
far more sophisticated range. It is also immediately
solution. apparent if the bubble
is not centred.
Pressing the button under
the NA2 eyepiece gives the
compensator a gentle tap,
so that you see the staff
image swing smoothly
Top-class optics

Top-class optics Fatigue-free viewing

The telescope is of excellent The reticle has:


quality and gives a bright, – a single horizontal hair
high-contrast, erect image, for reading normal staffs
even in poor light – an – a wedge-shaped hair for
essential for accurate use with invar staffs
levelling. With the standard – stadia hairs for distance
eyepiece the magnification measurement and three-
is 32×, the optimum for wire levelling.
most applications of the
instrument. Optional The general layout of
eyepieces are available; the the controls, the smooth
40× may be preferred for friction-braked rotation
precise levelling, the 25× of the instrument, and the
in hot, shimmer conditions. endless horizontal drive
Eyepiece exchange takes with bilateral knobs,
only a second or so. all combine to make the
instrument easy to use.
The focusing knob has a NA2 field of view with metric levelling staff
coarse/fine movement: Reading at horizontal hair: 1.143 m
– coarse, for rapid setting
with minimum turning
– fine, for the final delicate
touch to give the perfect
image.

At an advantage on Angle measurement


unstable ground with the NAK2

If a tubular level is used Civil engineers and contrac-


on unstable ground it tilts tors often require a circle
out of range and has to be for angle measurement
continuously reset. By and setting-out work. Even
contrast, the pendulum of simple detail surveys, by
the NA2 “compensates” taking angle, distance and
and keeps the line of sight height, and plotting with
horizontal. the polar method, can be
NAK2
done with a level.
circle reading (400 gon)
392.66 gon
The model NAK2 has an
internal glass circle which
is read via a scale micro-
scope and which can be set
to any value by turning
the rim around the base
of the instrument.

NAK2
circle reading (360°)
314°42'
High-performance accessories for precise levelling

GPM3 GPM6
parallel-plate micrometer parallel-plate micrometer

This optional accessory There are tasks for which


slips over the telescope a micrometer is needed,
objective and blends yet for which the very high
perfectly with the smooth accuracy of the GPM3 is
lines of the NA2. With not essential.
a compensator setting
accuracy of ±0.3“ (equiva- To meet this requirement,
lent to 0.01 mm in 10 m) a simpler micrometer
and a micrometer reading attachment, the GPM6
to 0.1 mm direct and with drum reading,
0.01 mm by estimation, the is available for the NA2.
NA2 with GPM3 is an ideal
combination for precise The GPM6 fits on to the
levelling, deformation telescope objective in the
studies, and even optical same manner as the GPM3,
tooling. The micrometer but the graduation is
drive for raising and lower- engraved on a metal drum.
ing the line of sight is con-
veniently located and read-
ings are taken on a glass
scale viewed through an
eyepiece just above the
telescope eyepiece. This
optical reading system,
which is digital apart from
the last and estimated Eyepiece accessories for
figure in the metric and specialized tasks
inch versions, is superior
to the usual metal drum Because of the bayonet
system. fastening of the inter-
changeable eyepiece, all
theodolite eyepiece acces-
sories can be used with
the NA2.

• Diagonal eyepiece for


observing from above,
below, and from the side;
useful in cramped spaces

• Eyepiece lamp for con-


verting the NA2 into
a horizontal collimator
for laboratory work

• Autocollimation eye-
piece for setting machine
parts and instrument
components precisely
vertical
Compact The rugged NA2 is indifferent
to weather conditions and
is extremely reliable in the
rough world of the building
site. The pendulum compen-
sator is protected against
knocks and shocks. There is
a highly-effective vibration-
damping mechanism.

Precise The high setting accuracy


ensures that the line of
sight stays put. The attach-
able parallel-plate micro-
meter renders the NA2
ideal for precise fine
levelling.

Reliable, automatic, The instantaneous check


maintenance-free facility with the push-button
control not only makes
work easier; it also
promotes confidence.

Easy handling The convenient, well-


arranged controls are
designed for maximum
convenience. The bilateral,
endless horizontal
drive promotes rapid
fine-pointing.

Quick levelling-up The instrument is quickly


set up with the three rapid-
action footscrews. Their
self-adjusting threads
make subsequent resetting
unnecessary.

Superb telescope Telescope with excellently-


corrected optics for bright,
high-contrast images.
All optical components are
coated on both sides.

Effortless focusing The erect image seen down


the telescope is quickly
and accurately brought into
focus with the convenient
rapid and fine focusing
knob.

Abundant accessories; Additional items such as


many applications the parallel-plate micro-
meter, the laser eyepiece,
or theodolite eyepiece
accessories, offer almost
unlimited possibilities.
LEICA NA2 • NAK2
Proven reliability ensures precise results

Versatile accessories for Robust container for


demonstrable success safe transport

A comprehensive program The NA2 is supplied in a


of accessories enables you foam-padded container
to expand the performance made of high performance
and applications range synthetic material. The
of each instrument. foam padding absorbs all
This way, you can match jolts and shocks. The
your equipment exactly container provides perfect
to requirements. protection for the NA2.

The possibilities are


described in brochure
“Survey accessories”
710 883en.

Technical data

Standard deviation for 1 km double-run


levelling, depending on type of staff and on
procedure up to 0.7 mm
With parallel-plate micrometer 0.3 mm
Telescope erect image
Standard eyepiece 32×
FOK73 eyepiece (optional) 40×
FOK117 (optional) 25×
Clear objective aperture 45 mm
Field of view at 100 m 2.2 m
Shortest focusing distance 1.6 m
Multiplication factor 100
Additive constant 0
Working range of compensator ~30’
Setting accuracy of compensator (stand. dev.) 0.3“
Sensitivity of circular level 8’/2 mm
ISO 9001 / ISO 14001
Glass circle (K version) 400 gon (360°)
Graduation diameter 70 mm
Graduation interval 1 gon (1°) Total Quality Management –
Reading by estimation to 10 mgon (1’) Our commitment to total
customer satisfaction
Water- and dust resistance IP53
Temperature range: Ask your local Leica
Operation –20°C to +50°C (– 4°F to 122°F) Geosystems agent for
Storage –40°C to +70°C (–40°F to 158°F) more information
about our TQM program.
Parallel-plate micrometer Range Interval Estimation
(optional accessory)
GPM3, with glass scale 10 mm 0.1 mm 0.01 mm
GPM6, with metal drum 10 mm 0.2 mm 0.05 mm

Leica Geosystems AG
CH-9435 Heerbrugg
(Switzerland)
Phone +41 71 727 31 31
Illustrations, descriptions, and technical data are not binding and may be changed.
Printed in Switzerland – Copyright Leica Geosystems AG, Heerbrugg, Switzerland, 1999
Fax +41 71 727 46 73
710 837en – V.03 – RDV www.leica-geosystems.com