You are on page 1of 5

FORBES MARSHALL PVT.

LTD
www.forbesmarshall.com

TO: Maria Luisa Sugar

PROJECT: Combined Desuperheating station System

END USER: Maria Luisa Sugar

CUSTOMER'S ENQ. REF: Email Enquiry : Desuperheating station

FROM: Forbes Marshall Pvt Ltd.

FM OFFER REF: FM / 85180016 / PPH R0 Dt.15 May 2018

FORBES CONTACT
Sales Engineer : Pratik Honshetti
PERSON & DETAILS :

With reference to above we are pleased to submit our offer in line with your requirement.

Refer Enclosures for details :


TECHNO-COMMERCIAL BID: Enclosed in same workbook
SIZING SHEET : Enclosed Separately

Hope above is in line with your requirement.

For any further clarifications please feel free to communicate.

Thanking you & assuring our best services always.

Yours faithfully,
Forbes Marshall Pvt. Ltd

Hernando Moreno
International Operations
+573154597558
hmoreno@forbesmarshall.net
Customer : Maria Luisa Sugar
Project : Combined Desuperheating station System
End User : Maria Luisa Sugar
Offer No. / Date : FM / 85180016 / PPH R0 Dt.15 May 2018
Subject : PRDS Station

Techno-Commercial Offer :
End Qnty
Rating / Material Of
Sl. No. Item Description Size Rating Connecti Type Description Make (Nos/Mtr
Sch Const.
on )
Valve Complete with E/P type FM Positioner,
Flanged,
1 Combined PRDS Valve 1 300 Schd. 80 A216 WCB Globe Valve Pneumatic Diaphgram Actuator, Top Mounted FMPL 1
RF
Handwheel, SS316 Tubing, AFR Gauges, etc.
Flanged,
2 Inlet Isolation Valve 1 300 Schd. 80 A216 WCB Gate Valve - FMPL 1
RF
Flanged,
3 Outlet Isolation Valve 1 300 - A216 WCB Gate Valve - FMPL 1
RF
Flanged,
4 Bypass Isolation Valve 1 300 Schd. 80 A216 WCB Globe Valve - FMPL 1
RF
Flanged,
5 Safety Valve 1x2 300 - A216 WCB Full Lift Type Set Pressure - 31.5 barg FMPL 1
RF
FMPL
7 Water line 1 - - Schd. 80 ASTM A106 Gr B Seamless - 1 Lot
Approved
Bypass Isolation Valve for Socket
8 1 800 - ASTM A105 Globe Valve - FMPL 1
Waterline Weld End

Socket
9 Isolation Valves for Water Line 1 800 - ASTM A105 Globe Valve - FMPL 4
Weld End

Socket
10 Strainer for Waterline 1 800 ASTM A105 Y Type - FMPL 1
Weld End

Socket Lift Check


11 Non-return Valve 1 800 - ASTM A105 - FMPL 2
Weld End Type
Valve Complete with E/P type FM Positioner,
Butt
12 Water Control Valve 1 600 Schd. 80 A216 WCB Globe Valve Pneumatic Diaphgram Actuator, Top Mounted FMPL 1
Weld end
Handwheel, SS316 Tubing, AFR Gauges, etc.
FMPL
13 Steamline Piping - Inlet 1 - - Schd. 80 ASTM A106 Seamless - 1 Lot
Approved
FMPL
14 Steamline Piping - Outlet 1 - - Schd. 80 ASTM A106 Seamless - 1 Lot
Approved
Pressure Gauges (Inlet & outlet SS case & SS 1/2 " NPT(M) threads with local mounting, bottom
15 6" Dial - - - - FMPL 2
of steam line) Bourdon connection and 1 no. Syphon
Temperature Gauges (Inlet & SS case & SS Rigid 1/2" NPT bottom connection surface mounting type
16 6" Dial - - - Gas Filled FMPL 2
outlet of steam line) stem with thermowell
Emerson /
- - - - - - Pressure Transmitter & Condensing Pot Honeywell / 1
GIC
Emerson /
- - - - - - RTD with thermowell Honeywell / 1
17 Instrumentation GIC
Emerson /
- - - - - - Field Mounted Temperature Transmitter Honeywell / 1
GIC
- - - - - - Single loop PID Controller w/o Control Panel FMPL 2

Technical Notes :
- End connection of the station will be Flanged RF
- Minimum Instrument air pressure considered as 4 BarG. Kindly make a note of same.
- No Panel has been offered for controllers, please make a note of same
- Refer attached Sizing sheet for detailed of desuperheater and Control Valves
- Complete Station / Equiments will be Hydrotested and all reports shall be provided for Review and Records.
- Note that no special Testing is been considered for any Valves or items mentioned above. In case of any specific testing requirement kindly confirm the same.
- Temp sensor to be located at a distance of 12 mtrs from point of water injection. Hence, the same shall be loose supply. Bypass line to be mounted horizontally.
- Recommended ground clearance of 1000mm for the PRDS station is to be maintained.

Exclusions / Clarifications List :


- All site activities such as erection and commissioning shall be in Purchaser scope. Supervision / guidelines for erection and commissioning will be provided by Forbes Marshall.
- All the necessary welding, pipe insulation , stress analysis , supports for piping , site civil work activities is excluded from FM scope of supply.
- Any other items not specifically mentioned in our offer is excluded from our scope of supply.
Commercial Terms & Conditions :

Price Basis : 25050 CIF Buenaventura , Colombia

Currency : US Dollars

Payment Terms : We propose for following Payment Terms :


- 30% Advance against techno-commerically clear Purchase order
- 70% Upon Material Readiness prior to dispatch against Proforma Invoice

Delivery : 18-20 weeks from the date of receipt of Techno-commercial clear Purchase Order & Receipt of Advance.
Drawings & ITP will be submitted within 2 weeks from date of Purchase Order

Offer Validity : Our offer is valid for 30 days.

Warranty Period : FORBES MARSHALL hereby warrants and guarantees that all GOODS supplied under this PURCHASE ORDER shall conform in
every respect to this PURCHASE ORDER and shall be of new, unused and good materials, design, and of the first class
workmanship, and shall be free from all defects, including, but not limited to, defects of design and workmanship. At
PURCHASER's request, FORBES MARSHALL shall repair and/or replace on a priority basis, free of cost to PURCHASER any part of
GOODS that fails in normal use and service under proper operation, because of defective parts, faulty design or workmanship
within eighteen (12) months from the date of commissioning by PURCHASER or within thirty six (18) months from the date of
dispatch of the GOODS whichever is earlier.

Order is to be placed : Forbes Marshall Private Limited,


Plot No. B-85, Phase II, Chakan Industrial Area,
Village - Savardari - Chakan, Taluka – Khed
District – Pune, PIN 410501, State: Maharashtra

For Forbes Marshall Pvt. Ltd.

Henando Moreno | International Operations


Contact : +57 3154597558
Email : hmoreno@forbesmarshall.net
Ref.: FM/85180016/PPH
CONTROL VALVE Item: 1
SPECIFICATION / CALCULATION SHEET Project Item: 1
Project: - Data Sheet No.: 1
TAG No. PRDS-01 Cust. Ref.: -
Case case I II III pcs 1
Calc. Std.
Revision: 0

Fluid Steam steam


Units Case I Case II Case III Steam Cooling
flow rate lbs/h 662.000 200.000
inlet pressure barG 31.00 31.00 p CW 40.0 barG
Pressure Valve-Outlet barG 9.73 9.73 t CW 105.0 DegC
SERVICE / CONDITIONS

inlet temperature DegC 343.0 250 343.0 250 C.I 19.0 kg/h
density kg/m^3 12.0 12.0 C.II 6.0 kg/h
t2 DegC 250.000 250.000 C.III kg/h
t-sat. p1 DegC 237.600 237.600
t-sat. p2 DegC 183.1 183.1
requ. kv m^3/h 0.780 0.230
capacity travel 65% 64% 20% 18%
pred. sound flash./cavit. 66 <60
velocity valve outlet/pipe m/s 42.2 42.2 12.8 12.8
remark
Pipe Size In 1 inch Shut-off 35 bar
& Schedule Out 1 inch Sched80 Type Pneumatic Act.
LINE

Pipe Line Ins. dB(A) Model SSP3-20R - 1-1,8-O-HV


Single-spring diaphragm actuator
Des. Press/Temp 35barG 372DegC design Std.
Design Outlet Failure Position Air Failure Closed
ACTUATOR
VALVE / BODY / BONNET

Model code F2200 - PR2 painting Std.


Type/ND/rate st.cond.station 1" 300lbs Max Allowable Press. 6 barG
Model description CW inj. through bottom Avail Air Supply Press. 4 barG
top flange extended with cooling fins Area/Springs/Range 320 / 1 / 1-1,8 bar
connection inlet RF SF 1inch 300lbs Actuator Orientation Vertical
connection outlet RF SF 1inch 300lbs Handwheel Type Top mounted
cool/heat/3rd conn.
body material A216WCB
Forbes Marshall, Model 830WP, Weather Proof
Positioner

plug/seat Material SS410-nitr. SS410-nitr. Input Signal 4-20mA, E/P Type


trim tpye 2-st.perforated
1.2 LIN FTC
TRIM

kvs/charact./direct.
fix trim
leak-cl./balanc. IV-metal / -
Air Set

Shavo Make 11-4-SN


seat diameter 19mm
packing/gasket Graphite
spec. applic.
Switch

NA
painting std.
ext. attenuator
extra
Sol. Val.

NA

material certification As per EN10304 3.1


Acces.
TEST

final tests As per FM QAP


NOTES
Ref.: FM/85180016/PPH
CONTROL VALVE Item: 2
SPECIFICATION / CALCULATION SHEET Project Item: 2
Project: - Data Sheet No.: 2
TAG No. TCV-01 Cust. Ref.: -
Case case I II III pcs 1
Calc. Std.
Revision: 0

Fluid Water water


Units Case I Case II Case III Steam Cooling
flow rate kg/h 19.000 6.000
inlet pressure barA 41.00 41.00 p CW barA
Pressure-Drop bar 23.00 24.35 t CW DegC
SERVICE / CONDITIONS

inlet temperature DegC 105.0 105.0 C.I kg/h


density kg/m^3 956.7 956.7 C.II kg/h
Viscosity mPa s 0.269 0.269 C.III kg/h
p-vap barA 1.203 1.203
p-crit barA 220.4 220.4 220.4
requ. kv m^3/h 0.000 0.000
capacity travel 20% 56% 5% 19%
pred. sound flash./cavit. <60 <60
velocity valve outlet/pipe m/s 0.0 0.0 0.0 0.0
remark
Pipe Size In 1 inch Shut-off 50 bar
LINE

& Schedule Out 1 inch Sched80 Type Pneumatic Act.


Pipe Line Ins. dB(A) Model SSP1-20R- 1,8-2,25-O-HV
Single-spring diaphragm actuator
Des. Press/Temp 50barG 120DegC design Std.
Design Outlet Failure Position Air Failure Closed
ACTUATOR
VALVE / BODY / BONNET

Model code F1300-PS1 painting Std.


Type/ND/rate globe-valve 1" 600lbs Max Allowable Press. 6 barG
Model description globe, seat retained Avail Air Supply Press. 4 barG
top flange Standard Area/Springs/Range 320 / 1 / 1,8-2,25 bar
connection inlet Flanged RF Actuator Orientation Vertical
connection outlet Flanged RF Handwheel Type Top mounted
cool/heat/3rd conn. -
body material A216WCB
FM Make, 830WP, E/P Type,4-20mA Signal
Positioner

plug/seat Material SS316 SS316 Weatherproof


trim tpye 1-st.parabolic
TRIM

kvs/charact./direct. 0.02 =% FTO


fix trim
leak-cl./balanc. IV-metal / - Shavo Make, 11-4-SN
Air Set

seat diameter 16mm


packing/gasket PFTE V-Ring+EPDM
spec. applic. NA
Switch

painting
ext. attenuator
extra NA
Sol. Val.

material certification EN 10304 3.1


Acces.
TEST

final tests As per FM QAP