You are on page 1of 5
WARANTY MONTHLY MAINTENANCE of RATNER] ROAD STATION Doc No.: SF-2165 |Rev. No.: 06[Page 1 of 5 [Product Code: si MEI633 Code: NA MEDHA Title: MONTHLY MAINTENANCE SCHEDULE FOR MEI633 ‘Station Nat RATNAGIRI ROAD Division: KUURDA ROAD CECoR) Attended on Date: [¥- O— QOD Service Enginoor: Matgernna Seeha Bloom, SLNo Location Desetlon Aton taken! Range ot opseraton Remarks bain channels Event and Fault (HT Se a ir dca we legs cata downloading shouts ' meant be done Sore te logies & BOaCHR Downcaded alain COV Tamem Ensure the MT PC is abways ON 0d ne sy ps Mr ure the MT PG is tweys ON ar Tine sync tobe check by 2 MT-PC communication links working for Boh comparing MT events og time AAW SNe f time iS ard DL dpay time, Syne. Win DL tine ow online 3 Online VOU simulator should run int heekne Wwe works | ND wereing, Enure DLisinwerkiig = UD Data Looger Ensure DLs nays ON and O conden. ‘ ‘and backed up Re on Data Logger PC Ensure DLPC is always ON Ensure DLPC isin working ue ONS tandon (PC provided) Check the Voltage levels at 2309 PS STATON irmedna tut £ IPS Room jain Input votlage fo FREC modules "SV 10275 Fs _|PSis provided if Medha ut ee Baty bark Votage atfuly STATON fees pate Room Mesnuing cat Barry vote Sheaaonatanaiaudbe SY RTCEN FS. ores 6 tous Gay vt martenance os FSU BC Bee prs Sao Pe Ratnys Baty once 00 to 1220 peak Clean he Dust ers, Exhaust fan Pat a fiers as well s fas Withee Cleaned: 8 ‘Clean the El Equipment's Tobe fre from dust cle ‘Check the communication status ofthe Relevant Communication and Cowmmunicad 8 Equipment Relay 1 Modules anc Ring Modems LEDs shouldbe GlowBin “UR De ee abi Check all Heath Stat LEDsi.e ne 10 ‘Syetor tna iniogon OR, LEDs should be Glow/Blin b \Vbtage nscaon of sysiem ard VOOR Doser VED power LED ration Petes al Ensure any OC FMC falindication or Very all FMC working Ames Buzzer sul not come, conan working » Ensure 0C-DC Moles Fa ‘AlHeatnand power ON EAR UES indication should not Gow. Indications should gow Bea ey om LEDS hey Visually examine al the SACaES © nay the tghiness vo Sema any Yermoes TEA et cmsetetgnenite “Tight Canepa eens acned on, Discomectivpe wsewoge — Fwne Fall ‘4 cece at vogotieinscatens gesretyps uagwene Fane Fal p Clean surface ofthe Earth electrode an 6 Pa ey Sure sbousverestcean gp) Measure the Resistance ofthe RI) Resistance Should be ‘6 Eorh posse, waterin tne Ear anstons Pits to keep low sol resistance jae) 3H Eatin Inseation PO, @ Farting, | heck the SPD devies for any signs of [Chek alndeatenLeD | SPH&s arte, prysical degradation FAL ion ieee nck qlecing,, Chek Lnttirg Arenreomecions! [jstu cwraaawuse | UNS 18 Sopper wre to Rng earth Tghen al Aa Qacked the connections ermnaios ® SM ROOM Ensure VDU PC ON and Check the Indications on OU BOK) emmurication ink is Healthy fr bth PC and Monitor 6 Rand oH Seeing Reference Template number SF-0602 (8) 1/1 Doc No.: SF- 2165 Rev. No.: 06[Page 2 of 5 Product Cod MEI633 SIA Code: ee s* | MEDHA Title: MONTHLY MAINTENANCE SCHEDULE FOR MEI633 SINo Location Description Actiontaken/Rangect observation Remarks Ensue change over VOU! te VDU2 or Commanded VOU shoud tke Change Aontcable for 20 Vee. Vera, Command mede VOU commands andres ofvoU in oyey Q OUALYD ‘shoud werk Normal Faoaion ee ory. caecne 0? Commanded operating Panel — py — a Exe changeover VOU'0 Pane shoul taecormanin and” NP 5 Aplebl for (COP) or Vee Versa. tes hous be mn ncaton eeu ‘mode only. vDv 1, Ensure that hee are no tains rung nya. Recent 2. Ena tat VOU ‘ppieaton made to Tumps itdesbon mode 5 Now close VOU application biles 4 Ghokon Sian men == Fan ype Tempra cick Cleaned. ox B how stt a les and 3 fwese cat remov ol temp fies, vou oth ames tatinceontic vets (tart Rewer’ (Sern | BOXY 7 WOUPC Gated om vBUTTVOURpeS KOK stoddwek VDI Finn selec a fes and oaly afer z Operat\en fess dete oremove alt openng ton les. 7.Once after clearing all temp Checked Efocent fie. Once again re ‘open VOU application and make VDU as command on tmode and do some perations to ancur the Stnetonaiy. Note: Repeat same process feevou see |Voltage Observations at Equipment End : sino. Doseriotion Rango of Votage Levels Observed vokage Remarks 1 Chuckthe Vhage at CUCHA ——2BSLo2BsVOC Lobe cbsened AES 2 Check the Voltage at CIU CH-B 23.5 10 26.5V OC to be observed QGR6Y 3 Check the Voltage at OC CHA 23.5 to 26.5V OC to be observed 94° 53V 4 Chack he Votage at OC CHB 22.510 265V 0C tobe observed SOV. 5 Check the Voltage at OC FMC 23.5 to 24V DC to be observed 24-0\V 6 Check the Votage at OC INT 2310 26.6V 0G tobe observed QA. SEV 7 Check the Votage at PPIVDUCH-A 23.510 28.5V0G tobe observed D4 Hy 5 Checkthe Vekage st PPIVDU CHA _73.5t0.285V0C tobe observed Rasay Check the Vokage at PP IND (FPP A 9 Steck 210 24V DC tobe observed NA Dp 10 Checkthe Vatage at VOU PC 2410 27V DC tobe obsered 5 1av Check he vatage t VOU PC ~2 is Geet eee 2410 27V DC to be observed 95-34V 12 Checkin Votage at MT PC 2419 27V DC tobe observed as-ugy Check the Vakage st VCOR COM, Bal ducer eee aie 230 Z7V DC to be observed 93-FaV |LED Observations in CU; [Doc No.: SF- 2165 Page 3 of 5 ]Product Code: sia @) MEI633, code: | aes NA Title: MONTHLY MAINTENANCE SCHEDULE FOR MEI633 LED Name LED Colour Funetion Observation POWER AMBER iow @ ‘ act GREEN IF INACTIVE Ivahen Gi stoBy AMBER IF INSTAND BY not gens est 2 - comp A. GREEN/NOT — GREEN- COMPA ACTIVE. Activa. | GLOWING) NOTGLOWING- COMPA “NOTIN ACTIVE cows GREEN Nor cREEN-coMP 8. ACTIVE ret GLowmG” —NOTGLOFING-CONPB-NOTINACTIE. Gas LeD Name LED Colour Function Observation POWER AMBER Low Glew ore nee une Blinc’ not GREEN IFINACTWE not ‘leg coves sto ey ‘AMBER IF IVSTAND BY Shem by est 5 = = coMP A GREEN/NOT GREEN COMPA. ACTIVE Active GLOWING) NOTGLOWING- COMPA “NOTIN ACTIVE fe comp 8 GREEN / NOT GREEN-COMP 8 - ACTIVE. Nok | GLOWING NOT GLOWING COMPe-NOTINACTIVE. Glen) LED Namo LED Colour Function Observation POWER AMBER cow Alewi en cre GREEN BLINKING BUanin MGA SSONNG —ROTQOWING. OA shorwacrve, — ACKve. ae GREENNOT GREEN. VIC B -INACTVE wet GLOWING NOT GLOWING: VICB-NOTINACTNE. Ca Leeadog LED Name LED Colour Funetion Observation POWER ‘AMBER cow Glleust oe cre oneeN sunk Bun i. wen “Sonne. Norevowine McA -woriwactwe, — ACHVa- Pin GREENNOT GREEN. VIC B - INACTIVE. bot GLOWING! —NOTGLOWING:VIEB-NETINACTVE. ——_Qlaung, LED Name LED Colour Funetion Observation POWER AMBER cow Glowin: ee a a lowing eR vic Hs COREEN BLINKING Blinking. vicco RECN Low Cleanit com vs GREEN cLow Dalowwi com Hs GREEN BLINKING BGneing| comco, GREEN cLow Glowing cvs LeD Name LED colour Funetion Observation POWER AMBER Low Qlewin, wie vs GREEN cLow Als vic Hs CoREEN BUNKING Rinteins vieco CoREEN cLow Gleest com vs GREEN GLOW Glowing com Hs GREEN BLINKING Doc No.: SF- 2165 |Rev. No.: 06|Page 4 of 5 [Product Code: SIA @) MEI633 ‘Code: NA MEDHA Title: MONTHLY MAINTENANCE SCHEDULE FOR MEI633 comco GREEN cow Gloutng LED Observations in OC: LED Name LEO Colour Function Observation POWER ANIBER Low (eANE EP WP RX GREEN BLINKING Blind ‘omBA. WEP TX AMBER BLINKING. Blink. ore GREEN BLINKING Biineins com ax GREEN LINKING Blaning com 1x UBER BLINKING BWVinkin, LED Name LED Coloue Funetion Observation POWER AMBER iow Glowing WFP RX GREEN BLINKING. BVianking orce-8 WrP TX AMBER BLINKING BUneing ove GREEN BUNKING ‘Bineies comex GREEN BLINKING. Bunga com Tx AMBER BLINKING Bonsing LED Name LEO Colour Function Observation POWER AER iow Qlecate aes vsts GREEN cow Glows ae =e on eS leine cutore GREEN Low Glewing LED Namo LEO Colour Function Obsonvation POWER AMBER cLow Glresting- vsts GREEN cLow Glowing, Hsts GREEN BLINKING Blinn. CUTOFF GREEN GLOW QAhew? LED Name LEO Colour Function Observation POWER AMBER Low Glewin; voor AMBER cLow Glewing SISA GREEN BLINKING Bentelng. one stsB GREEN BLINKING Bintes: opt GREEN OUTPUT CARO 1 AVAILABLE Dyin. ope GREEN OUTPUT CARO 2 AVAILABLE Avoilabte ors GREEN Mf OUTPUT CARD 3 AVAILABLE Available ‘voor POWER ORANGE cLow Gleusng LED Onsorvations in PP: LED Name LED Colour Funetion Observation POWER UBER cLow PPCC-A ove GREEN BLINKING i cs AMBER IF PPCC-A OBJECT ENABLE. oo 4 com ex oneen unas Ca ain) com Tx AMBER BLINKING PPcc-s LED Name LED Colour Function ‘Observation Doc No.: SF-2165 [Rev. No.: 06|Page 5 of 5 ProduciGose SA wD cess Eom @) Title: MONTHLY MAINTENANCE SCHEDULE FOR MEI633 POWER ee oe ‘COM RK com Tx LED Name POWER vsts HSTS. CUT. OFF LED Name PPVH-A POWER vsts HsTS cut. OFF PVE cont BER, he Medha Representative AMBER GREEN AMBER GREEN AMBER LED Colour AMBER GREEN GREEN GREEN LED Colour AMBER GREEN GREEN GREEN Metgeniks Sexhar Bloor c.ow BLINKING IF PPCC-B OBJECT ENABLE ‘BLINKING Teh DOA aUNKNG TE RE Funetion Observation iow aa AA BLINKING more Low 7 DU Futon ear iow ae cow ofA py At ee sot hKeroe 18.13.202/ Railway Representative S&T"

You might also like