You are on page 1of 22

Bild

H 9.4 cm x W 27.53 cm

The new Instrument Family


Dräger Pac 1000, Dräger Pac 3000, Dräger Pac 5000, Dräger Pac 7000

Dräger Pac Instruments


Lübeck, 05/2008, Ulf Ostermann
Agenda
Dräger Pac Instruments

1 THE NEW INSTRUMENT FAMILY


2 AROUND THE INSTRUMENT
3 WHAT IS WHAT
4 OPERATING ELEMENTS
5 ALARMS
6 SOFTWARE FUNKTIONS
7 APPROVALS
8 APPLICATIONS
9 ACCESSORIES

2|1 The new Pac Instruments | UO/BP | 02/04/2008


The new instrument Family
Different Instrument Versions

These monitors are single-gas measuring and alarm devices


They are intended for use in detecting and warning users of hazardous levels of the
following gases in ambient air:
Oxygen (O2) Chlor (Cl2)
Carbon monoxide (CO) Carbon dioxide (CO2)
Hydrogen sulfide (H2S) Phosphine (PH3)
Ammonia (NH3) sulphur dioxide (SO 2)
Hydrogen cyanide (HCN) Nitrogen dioxide (NO2)
Organic vapours (OV / OV-A) Hydrogen sulfide LC (H2S – LC)

3|1 The new Pac Instruments | UO/BP | 02/04/2008


The new instrument Family
Different Instrument Versions

Dräger Pac 1000 (CO, H2S, O2)


• maintenance-free instrument for 100 days with status display.
Dräger Pac 3000 (CO, H2S, O2)
• maintenance-free instrument with status display and adjustable operating timer
from 1 day to 2 years.
Dräger Pac 5000 (CO, H2S, O2)
• maintenance-free instrument with concentration display, adjustable operating
timer from 1 day to 2 years, and event logger.
Dräger Pac 7000 (more sensors)
• Instrument with unlimited lifetime and sensor exchange, concentration display,
adjustable operating timer from 1 day to 2 years, and data logger.

4|1 The new Pac Instruments | UO/BP | 02/04/2008


The new Instrument Family
Different Instrument Versions

Dräger Pac 1000 Dräger Pac 3000 Dräger Pac 7000


Permanent sensors for 100 additional to Dräger additional to Dräger
days
Pac 1000 Pac 5000
H2S, CO, O2
Permanent sensors for 2 Unlimited lifetime
A 1 & A 2 alarms years More and changeable
Visual, audible, and vibrating Adjustable operating timer sensors
alarm
Changeable battery Four digit concentration
IR interface display
Bump test mode TWA alarm
Status display STEL alarm
Dräger Pac 5000
additional to Dräger Peak value

Pac 3000 Password protected menu


for calibration
Concentration display
Data logger
Event logger

5|1 The new Pac Instruments | UO/BP | 02/04/2008


Around the Instrument
Main Features

Large and language-free Display


Personal monitoring orientated size and weight
Tight wearing using an alligator clip
Ease of use
Low cost of ownership

6|1 The new Pac Instruments | UO/BP | 02/04/2008


Around the Instrument
Main Features

The instrument is maintenance-free and manly service-free

Two button intuitive operation Latching buttons

Rotate-able alligator clip Leather carrying case

Connecting Cradle Bump Test Station

Individual configuration Configuration / calibration software:

E-Cal Module - Pac Vision

- CC-Vision

- GasVision

- CC-Vision E-Cal

7|1 The new Pac Instruments | UO/BP | 02/04/2008


Around the Instrument
Rugged Enclosure

Polyamide housing resistant to corrosive chemicals


RFI shielding per IEC specification
Sealed against water and dust ingress IP 65
Covered with rubber

8|1 The new Pac Instruments | UO/BP | 02/04/2008


Around the Instrument
Dräger Sensors XXS

New DrägerSensor technology

The new Dräger XXS sensors react rapidly due to fast electro-chemical reaction
times and a very short diffusion path.

9|1 The new Pac Instruments | UO/BP | 02/04/2008


What is What

Sensor Opening With


Dust- And Waterfilter

Visual Alarm
Audible Alarm

Integral Rubber
Over-mold
LCD Display

+ Button: Menu / OK Button


Bump Test Mode

Type Of Gas To Be
Measured Visual Alarm

10 | 1 The new Pac Instruments | UO/BP | 02/04/2008


What is What

D-Ring

Serial # / Integral Rubber


Part # Label Over-mold

Rotatable Grip Clip IR Interface

Lithium Battery
Compartment

Approval Label

11 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Operating Elements

Switch on: press “OK” key

Remaining time: Press “+” key for 1 second, while


instrument is switched off

Acknowledgement of alarms: Press “OK” key

Switch off: Press “OK” and ”+” key together

12 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Operating Elements

Indication of TWA, STEL, Peak Value, and number


of STEL periods:
Ø Press “OK” key successively for each value
(additional for Dräger Pac 7000)

Password protected menu:


Ø Press “+” key 3 times within 3 seconds
(additional for Dräger Pac 7000)

13 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Alarms

Alarms pointed towards user


eyes and ears

Loud audible alarm


>90 dB (A) at a distance of 30 cm (1 ft)

Intigrated vibrating alarm

Bright visual alarm


2 high-intensity LED’s visible: 180°

14 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Alarms
Interface
Vibrating alarm
Unique alarm cadence using a two-tone alarm
A1: single beep (low level alarm)

A2: double beep (high level alarm)

ERROR: triple beep (instrument fault)

LCD characters
A1 & A2 in display
Error icon
Notice icon
Battery icon
Additional for Dräger Pac 7000:
Peak Value
TWA
STEL

15 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Software Functions
Overview
For calibration and individual configuration
the instrument will be connected to a PC
with installed Vision software

Change alarm set points: “A1 & A2”


Adjust operating timer
Adjust bump test interval
Adjust manual or automatic bump test
“Switch Off” disable
Security beep
Measuring units: “ppm or mg/m³”
Calibrate sensor
Readout event logger
Dräger 7000:
Readout data logger
Adjust TWA and STEL alarms

16 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Software Functions
Dräger Pac 3000 - 7000

Adjustable operating time from 1 day to 2 years

Calibration due date

Inspection due date

Out of order date

17 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Software Functions
Dräger Pac 5000 and Dräger Pac 7000

Dräger Pac 5000:


The event logger stores 60 events.
If event no. 61 occurs the logger overwrites the oldest stored event.

Dräger Pac 7000:


Additional the data logger stores the peak concentration measured during a variable
adjustable interval. The data logger runs about 5 days in a 1 minute interval. If the
memory is filled the data logger overwrites the oldest stored data.

For download of the stored data with date and time a PC and the installed software
Pac Vision or CC Vision, will be used.

18 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Approvals

The units meet the intrinsic safety requirements for use in hazardous areas for ATEX, UL and CSA

Ø UL Class I, II Div I, Group A, B, C, D, E, F, G,


Temp Code T4
–30°C = Ta = +55°C (–22°F = Ta = +131°F)

Ø cUL Class I, II Div I, Group A, B, C, D, E, F, G,


Temp Code T4
–30°C = Ta = +55°C (–22°F = Ta = +131°F)

Ø CE0158 (89/336/EEC, 94/9/EC)

Ø DEMKO 04 ATEX
I/II M 1/1 G EEx ia I/IIC T4,
–30°C = Ta = +55°C (–22°F = Ta = +131°F)

Ø IEC Ex

Ø Baumusterprüfbescheinigung
PFG 07 G003

19 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Applications

Designed for typical industrial applications


Only provides basic monitoring functions,
especially for personal monitoring.
Ideal for:
Shut down / turn-around operations
Steel / Metal Industry
Petro-Chemical Industry
Oil & Gas Industry
Mining

20 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Accessories

Connecting cradle complete with USB cable and Pac Vision software

Lithium battery
Dust- and water filter

Leather carrying case

Bump Test Station, complete with test gas cylinder 58 L

E-Cal instrument module for connection to a E-Cal Master Station or to


Module Adapter

21 | 1 The new Pac Instruments | UO/BP | 02/04/2008


Thank you for
your attention.

22 | 1 The new Pac Instruments | UO/BP | 02/04/2008