STEEL STRUCTURE LIFT CORE AT

STAIR BLOCK AT BIDYUT BHABAN,


1 ABDUL GONI ROAD, DHAKA, UNDER
TENDER ID 431809 .

OWNERS NAME

NOTES ON STRUCTURAL STEEL :

1. ALL STEEL SECTIONS (HOT ROLLED) SHOULD BE OF GRADE 40 ksi. ARCHITECT NAME,SIGN

2. FOR THE VERTICAL AND HORIZONTAL BRACING ONLY THE HOT ROLLED STEEL ANGLE
SECTION TO BE USED.

3. ALL STEEL STRUCTURAL CONNECTION BOLTS OR ANCHOR BOLTS SHOULD BE OF RADE 8.8.

4. THE CONTRACTOR IS REQUIRED TO SUBMIT A COMPLETE FERICATION DRAWING (AS SITE


CONDITION) FOR APPROVAL FROM THE CONSULTANT BEFORE INSTALLATION.

5. FOR WELDED CONNECTIONS MINIMUM 6 mm THICK FILLET/FUSHION FILLET WELD IS TO BE


USED. THE MINIMUM LENGTH OF THE WELD WITH ANY MEMBER ON EACH SIDE SHOULD NOT BE
LESS THEN 4" (100 mm) STRUCTURAL ENGINEER

SHEIKH MIZANUR RAHMAN


MIEB, RAJUK REGISTERED
6. THE THICKNESS OF GUSSET PLATES, PACKING PLATE OR SPLICING PLATE SHOULD NOT BE
LESS THEN 9 mm.

DRAWING TITLE:
FRAMING PLAN AND
COLUMN LAYOUT PLAN