TECHNICAL COMMUNICATION No. TC1212 Ed.

02

OmniPCX Enterprise Nb of pages : 10 Date : 10 August 2010

URGENT

NOT URGENT TEMPORARY PERMANENT

SUBJECT: CS-2 BOARD INTRODUCTION

CONTENTS

1. OVERVIEW...................................................................................3

2. CONSTRAINTS & RECOMMENDATIONS.......................................3

3. MANAGEMENT OF BIOS SETTINGS..............................................5

4. TERMINAL SETTING ...................................................................10

1
2
OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

1. OVERVIEW
This new Common Hardware CPU board is handled by OmniPCX Enterprise R9.0 since the patch
H1.301.31.b and by the version 13.6 of Actis.
References:

Communication Server processing unit board equipped (CS-2) 3BA00727AA


Passive Communication Server processing unit board equipped / CS-2 (PCS) 3BA00729AA
CPU CS-2 board (without hard drive) 3EH73086AB

This board covers both Call Server and PCS functions.


Regarding the Call Server function, the same Actis rules as the ones for the previous CS board apply
in OmniPCX Enterprise R9.0. Only in OmniPCX Enterprise R9.1, new Actis rules are applied and
covered by the documentation of the Actis release which is released with OmniPCX Enterprise R9.1.
Regarding PCS function, the previous limitation which makes compulsory the use of an Appliance
Server as PCS in a small branch office if the node contains globally more than 5000 users is
removed thanks to this new board.
The CS-2 board brings the Ethernet Redundancy as a new feature, respect to the previous CS board.
This new function brings also the load balancing.
Compatibilities
• OXE R9.0 version H1.301.31.b
• Actis version 13.6
• BIOS version AMI 9.0
• PC Installer version 2.24

2. CONSTRAINTS & RECOMMENDATIONS


To access the BIOS interface setup of the board, use Ctrl-B or Ctrl-S when prompted during the
startup of the board.
Note
Ctrl-I has not to be used, unless requested by Alcatel-Lucent support.
If the Ethernet duplication is not activated, the second Ethernet interface must not be used.
To load a version in CS-2 boards, the PC Installer HAS to be used in version 2.24 minimum.
While performing a complete installation, the Type of Call Server parameter HAS to be set to
CS-2 and no more to the "Alize" value, used for the previous CS board.

Ed. 02 / 10 August 2010 3 TC1212


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

TC1212 4 Ed. 02 / 10 August 2010


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

3. MANAGEMENT OF BIOS SETTINGS


• Check that PXE is enable:

Ed. 02 / 10 August 2010 5 TC1212


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

• Serial port redirection management:

TC1212 6 Ed. 02 / 10 August 2010


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

Ed. 02 / 10 August 2010 7 TC1212


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

• Emulation terminal type used:

• Boot order settings managed with 2 priority options:

TC1212 8 Ed. 02 / 10 August 2010


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

• Save modifications and Exit :

Note
To boot on Ethernet, you have to select "IBA GE Slot 0200 v126" on tab "Save & Exit" in order to load
the OXE software on the server with PC Installer.

Ed. 02 / 10 August 2010 9 TC1212


OmniPCX Enterprise
CS-2 BOARD INTRODUCTION

4. TERMINAL SETTING
By default, CS2 console Output is managed as ANSI type. So, you have to use the same on your
terminal session.
For example for Hyperterminal

Do a new connection: Click on Configure:

On tab settings use emulation type ANSIW and click on OK:

TC1212 10 Ed. 02 / 10 August 2010