N.S.L N.S.

(TO BE DECIDED AS PER (TO BE DECIDED AS PER

Y
Y
SITE/SERVICES REQUIREMENTS SITE/SERVICES REQUIREMENTS
OR PROPOSED BUILDING STRUCTURE) OR PROPOSED BUILDING STRUCTURE) 1800 1800

1000 1000 1000

CAPPING BEAM

750
750
(1000x750)

CAPPING BEAM
(1000x750)

A A D D Ø 1000 R.C.C Ø 1000 R.C.C PROPERTY LINE

#3@100
(SPIRAL)
8-#11 PRIMARY PILE (P-1) SECONDARY PILE (P-2)

#3@100 (TIES)
8-#11 (TYP.) (TYP.)

7500
7500
TYPICAL PART PLAN FOR SECANT CANTILEVER PILES
SCALE 1:40

LAP
LAP
1000 1000 1000
6-#6

8-#11 8-#11

#4@100(TIES)
#3@100 #3@100
SPIRAL
#3@150

2000
2000
#4@75(SPIRAL)
3-#6 3-#6

750
BOTTOM OF RAFT FOUNDATION BOTTOM OF RAFT FOUNDATION

Ø 1000 Ø 1000

10-#11 12-#11 SECTION A-A SECTION D-D


SCALE 1:30 SCALE 1:30
6-#6

1000 1000
10-#11
12-#11

PILE LENGTH (REFER TABLE-1)

PILE LENGTH (REFER TABLE-1)


#4@100
B B E E #4@75 CAPPING BEAM REINF.
SPIRAL SCALE 1:16

7000
7000
SECTION B-B
SCALE 1:30 SECTION E-E
SCALE 1:30

1000 1000

8-#11 8-#11

#3@150 #3@150
SPIRAL

8-#11 8-#11

SECTION C-C SECTION F-F


SCALE 1:30 SCALE 1:30
C C F F NOTES
1. FOR NOTES REFER DRAWING NO. 4125/035/C/G02 (SHEET 1 OF 4).
2. FOR PILE LENGTHS TABLE REFER DRAWING No.
PCT-2A PCT-2 4125/035/C/G02.

#3@150(TIES)
#3@150(SPIRAL)
0 1 2 3 4 5 METERS

SECTIONAL ELEVATION PILE (PCT-2A) SECTIONAL ELEVATION PILE (PCT-2) SHEET 2 OF 4


CLIENT CONSULTANT 04 DRAWN G.SARWAR PROJECT SCALE
PILE RETENTION SYSTEM
NATIONAL ENGINEERING SERVICES 03 SUBMITTED CONSTRUCTION OF ADDITIONAL BLOCK SECANT CANTILEVER PILES
PAKISTAN ENGINEERING COUNCIL PAKISTAN (PVT.) LTD. 02 RECOMMENDED AT PEC HEADQUATER, SECTOR G-5/2, (CONCRETE OUTLINE & REINFORCEMENT)
01 CHD./VER. ISLAMABAD DATE DRAWING No. REV.
HEAD OFFICE:- NESPAK HOUSE, I-C, BLOCK-N,
MODEL TOWN EXTENSION, LAHORE, PAKISTAN. REV. DATE DESCRIPTION APPROVED APPROVED MARCH, 2021 4125/035/C/G02 0