INTEGRATED MANAGEMENT SYSTEM Tgl Terbit : 10 Juli 2020
LAPORAN KONDISI PERALATAN ALAT PEMADAM KEBAKARAN Revisi : 01
BULAN : JUNI 2021 Halaman :1
NO NAMA PERALATAN SPESIFIKASI JUMLAH SATUAN DOKUMENTASI FREKUENSI PEMELIHARAAN
Cap. 25 GPM, Head 110 M
1 JOCKEY PUMP Grundfos Vertical Multistage Pump 1 Unit WEEKLY TEST
Model : CR 5-22
Material : Cast Iron Case, SS Impeller
and SS Shaff
Power : 5,5HP /3Ph/50Hz/380V/
2900 RPM
C/w : Jocky Pump Controller (NFPA 20)
Cap. 750 GPM, Head 10 BAR
2 ELECTRIC FIRE Fairbanks Nijhuis Horisontal Split Case Pump WEEKLY TEST
PUMP CONTROLLER Model : 5”-1822C,2950 RPM
Suction Sise : 6", Discharge Sise :5"
Pump BHP : 125 HP 1 Unit
Material : Cast Iron Case, Bronze
Impeller, Steel AISI C1045 Shaft
Power : 125HP/380V/3Ph/50Hz/2950RPM
C/w : Electric Fire Pump Controller (NFPA 20)
MATERIAL : ALUMINIUM
16 NOZZLE HYDRANT NOZZLE HAND LEVER 2,5″ 4 Buah MONTHLY INSPECTION
NOZZLE HAND LEVER 1,5″ 1 Buah
Buah
Buah
Arief F Putera
PT INDONESIA POWER BALI POWER GENERATION UNIT No. Form : BLI.14.04.31
INTEGRATED MANAGEMENT SYSTEM Tgl Terbit : 10 Juli 2020
LAPORAN KONDISI ALAT PEMADAM API RINGAN ( APAR ) DAN HYDRANT Revisi : 01
BULAN : APRIL 2021 Halaman : 1
NO KONDISI APAR JUMLAH SATUAN KETERANGAN DIAGRAM PROSENTASE KONDISI APAR YANG STANDBY DAN NOT STANDBAY
1 BAIK ( STANDBY ) 16 TABUNG Siap pakai, terpasang DI BALI PGU
Untuk sementara ditaruh di Ruang Baik 30% 16
2 Spare ( baik ) 0 TABUNG
Peralatan K3 dan Lingkungan Rusak 7
3 TIDAK BAIK ( RUSAK ) 0 TABUNG Berkarat dan tidak layak pakai 23 Baik
4 KOSONG 7 TABUNG Proses refill selesai Baik 69.57% 70%
Rusak
5 U/. Toss di Klungkung TABUNG Rusak 30.43%
TOTAL APAR 23 TABUNG
BAIK JUMLAH
NO KONDISI HYDRANT ( STANDBY ) TIDAK BAIK TOTAL KETERANGAN DIAGRAM PROSENTASE KONDISI VALVE HYDRANT
0%
Baiik 53 0%
Rusak 0 Baik 19
53 Rusak 0
Baik 100% 19 Baik
Baik
Rusak 0% Baik 100%
Rusak
Rusak Rusak 0%
100%
100%
Baik 0% 46
Rusak 0
46
Baik 100%
Rusak 0% Baik
Rusak
100%
PT INDONESIA POWER No. Form : BLI.14.04.31
PT INDONESIA POWER MPP NABIRE Tgl Terbit : 10 Juli 2020
INTEGRATED MANAGEMNT SYSTEM Revisi : 01
LAPORAN KONDISI FIRE PUMP Halaman : 1
BULAN : JUNI 2021