Professional Documents
Culture Documents
Specifications
ECO Model HWP 36Y HWP 48Y HWP 59Y HWP 79Y HWP 98Y
Nominal Cooling Capacity * kW 1
3.5 4.4 5.9 8.1 9.9
Net Cooling Capacity (MEPS) kW 3.4 4.3 5.7 7.9 9.8
EER / AEER (cooling) 3.69 / 3.67 3.79 / 3.77 3.75 / 3.73 3.94 / 3.92 3.95 / 3.94
Heating Capacity *2 kW 3.7 4.6 5.4 8.9 11.3
COP / ACOP (heating) 4.08 / 4.04 4.17 / 4.14 3.87 / 3.85 4.36 / 4.35 4.35 / 4.34
Electric Heat Option HWP-CE kW 2 2 3 4 4
Air Flow *3 l/s 190 230 320 500 560
Power Source *4 1 phase 230V a.c. 50 Hz
HWPSR version
Running Current * 1 A 4.0 5.0 6.8 8.7 11.0
Max. Running Current A 6.1 7.6 10.7 12.8 18.1
HWPSCE version
Running Current *9 A 9.1 9.2 14.1 18.3 18.7
Max. Running Current A 10.0 10.0 14.3 20.3 19.5
Refrigerant R410A
Nominal Water Flow *5 l/s 0.22 0.28 0.34 0.50 0.61
Minimum Water Flow * l/s 6
0.06 0.07 0.09 0.14 0.18
Water Coil Pressure Drop* kPa (psi) 27.6 (4)
7
27.6 (4) 41 (6) 70 (10) 41 (6)
Unit Controller UC8
Materials and specifications are subject to change without notice due to the manufacturer’s ongoing research and development programme.
Page 26 of 28
Water Cooled air conditioners
Specifications
ECO Model HWP 118Y HWP 142Y HWP 172Y HWP 192Y HWP 255Y HWP 275Y
Nominal Cooling Capacity * kW 1
12.2 14.7 18.5 21.2 25.5 27.5
Net Cooling Capacity (MEPS) kW 11.9 14.1 17.4 19.9 24.8 26.7
EER / AEER (cooling) *8 4.17 / 4.16 4.45 / 4.44 4.35 / 4.32 4.44 / 4.42 4.65 / 4.63 4.48 / 4.47
Heating Capacity *2 kW 11.6 14.5 16.7 18.6 23.0 24.6
COP / ACOP (rev. cycle heating) 3.92 / 3.91 4.36 / 4.35 4.28 / 4.25 4.32 / 4.30 4.59 / 4.58 4.37 / 4.36
Electric Heat Option HWPSCE kW 6 6 9 9 12 12
Air Flow *3 l/s 620 775 1015 1160 1220 1400
Power Source *4 3 phase 400V
HWPSR version
Running Current * 1 A 4.9 / 4.1 / 4.1 6.0 / 4.6 / 4.6 7.6 / 6 / 6 10 / 7 / 7 11 / 8 / 8 13 / 9.5 / 9.5
Max. Running Current A 9.6 / 6.3 / 6.3 10.6 / 7.2 / 7.2 13.7 / 8.8 / 8.8 14.3 / 10.8 / 10.8 16.5 / 12 / 12 15.5 / 13 / 13
HWPSCE version
Running Current *9 A 1.4 / 13 / 13 1.9 / 13 / 13 15.3 / 13 / 13 16.9 / 13 / 13 21 / 17.5 / 17.5 22 / 17.5 / 17.5
Max. Running Current A 9.6 / 13 / 13 10.6 / 13 / 13 18.2 / 13 /13 18.2 / 13 / 13 22 / 17.5 / 17.5 23 / 17.5 / 17.5
Refrigerant R410A
Nominal Water Flow *5 l/s 0.75 0.88 1.06 1.26 1.53 1.63
Minimum Water Flow * l/s 6
0.21 0.24 0.30 0.35 0.43 0.46
Water Coil Pressure Drop* kPa (psi) 55 (8)
7
69 (10) 83 (12) 34 (5) 48 (7) 55 (8)
Unit Controller UC8
Materials and specifications are subject to change without notice due to the manufacturer’s ongoing research and development programme.
Page 27 of 28