(Ideal Condition, Cooling Tower Running Only, @ T_ambient air = 33 Deg C, RH = 82%)
Line No 1 2 6 7 8 9
Flow rate (m3/h) 111 12 270 270 25 245
Op. Temperature (°C) 38 34 34 34 34 34
Op. Pressure (barg) 3 Atm Atm 7.2 1.5)* 7.2
Note : )* reducing through pressure reducing valve
(Worst Case Condition, Cooling Tower + Water Chiller Running, @T_ambient air = 39 Deg C, RH = 99%)
Line No 1 2 3 4 5 6
Flow rate (m3/h) 245 245 270 270 270 270
Op. Temperature (°C) 40 39.2 39.2 39.2 34 34
Op. Pressure (barg) 3 Atm Atm 3 2.5 Atm
Note : )* reducing through pressure reducing valve
Note : )* using pressure regulatng valve exactly before battery limit of building
Line Description :
1. Return from Acid Plant Building to Cooling Tower
2. Cooling Tower to Cooling Water Buffer Tank
3. Cooling Water Buffer Tank (Hot Side) to Chilled Water Feed Pump
4. Chilled Water Feed Pump to Water Chiller
5. Water Chiller to Cooling Water Buffer Tank (Cold Side)
6. Cooling Water Buffer Tank (Cold Side) to Cooling Water Transfer Pump
7. Cooling Water Transfer Pump to Acid Plant Building
8. Recirculation to Cooling Water Buffer Tank (Hot Side)
Line No 1 2 3 4 5 6
Flow rate (Nm3/h) 45 45 23 10 23 10
Op. Temperature (°C) 35 35 35 35 35 35
Op. Pressure (barg) 9.5 9.1 9 8 9 8
Line Description :
1. Discharge line of Compressor to pre-filter
2. Air Dyer to After Filter
3. Air Buffer Tank 1 to Pressure Regulator
4. Pressure Regulator to Utility Building & Acid Plant Building (for instrument air)
5. Air Buffer Tank 2 to Pressure Regulator
6. Pressure Regulator to Utility Building & Acid Plant Building (for service air)
Line Description :
1. Make up water to Feed Water Tank
2. Feed Water tank to Boiler Feed Water Pump
3. Boiler Feed Water Pump to Boiler
4. Boiler to Pressure Regulator
5. Pressure Regulator to Acid Plant Building
6. Steam condensate from process to KO Drum Tank
7. KO Drum Tank to Feed Water Tank
Line No 1 2 3 4 5 6
Flow rate (Nm3/h)
Op. Temperature (°C)
Op. Pressure (barg)
Line Description :
g C, RH = 99%)
7 8 9
270 25 245
34 34 34
7.2 1.5)* 3)*
7 8 9
171 kg/h 171 kg/h 2003 kg/h
Ambient Ambient 214
1 1 19.5
250 kg/h 250 kg/h 2400 kg/h
Ambient Ambient 222
3 3 23
Cooling Water System
Example
Steam System
Boiler Feed Water
Feed Water Tank Fire Tube Boiler
Pump
SCS-TK-011 SCS-P-011/012 SCS-B-011
F = 2.5 m3/h @
V = 4 m3 Cap. 2400 kg/h
2x100% duty
Atm 20 19.5
3 25 25
up to 88)* up to 88)* 217
To be defined To be defined MFT STD
MFT STD MFT STD MFT STD
Atmospheric Tank, with Vertical Multi Stage Type Pressure Vessel
insulation
Pressure Tank Cooling Water Water Chiller Feed Water Chiller
Transfer Pump Pump
COS-TK-021 COS-P-011/012/013 COS-P-021 COS-WC-011/012
F = 135 m3/h F = 270 m3/h Cooling Cap. =
V = 1 m3 @3x50% duty @1x100% duty 1680 kW (total)
7.3 7.2 3 2.5
10.95 10.8 4.5 3.75
34 34 34 34
51 51 51 40/33
MFT STD MFT STD MFT STD MFT STD
diaphragm/bladder Air Cooled Type
tank Centrifugal Pump Type Centrifugal Pump Type
SCS-TK-031 SCS-PCV-011
output @ 17 Barg
V=0.5 m3 @ 2000 kg/h
17 17
19 25
up to 88)* 207
To be defined MFT STD
MFT STD MFT STD
Atmospheric Tank Diaphragm/Spring
with insulation adjusted