SHEET FOR VALVE SIZING CALCULATIONS.

CONDITION - FLOW MEDIUM LIQUID / FLOW IS BY WEIGHT.

INPUT DATA

1 SERVICE FLUID LIQUID

2 FLOW RATE (1000 Kg/hr) MAX / NOR / MIN (w) 5 7 10


3 INLET PRESSURE (P1) BARA 5
4 OUTLET PRESSURE (P2) BARA 4
5 DELTA P - SIZING (BAR) 1
6 FLUID TEMPERATURE (T) 0K 320
7 SPECIFIC GRAVITY (G) 1.1

Since DELTA P < P1/2. Therefore, flow is subcritical.

Formula for Cv Calculation ( Flow By Weight )

Cv = 1.16w / S Gr x DELTA P

Cv(max) = 5.8 Cv(Nor) = 8.2 Cv(Min) = 11.7


FROM mm OF wc

CONVERSIONS :

1 TO CONVERT PRESSURE.
Since DELTA P < P1/2. Therefore, flow is subcritical.
Since DELTA P > P1/2. Therefore, flow is critical. FROM Kg/Cm2 (g)

FROM BAR

2 TO CONVERT TEMPERATUR

FROM 0 C

Where Gr = Specific Gravity of the fluid at flowing


temperature.

Gr = G x ( 288 / T ) = 0.990
0.000 bar

TO CONVERT PRESSURE.
INPUT VALUE IN BARA
1.0130

1.0130

TO CONVERT TEMPERATURE.
INPUT VALUE IN 0K.

273
SHEET FOR VALVE SIZING CALCULATIONS.

CONDITION - FLOW MEDIUM LIQUID / VOLUMETRIC FLOW.

INPUT DATA

1 SERVICE FLUID LIQUID

2 FLOW RATE (m3/hr) MAX / NOR / MIN (Q)

3 INLET PRESSURE (P1) BARA

4 OUTLET PRESSURE (P2) BARA

5 DELTA P - SIZING (BAR) 0

6 FLUID TEMPERATURE (T) 0K

7 SPECIFIC GRAVITY (G)

Since DELTA P > P1/2. Therefore, flow is critical.

Formula for Cv Calculation ( Flow By VOLUME )

Cv = 1.16QS Gr / DELTA P

Cv(max) = #DIV/0! Cv(Nor) = #DIV/0! Cv(Min) = #DIV/0!


Since DELTA P < P1/2. Therefore, flow is subcritical.

Since DELTA P > P1/2. Therefore, flow is critical.

Where Gr = Specific Gravity of the fluid at


flowing temperature.

Gr = G x ( 288 / T ) = #DIV/0!
FROM mm OF wc 0.000 bar

CONVERSIONS :

1 TO CONVERT PRESSURE.

INPUT VALUE IN BARA

FROM Kg/Cm2 (g) 4 4.9358

FROM BAR 1.013

2 TO CONVERT TEMPERATURE.

INPUT VALUE IN 0K.

FROM 0 C 273
SHEET FOR VALVE SIZING CALCULATIONS.

CONDITION - FLOW MEDIUM GAS / FLOW IS BY WEIGHT.

INPUT DATA

1 SERVICE FLUID GAS

2 FLOW RATE (1000 Kg/hr) MAX / NOR / MIN (w)


3 INLET PRESSURE (P1) BARA

4 OUTLET PRESSURE (P2) BARA


5 DELTA P - SIZING (BAR) 0
6 FLUID TEMPERATURE (T) 0K
7 SPECIFIC GRAVITY (G)

8 COMPRESSABILITY FACTOR (Z)

Since DELTA P > P1/2. Therefore, flow is critical.

Formula for Cv Calculation ( Flow By Weight )

Cv = 47.2 w S Z / S (DELTA P x (P1 + P2) Gr)

Cv(max) = #DIV/0! Cv(Nor) = #DIV/0! Cv(Min) = #DIV/0!


GAS

Since DELTA P < P1/2. Therefore, flow is subcritical.


Since DELTA P > P1/2. Therefore, flow is critical.

Where Gr = Specific Gravity of the


fluid at flowing temperature.

Gr = G x ( 288 / T ) = #DIV/0!
FROM mm OF wc 0.000

CONVERSIONS :

1 TO CONVERT PRESSURE.
subcritical. INPUT VALUE IN BARA
FROM Kg/Cm2 (g) 1.0130

FROM BAR 1.0130

2 TO CONVERT TEMPERATURE.
INPUT VALUE IN 0K.

FROM 0 C 273
bar
SHEET FOR VALVE SIZING CALCULATIONS.

CONDITION - FLOW MEDIUM GAS / FLOW IS BY VOLUME.

INPUT DATA

1 SERVICE FLUID GAS

2 FLOW RATE (m3/hr) MAX / NOR / MIN (Q) 10800 3600 4140
3 INLET PRESSURE (P1) BARA 0.000 0.000 0.000
4 OUTLET PRESSURE (P2) BARA 0.000 0.000 0.000
5 DELTA P - SIZING 0.001 0.001 0.002
6 FLUID TEMPERATURE (T) 0K 318
7 SPECIFIC GRAVITY (G) 1

8 COMPRESSABILITY FACTOR (Z) 1

Since DELTA P > P1/2. Therefore, flow is critical.

Formula for Cv Calculation ( Flow By Volume )

Cv = (Q / 295) S (G x T x Z) / (DELTA P x (P1 + P2))

Cv(max) = #DIV/0! Cv(Nor) = #DIV/0! Cv(Min) = #DIV/0!


Since DELTA P < P1/2. Therefore, flow is subcritical.
Since DELTA P > P1/2. Therefore, flow is critical.

q1 q2 q3
q 10 20 17.99

CV 2.6 17 14.1

CV1 CV2
q1 q2 q3
q 4740 6420 5580.00
CV 32 36 34.0
CV1 CV2
CONVERSIONS :

1 TO CONVERT PRESSURE.
INPUT VALUE IN BARA
FROM Kg/Cm2 (g) 3 3.9551

FROM BAR 0.001 1.0140

FROM mm OF wc 10 0.001 bar

2 TO CONVERT TEMPERATURE.
INPUT VALUE IN 0K.

FROM 0 C 45 318

1.0135 1.0135
1.014 1.014
1.0149 1.0149
SHEET FOR VALVE SIZING CALCULATIONS FOR FLOW IN KG / HR & DP > P1/2

CONDITION - FLOW MEDIUM GAS / FLOW IS BY WEIGHT.

INPUT DATA

1 SERVICE FLUID GAS

2 FLOW RATE (1000 Kg/hr) MAX / NOR / MIN (w) 120


3 INLET PRESSURE (P1) BARA 6.1
4 OUTLET PRESSURE (P2) BARA 2
5 DELTA P - SIZING (BAR) 4.1
6 FLUID TEMPERATURE (T) 0K 373
7 SPECIFIC GRAVITY (GF) 1.16

8 COMPRESSABILITY FACTOR (Z) 1

9 CRITICAL FLOW FACTOR 0.8

Since DELTA P > P1/2. Therefore, flow is critical.

Formula for Cv Calculation ( Flow By Weight )

Cv = 54.5 w S Z / (CF x P1 x S GF )

Cv(max) = 1244.3 Cv(Nor) = 0.0 Cv(Min) = 0.0


G / HR & DP > P1/2

GAS

Since DELTA P < P1/2. Therefore, flow is subcritical.


Since DELTA P > P1/2. Therefore, flow is critical.

Where Gr = Specific Gravity of the


fluid at flowing temperature.

Gr = G x ( 288 / T ) = 0.896
FROM mm OF wc 0.000

CONVERSIONS :

1 TO CONVERT PRESSURE.
subcritical. INPUT VALUE IN BARA
FROM Kg/Cm2 (g) 1.0130

FROM BAR 1.0130

2 TO CONVERT TEMPERATURE.
INPUT VALUE IN 0K.

FROM 0 C 100 373


bar
SHEET FOR VALVE SIZING CALCULATIONS.

CONDITION - FLOW MEDIUM GAS / FLOW IS BY VOLUME.

INPUT DATA

1 SERVICE FLUID GAS

2 FLOW RATE (m3/hr) MAX / NOR / MIN (Q) 1575 1365


3 INLET PRESSURE (P1) BARA 8.013 8.013
4 OUTLET PRESSURE (P2) BARA 7.513 7.513
5 DELTA P - SIZING 0.500 0.500
6 FLUID TEMPERATURE (T) 0K 333
7 SPECIFIC GRAVITY (G) 0.865

8 COMPRESSABILITY FACTOR (Z) 1

SELECTED Cv 258

Match Factor (M) 1

Since DELTA P < P1/2. Therefore, flow is subcritical.

Formula for Cv Calculation ( Flow By Volume )

DP = 0.0
GAS 343

220.5
8.013 Since DELTA P < P1/2. Therefore, flow is subcritical.

2.513 Since DELTA P > P1/2. Therefore, flow is critical.


5.500

q1 q2 q3
q 80 90 93.89

CV 230 258 268.9

CV1 CV2
CONVERSIONS :

1 TO CONVERT PRESSURE.
ow is subcritical. INPUT VALUE IN BARA
FROM Kg/Cm2 (g) 3 3.9551

FROM BAR 1.0130

FROM mm OF wc 10400 1.010

2 TO CONVERT TEMPERATURE.

INPUT VALUE IN 0K.

FROM 0 C 273
VALUE IN BARA
3.9551

1.0130

1.010 bar