PASOLINK FAMILY

4/6GHz 7/8GHz 11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 38GHz


SERIES/MODEL SYSTEM MODULATION INTERFACE 3.6-7.1 7.1-8.5 10.7-11.7 12.7-13.2 14.2-15.3 17.7-19.7 21.2-23.6 24.2-27 37-40

PASOLINK V3 PDH 4PSK 2x2MB


4x2MB
8x2MB
16x2MB
1x8MB
1x34MB

PASOLINK V4 PDH 4PSK 2x2MB


4x2MB
8x2MB
16x2MB
(2x10/100Base-T)

PDH 16QAM + RS 8x2MB


PASOLINK+
16x2MB

1 x 34MB

SDH 32QAM+RS 21x2MB


(STM-0) (STM-1)

SDH 32QAM +RS STM-1


(STM-1) 2x10/100Base-T
SDH 128QAM+RS STM-1
(STM-1) 2x10/100Base-T
XPIC
SDH 128QAM+RS STM-1
(2xSTM-1) 2x10/100Base-T
System Overview
NEC has developed the PASOLINK NEO, a narrow band point-to-point digital microwave
relay system operating at radio frequency (RF) bands of
6/7/8/11/13/15/18/23/26/28/32/38/52 GHz.
GHz

The PASOLINK NEO system provides interface types of PDH, SDH and LAN. The
transmission signals are 5 to 48 x E1, 1 to 2 x E3, 1 to 2 x STM-1, 2/4 x 10/100 Base-T(X)
and GbE signals.

The systems consist of antennas, outdoor unit (ODU) and Indoor unit (IDU) same as PASOLINK series.
They are connected through a coaxial cable for each radio channel. Available configurations are non
protected type (1+0) and protected type (1+1). The protected type is available for twin-path type and
hot-standby type.
System Composition
• 1- Indoor unit (IDU) ( Modulation-Demodulation unit)
• 2- Outdoor unit (ODU) ( Transmit – Receive unit)
• 3- IF cable and connectors ( To connect the IDU & ODU)
• 4- Antenna on the required microwave band
• 5- Hybrid ( coupler ) in case of 1+1 one antenna configuration
• 6- RF cable ( If the ODU is not direct mounted to the antenna)

ODU (low band)


ODU (High band) TX RX
TX/RX
TX/RX
RX TX
RF RF

Antenna
Antenna IF
IF

MODEM Base Band


MODEM Base Band

IDU
IDU
System Configuration
A- Non protected system (1+0)
TX RX
IDU
ODU IDU
( 1+0 ) RX TX ODU
( 1+0 )

B- Protected system (1+1) hot standby


Single antenna configuration
TX/RX TX/RX
ODU-1 ODU-1
Modem-1 TX RX Modem-1
Switch H
Rx only H Switch
Modem-2 Rx only
RX TX Modem-2
ODU-2 ODU-2
System Configuration
C- Protected system (1+1) hot standby –Space diversity
Double antenna configuration
TX/RX RX TX TX/RX
ODU-1 ODU-1
Modem-1 RX
TX Modem-1
Switch
Rx only Switch
Modem-2 Rx only
Modem-2
ODU-2
RX ODU-2
RX

D- Protected system (1+1) Twin path –


Frequency diversity
TX/RX RX TX TX/RX
ODU-1 ODU-1
Modem-1 RX
TX Modem-1
Switch
Rx only Switch
Modem-2 RX Rx only
TX Modem-2
ODU-2
ODU-2
RX TX
PASOLINK NEO

Bit rate Free: 5/10/16/20/40/48E1, STM-1/2xSTM-1


Modulation Free : 4PSK,16/32/128QAM
Flexible Interface : PDH/SDH/LAN
Equipment Features
1. Advanced Technologies and Superb Performance

• High reliability and Quality.


• Excellent field proven MTBF.
• Low power consumption.
• 10 Base-T/100 Base-TX, 1000 Base-SX, 1000 Base-T (LAN interface).
• APS for STM-1 optical.
• VLAN implementation.

2. High System Gain / High spectrum efficiency

• High System Gain achieved by each modulation with Forward Error Correction
(FEC) Technology and distortion canceling technique called linearizer.
• High spectrum efficiency achieved by QPSK to 128QAM selectable technology.
• Allowing smaller antennas and reducing system cost.

3. Easy and Quick Installation

• IDU - ODU Interconnection : Only one coaxial cable and automatic equalization.
• Very Compact and Light.
• Various mounting methods for IDU, ODU and Antenna.
• Easy Antenna direction adjustment.
Equipment Features
4. Frequency Agility and Easy Tuning

• Field tunable local oscillator (Synthesizer)


• RF point frequency can be changed through Local Craft Terminal (LCT).
• Sub-band of type is changeable by replacing RF Filter.

5. System Flexibility

• (1+0) Non-protected or (1+1) Protected.


• 1+1 Hot Standby / Space Diversity / Twin Path System available.
• IDU is used commonly for 6 - 52 GHz.
• Changeable data transmission rate (4 to 48x2 Mbps, 1 to 2x34 Mbps, 155 Mbps,
2x155 Mbps, 10/100 Base-T(X), 1000 Base-SX, 1000 Base-T) at the same IDU.
• Software settable Modulation (QPSK/16QAM/32QAM/128QAM) of IDU.
• Common ODU for PDH/SDH/LAN.
• Wide Input Line Voltage range is -40.5 to -57Vdc.

6. Maintenance Facilities

• Local and remote supervision function on IDU through LCT or PNMTj


• Full front access at IDU for all cabling and user interface
• Loop back facility Near end base band, Far end base band IF loop back
• Pre-settable BER alarm point: 10-3, 10-4 or 10-5
Equipment Feature
7. Service Channels

• Engineering Order Wire (OW): IDU- IDU and Party line.

• SC1 & SC 2: V.11, 64 Kbps Contra-Co directional : Selectable


• SC3 & SC 4: RS232C , 9.6 Kbps
• SC LAN : SC LAN Sub-Interface ( In case of 155 MB Capacity )
64/128/192/265 Kbps or 2 Mbps Throughput.

• SV Channel commonality:
SV Commonality
Baseband Interface Flexibility

5/10/16E1 + 2Ether
4Ether + 4E1
ODU
Bitrate Free
• 5/10/20/40/48E1
• STM-1 IDU
• STM-2(310MB)
Modulation Free Interface Board
• 4PSK,16/32/128QAM

40/48E1
STM-1(elec.) STM-1(opt.)

PDH DIST CARD


(PDH Distribution Card) SDH ADD/DROP INTFC
For Nodal Solution
System Upgradeability
1+0
ODU

ODU 1+1
5E1Æ10E1Æ16E1
Upgrade Key New INTF ODU
+Upgrade Key
New MODEM New MODEM
New INTF ODU New ODU
+New ODU
+Upgrade Key
40E1Æ48E1
Upgrade Key New INTF
ODU ODU +Upgrade Key

ODU
Repeater
New IDU/ODU STM-1
V ODU +Upgrade Key
H

ODU

2xSTM-1/XPIC
Memory Card
APS (Automatic Protection Switching)

STM-1 OPT INTFC (W) Working Line STM-1 OPT INTFC (W)

STM-1 OPT INTFC (P) Protection Line STM-1 OPT INTFC (P)

SDH MUX SDH PASOLINK NEO

STM-1 OPT INTFC (W) Working Line STM-1 OPT INTFC (W)

STM-1 OPT INTFC (P) Protection Line STM-1 OPT INTFC (P)
Cross Polarization Interference Canceller
(XPIC)
The transmission capacity of the existing STM-1 equipment can be improved up to
2xSTM-1 by adding one more IDU, ODU and XPIC cable kit and additional firmware.

IDU ODU 1 ODU 1 IDU


V V

OMT OMT

H H
IDU ODU 2 ODU 2 IDU
Switchover Control
• Switchover Modes:

1. Automatic Switchover:
Switching is automatically initiated if any failure or abnormality was detected in
the online section.

2. Manual Switchover:
The operator initiate this switchover by LCT or PNMT for the maintenance and
test purposes. The manual switching has two selection Manual or Forced
switchover.

• Switching Priority:
The switching priority is only applied under automatic switching control.
System Performance Parameters QPSK
Frequency
6 7-8 11 13 15 18 23 26 28 32 38 52
Band, ( GHz )

Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0- 51.4-
51.4-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0 52.6

RF Direct Mount N/A NEC Original

N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR100 PBR120 PBR140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320 N/A

Output Power,
+29 +25 +25 +23 +24 +24 +23 +23 +22 +18 +3
dBm
0 to 10
Power Control 0 to 30 dB 0 to 25 dB
dB
Frequency
± 6 ppm
Stability

Threshold Level (dBm measured at Antenna port) BER = 10 -6

CS = 28 (27.5) MHz -84 -83 -83 -83.5 -83.5 -83.5 -83 -83 -81.5 -81.5 -78

14 (13.75) MHz -87 -86 -86 -86.5 -86.5 -86.5 -86 -86 -84.5 -84.5 -81

7 MHz -90 -89 -89 -89.5 -89.5 -89.5 -89 -89 -87.5 -87.5 -84

BER = 10-3 Above value with -1.5 dB


System Performance Parameters QPSK
Frequency
6 7-8 11 13 15 18 23 26 28 32 38 52
Band, ( GHz )

System Gain (dBm measured at Antenna port) BER = 10 -6

CS = 28 (27.5) MHz 113 108 108 106.5 107.5 107.5 106 106 103.5 99.5 81

14 (13.75) MHz 116 111 111 109.5 110.5 110.5 109 109 106.5 102.5 84

7 MHz 119 114 114 112.5 113.5 113.5 114 114 109.5 105.5 87

BER = 10-3 Above value with +1.5 dB

Maximum Input
-15 dBm (No Error)
Level dBm

Residual BER Less than 10-12 at RSL = -30 dBm


System Performance Parameters 16QAM
Frequency
6 7-8 11 13 15 18 23 26 28 32 38
Band, ( GHz )

Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0

RF Direct Mount N/A NEC Original

N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR 100 PBR 120 PBR 140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320

Output Power, dBm +25 +21 +21 +21 +19 +19 +18 +18 +17 +13.5

Power Control 0 to 24 dB, in 1 dB step variable


Frequency
Stability
± 6 ppm

Threshold Level (dBm measured at Antenna port) BER = 10 -6


(dBm

CS = 28 (27.5) MHz - 77 -76 -76 -76.5 -76.5 -76.5 -76 -76 -74.5 -74.5
14 (13.75) MHz -80 -79 -79 -79.5 -79.5 -79.5 -79 -79 -77.5 -77.5
7 MHz -83 -82 -82 -82.5 -82.5 -82.5 -82 -82 -80.5 -80.5
3.5 MHz -86 -85 -85 -85.5 -85.5 -85.5 -85 -85 -83.5 -83.5
BER = 10-3 Above value with +1.5 dB

System Gain (dBm measured at Antenna port) BER = 10 -6


(dBm
CS = 28 (27.5) MHz 102 97 97.5 95.5 95.5 95.5 94 94 91.5 89
14 (13.75) MHz 105 100 100.5 98.5 98.5 98.5 97 97 94.5 92
System Performance Parameters 16QAM
Frequency
6 7-8 11 13 15 18 23 26 28 32 38
Band, ( GHz )

CS = 7 MHz 108 103 103.5 101.5 101.5 101.5 100 100 97.5 95

3.5 MHz 111 106 106.5 104.5 104.5 104.5 103 103 100.5 98

BER = 10-3 Above value with +1.5 dB

Maximum Input
-20 dBm for the BER less than 10-
10-3
Level dBm

Residual BER Less than 10-12 at RSL = -30 dBm


System Performance Parameters 32 QAM
Frequency
6 7-8 11 13 15 18 23 26 28 32 38 52
Band, ( GHz )
Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0- 51.4-
51.4-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0 52.6
RF Direct Mount N/A NEC Original
N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR100 PBR120 PBR140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320 N/A

Output Power,
+25 +21 +21 +21 +19 +19 +18 +18 +17 +14.5 -3
dBm
Power Control 0 to 30 dB 0 to 6 dB
Frequency
± 6 ppm
Stability

Threshold Level (dBm measured at Antenna port) BER = 10 -6

CS = 28 (27.5) MHz -75.5 -74.5 -74.5 -75 -75 -75 -74.5 -74.5 -73 -73 -69.5

BER = 10-3 Above value with -1.5 dB

System Gain (dBm measured at Antenna port) BER = 10 -6

CS = 28 (27.5) MHz 100.5 95.5 95.5 96 94 94 92.5 92.5 90 87.5 66.5

BER = 10-3 Above value with +1.5 dB


Maximum Input
-20 dBm for the BER less than 10-
10-3
Level dBm
Residual BER Less than 10-12 at RSL = -30 dBm
System Performance Parameters 128 QAM
Frequency
6 7-8 11 13 15 18 23 26 28 32 38
Band, ( GHz )

Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0

RF Direct Mount N/A NEC Original

N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR 100 PBR 120 PBR 140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320

Output Power, dBm +25 +25 +21 +21 +21 +19 +19 +18 +18 +17 +14.5

Power Control 0 to 20 dB, in 1 dB step variable


Frequency
Stability
± 6 ppm

Threshold Level (dBm measured at Antenna port) BER = 10 -6


(dBm
CS = 28 (27.5) MHz - 69.5 -68.5 -68.5 -69 -69 -69 -68.5 -68.5 -67 -67

BER = 10-3 Above value with -1.5 dB

System Gain (dBm measured at Antenna port) BER = 10 -6

CS = 28 (27.5) MHz 94.5 89.5 89.5 90 88 88 86.5 86.5 84 81.5

BER = 10-3 Above value with +1.5 dB

Maximum Input
-20 dBm for the BER less than 10-
10-3
Level dBm
Residual BER Less than 10-
10-12 at RSL = -30 dBm
IDU Performance Parameters(1/2)
No. Item SPECIFICATION

PDH SDH LAN


1 IDU Type 1+0 Expandable / 1+1
2 Modulation Type QPSK/16/32/QAM 128 QAM QPSK/16/32/QAM
3 Baseband Interface E1: E3: STM-1 : 10/100 Base-T(X)
2.048 Mbps ± 50 34.368Mbps 155.52 Mbps ± 20 1000 Base-SX
ppm
±20 ppm ppm 1000 Base-T
Channel Number 4/8/16/32/48 1/2 1/2 2/4
Total Capacity 8/16/32/64/96 34/68 Mbps 155/ 2x155 10/20/40/80/100/
Mbps Mbps 100+50/, 75+75 Mbps
4 Service Channels V.11(Contra/Co-directional) x 2 channels,RS-232 x 2 channels
5 LCT Security Levels 2 levels
6 Loop Back Near End, Far End Baseband Loop Back and IF Loop Back
7 BER ALM Adjustable 10-3/ 10-4/ 10-5
Frequency Changing Direct entry or Table Download entry :Available
TX Output Control Manual Control, Automatic Control and Mute Control.
PMON PMON Items;
a) OFS, b) BBE, c) ES, d) SES, e)SEP, f) UAS
IDU Performance Parameters(2/2)
SPECIFICATION
No. Item
PDH SDH LAN
PMON Metering Items
a) Output power level (TX PWR), b) Received signal level (AGC V)
c) Bit error rate (BER MON)
LAN monitoring Items;
a) RX Unicast, b) RX Broadcast, c) RX Multicast,
b) d) RX Pause, e) RX CRC error
8 LED Display CTRL ・IDU Alarm (Red)
・Maintenance (Yellow)
・Memory Access (Yellow)
MODEM ・Operating PWR (Green)
・ODU Alarm (Red)
・MD/CBL Alarm (Red)
・TX status (Green)
・RX status (Green)
・XPIC Reset (Yellow) for XPIC only
PDH INTFC ・Module alarm (Red)
SD INTFC ・Module alarm (Red)
・Online (Green) for APS only
LAN/WS INTFC ・Module alarm (Red)
Interconnection between IDU & ODU
No. Item SPECIFICATION
1 Interconnection Single Coaxial Cable per system / 50 ohms

2 Standard Type of Cable 5D-FB, 8D-FB (standard)


IF cable adapter 10D-FB
3 Signals IF signal, alarms, control, monitoring and
power source
4 Maximum Cable Length 150 m (5D-FB)
300 m (8D-FB)
350 m (10D-FB)
5 Cable Equalization Automatic level equalization
6 Guaranteed temperature range 33oC to +50oC (workable : -40oC to +55oC)
Alarm output Items
Relay Alarm Output
No. Alarm Item on LCT/PNMT ALM Indication
RL1 RL2 RL3 RL4 RL5 RL6
1 MAINT MAINT
2 PS ALM PWR
3 IDU CPU ALM --
4 ODU ALM1 ODU
5 ODU ALM2
6 ODU CPU ALM1 ODU Blinking
7 ODU CPU ALM2
8 TX PWR ALM1 ODU
9 TX PWR ALM2
10 TX IN ALM1 ODU
11 TX IN ALM2
12 APC ALM1 ODU
13 APC ALM2
14 RX LEV ALM1 ODU
15 RX LEV ALM2
16 IF CABLE SHORT ALM1 IDU/MD CBL
Blinking
17 IF CABLE SHORT ALM2
18 IDU ALM IDU
19 HIGH BER ALM IDU
House keeping output Items
Relay Alarm Output
No. Alarm Item on LCT/PNMT ALM Indication
RL1 RL2 RL3 RL4 RL5 RL6
1 HK OUT1 PNMT only

2 HK-OUT2 PNMT only

3 HK-OUT3 PNMT only

4 HK-OUT4 PNMT only

5 Cluster ALM Out1 PNMT only

6 Cluster ALM Out2 PNMT only

7 Cluster ALM Out3 PNMT only

8 Cluster ALM Out4 PNMT only

Notes: The Factory setting


The HK that cane be configured

The relays RL1 & RL2 can’t be changed


House keeping Input Items
Relay Alarm Output
No. Alarm Item on LCT/PNMT Event Indication
IN1 IN2 IN3 IN4 IN5 IN6
1 HK-IN1 PNMT only

2 HK-IN2 PNMT only

3 HK-IN3 PNMT only

4 HK-IN4 PNMT only

5 HK-IN5 PNMT only

6 HK-IN6 PNMT only

7 Cluster ALM Input1 PNMT only

8 Cluster ALM Input2 PNMT only

9 Cluster ALM Input3 PNMT only

10 Cluster ALM Input4 PNMT only


PASOLINK NEO IDU

PASOLINK NEO IDU ( 1+0 )

PASOLINK NEO IDU ( 1+1 )


IDU Composition
IDU Shelf :
IDU Modules
H2930 MDP-
MDP-150MB-
150MB-1AA
No. UNIT/MODULE NAME Remarks
1+0 1+1
Expandable System
1 H2931 RACK
2 H2940 MODEM QPSK/16QAM/32QAM/128QAM
H2940 MODEM
3
H3040 DC-DC CONV -20 to –60 VDC
H2960 STM-1 INTFC STM1-E/O-S-1.1/L-S-1.1
4 H2965 LAN/WS INTFC SDH 2-Port-LAN
H3021 GbE INTFC SDH-GbE
H2960 STM-1 INTFC STM1-E/O-S-1.1/L-S-1.1 for APS
5
H2965 LAN/WS INTFC WS-SC-LAN/WS/SC-LAN
H2980 16E1 INTFC PDH-16E1 e/w 2 Port LAN
6 H3000 48E1 INTFC PDH-48 E1
H3010 E2 INTFC PDH-E3 e/w 4/8E1, 2 Port LAN
7 H2950 CTRL

Usually Provided

Optionally provided
Base Band Interface
Item Parameters Panel Details Available Capacity
Main STM1-E STM1-E STM-1 Electrical (IEC 1.0/2.3 coaxial) 155 Mbps
Interface
STM1-O-S11 STM1-O-S11 STM-1 Optical S-1.1 (connector type LC) 155 Mbps
STM1-O-L11 STM1-O-L11 STM-1 Optical L-1.1 (connector type LC) 155 Mbps
SDH-2P-LAN SDH-2P-LAN 2 port 10/100 Base-T(X) 155 Mbps
SDH-GBE SDH-GBE 1000 Base-T (RJ-45) or 1000 Base-SX (LC) 155 Mbps
PDH-16E1 PDH-16E1 16E1 + 2 port LAN (D-sub 75/120 ohm selectable 10 - 80 Mbps

PDH-48E1 PDH-48E1 48E1 (MDR 75/120 ohm selectable) 80 -108 Mbps


PDH-4P-LAN PDH-4P-LAN 4 port LAN only for 32QAM 100 Mbps 108 Mbps
PDH-1E3 PDH-1E3 1xE3 (34 Mbps) interface 40 Mbps 40 Mbps
PDH-2E3 PDH-1E3 2xE3 (34 Mbps) interface 80 Mbps 80 Mbps
Sub WS-SC LAN WS (E1) and WC/Service Channel LAN for STM-1 155 Mbps
Interface
WS WS (E1) 155 Mbps
SC LAN Service Channel LAN for STM-1 155 Mbps
NOT USED Blank Panel -
Baseband Interface
BaseBand Interface 48 E1 Interface

2M IN/OUT-A/-B/-C 16 E1 interface in each connector


( MDR Connector )

Input/Output Signals: up to 48 E1 signals


Bit Rate: 2.048 Mbps +/- 102.4 bps
Code: HDB3
Impedance: 75 ohms unbalanced or 120 ohms balanced
BaseBand Interface 16 E1 Interface

2M IN/OUT-A/-B/-C 8 E1 interface in each connector.


Input/Output Signals: up to 48 E1 signals
Bit Rate: 2.048 Mbps +/- 102.4 bps
Code: HDB3
Impedance: 75 ohms unbalanced or 120 ohms balanced

PORT 1/PORT 2 LAN interface port 1 and port 2 are separated.


(RJ-45) 8 to 40 Mbps shared when 16 E1 to 0E1 are used.
10/100 base-T(X) Auto sensing or fixed
Full duplex or Half duplex
Store and Forward
BaseBand Interface 16 E1 Interface
BaseBand Interface STM-1 Interface
STM-1 Electrical Interface STM-1 IN/OUT IEC Electrical STM-1 PUT/OUTPUT,
169-13
Type: G.703
Rate: 155.520 Mbps
Level: 1 Vp-p
Code: CMI
Impedance 75 ohms, unbalanced

ALM: To indicate any ALM action occurred in the Interface


LOS of STM-1 detected from the DTE or from DMR.
Frame Synchronization of input signal is lost
STM-1 Optical Interface BER is worse than ( 10-3~10-5 selectable ) DMR or MUX
BER is worse than ( 10-5 ~ 10-9 selectable ) DMR or MUX
Mounted module is not matched with the inventory

STM-1 IN/OUT LC Optical STM-1 INPUT/OUTPUT,


Type: G.957
Rate: 155.520 Mbps
Code: NRZ
Wavelength: 1310 nm
Working in APS: ONLINE ON Level: L-1.1: 0 to -8 dBm (TX) / -10 to -34
SYANDBY APS: ONLINE OFF dBm (RX)
NO APS: ONLINE OFF S-1.1: -8 to -15 dBm (TX) / -8 to -28
dBm (RX)
MODEM Unit

The MODEM provides the QPSK/16QAM/32QAM/128QAM Modulation and Demodulation for E1/E3 (PDH),
10/100 base-T (LAN), or STM-1 (SDH) data transmission in addition to the following main functions:

Forward Error Correction using RS/Interleaving.


XPIC ODU Synthesizer synchronization control.
Interfered signal from opposite polarization cancellation ( XPIC ).
IDU/ODU Power Supply.
System Power On/Off.
Interfaces/Switches/Indications
XIF IN/XIF OUT Only used for XPIC system
IF Signal of opposite polarization.
IF Signal for opposite polarization output.
140 MHz
75 ohms
XPIC CTRL ( D-SUB 15 pins) Serial Port
Only used for XPIC system between two IDUs.
SEL V ( MOLEX M5557-4R, 4pins) , ( DC IN)
-48VDC(negative ) , + (positive, Ground)
G Ground Terminal( 5mm2 cable)
IF IN/OUT Tx Frequency: 340 MHz
Rx Frequency: 140 MHz
Impedance : 50 ohms
Connecting IF Cable length: 5D-FB: less than 150 m
10D-FB: less than 300 m
12D-FB: less than 350 m
PWR Switch IDU/ODU Turn Power on
PWR To indicate the power switch of the MODEM is turned on.
MD/CBL Blinks when IF cable is short circuit.
TX ( only 1+1 ) Selected status of ODU TX
RX (only 1+1 ) Selected status of MDOEM RX output signal
XPIC RESET XPIC function is off condition
ODU To indicate any alarm occurred at ODU Circuit.
Power Supply
Power Supply

When the ODU which connected is not NEO connected to IDU NEO, it is recommended to install the optional
DC-DC CONV into the IDU.

The ODU will be shorten ODUs life or may be damaged if not used optional DC-DC CONV module.
CTRL Unit CALL Transmit the EOW calling to sound
the BUZZER in the opposite station
PROTECT Prevent service interruption in case
of CTRL module replacement.

EOW Jack for OW headset

To indicate the maintenance


Condition.
The Memory card is accepted
LCT LCT and PNMT An event occurred on IDU.
Interface
USB 1.1 AUX/ ALM D-
SC IN/OUT
D-Sub F, 44 pins
Connector Type B EOW input 1 (+) 1 16 EOW input 1 (-
(-) 30 BUZZER input 1
DSC1 V.11 64 Kbps
EOW output 1 (+) 2 17 EOW output 1 (-
(-) 31 CALL output 1
NMS PNMS Interface EOW input 2 (+) 3 18 EOW input 2 (-
(-) 32 BUZZER input 2
DSC2 V.11 64 Kbps
EOW output 2 (+) 4 19 EOW output 2 (-
(-) 33 CALL output 2
10 Base-T Ground 5 34

RJ-45 RL 6 ( NO ) 6 20 RL 6 ( COM ) 35 RL 6 ( NC ) DSC3 RS232C 9.6


RL 5 ( NO ) 7 21 RL 5 ( COM ) 36 RL 5 ( NC )
RL 4 ( NO ) 8 22 RL 4 ( COM ) 37 RL 4 ( NC ) Kbps
NE Back to Back RL 3 ( NO ) 9 23 RL 3 ( COM ) 38 RL 3 ( NC )
Connection RL 2 ( NO ) 10 24 RL 2 ( COM ) 39 RL 2 ( NC ) DSC4 RS232C 9.6
10 Base-T
RL 1 ( NO ) 11 25 RL 1 ( COM ) 40 RL 1 ( NC ) Kbps
ALM HK2 IN (+) 12 26 HK4/CL3 IN (-
(-) 41 HK6/CL1 IN (-
(-)

RJ-45 ALM HK2 IN (-


(-) 13 27 HK4/CL3 IN (+) 42 HK6/CL1 IN (+) NE2 RS485 ASYNC.
ALM HK1 IN (-
(-) 14 28 HK3/CL4 IN (-
(-) 43 HK5/CL2 IN (-
(-)
ALM HK1 IN (+) 15 29 HK3/CL4 IN (+) 44 HK5/CL2 IN (+)
SC IN/OUT D-
D-Sub F, 44 pins
Outdoor Unit ( 6 - 52 GHz )

RX LEV MONITOR
• The nominal power supply voltage is -48 V DC.
However, the range of the unit is able to fit for
Turn OFF the DC
power before removing
nominal voltages of +24 V by additional unit.
the IF cable • The weight of ODU is 3 Kg.

Frame Ground
Outdoor Unit ( ODU )

• The transmitter-receiver is designed to handle an 8-155 Mbps digital signal in the 6-52 GHz
bands. The equipment is designed to withstand severe weather conditions. To achieve high
system gain performance, quadrature phase-shift keying (QPSK) modulation is applied. And to
achieve high frequency efficiency performance, 16/32/128-quadrature amplitude modulation
(16/32/128QAM) is applied. This ODU can apply to each modulation.

• Advanced integrated circuit technology, e.g., MMIC and MIC, is applied to the entire RF circuit in
ODU.
Outdoor Unit
Hybrid Combiner
NEC has developed Hybrid Combiner/Divider over the full range of microwave frequencies for PASOLINK Series digital microwave
radio point-
point-to-
to-point fixed wireless systems. This Hybrid Combiner/Divider comprises
comprises directional coupler, antenna interface, radio
mounting interfaces and polarizers.
polarizers. The RF signal power received by the single polarized antenna is
is equally distributed and sent to
two outdoor units through the Hybrid Combiner/Divider for 1+1 protected
protected systems.
There are two types of NEC Hybrid Combiner/Divider, one is coaxial
coaxial cable connection type for 6/7/8 GHz Bands and the other is
WG connection type for 11 – 52 GHz Bands. NEC Hybrid Combiner/Divider is suited for Andrew or RFS Antenna, and all NEC
ODUs.

6/7/8 GHz Coupler (N-type) 11 ~ 38 GHz Coupler (N-type)


10 Coupler
The RF signal power received by the single polarized antenna is unequally distributed to two outdoor units in
the ratio of 9 to 1 through the 10 dB Coupler for 1+1 protected systems. Using this 10 dB Coupler, regular
side signal level could be kept higher than in using 3 dB equal Combiner/Divider.
There are two types of NEC 10 dB Coupler; one is coaxial cable connection type for 6/7/8 GHz bands and the
other is WG connection type for 11 - 38 GHz Bands. NEC 10 dB Coupler is suited for Andrew or RFS
Antenna, and all NEC ODUs.

6/7/8 GHz Coupler (N-type) 11 ~ 38 GHz Coupler (N-type)


Ortho – Mode Transducer ( OMT )
OMT enables dual polarization feature to double the transmission capacity for the PASOLINK
system. NEC OMT has Wave Guide connection type for 11-38 GHz Bands, which is suited for
RFS Antenna and all NEC ODUs.

The OMT comprises Ortho-Mode transducer, antenna interface


and radio mounting interfaces.
ODU Mounting Configurations
Suitable configuration can be selected from various ODU mounting styles:
• Direct Mounting on Antenna
• Separate Mounting with Antenna using Waveguide or Coaxial Cable
• 1+1 system with Hybrid Combiner / Divider
• 2+0 system with Dual Polarization Antenna

1+0 System Configuration ODU

Antenna

11 - 52 GHz Direct Mounting of 1+0 PASOLINK ODU


ODU Mounting Configurations

11 - 38 GHz Remote Mounting of 1+0 PASOLINK ODU

6/7/8 GHz Remote Mounting of 1+0 PASOLINK ODU


ODU Mounting Configurations
1+1 System Configuration

11 - 52 GHz Direct Mounting of the 1+1 PASOLINK ODU


(One Antenna with Hybrid Combiner unit)
ODU Mounting Configurations

11 - 38 GHz Remote Mounting of 1+1 PASOLINK ODU


with Hybrid Combiner

11 - 38 GHz Remote Mounting of 1+1 PASOLINK ODU


with two antennas
ODU Mounting Configurations

6/7/8 GHz Remote Mounting of 1+1 PASOLINK ODU


with Hybrid Combiner and one antenna

6/7/8 GHz Remote Mounting of 1+1 PASOLINK ODU


with two antennas
ODU Mounting Configurations
2+0 System Configuration
Dual Pol. Antenna System for Adjacent channel or
Co-Channel assignment)

11 - 38 GHz Direct Mount


Dual Pol. System

6/7/8 GHz Remote Mount Dual Pol. System


11 - 38 GHz Remote Mount
Dual Pol. System
PASOLINK MONITOR
•Meter – Indicates the Receive
level as a dc voltage
•OW Indicator – Lights when the
OW-ON/OFF switch is set to ON.
Under this condition if the indicator is
not lit replace the battery.

•Battery – use 6F22(UB) / 9V battery

•Head set Jack – connects the


•OW ON/OFF SW – when set to ON headset for OW communication
enables OW communication
between the IDU and the ODU. •RX LEV/OW IN connector –
connect the OW/RX Lev monitor to
•VOL control – Adjust the level of the ODU using the provided coaxial
the OW RX signal. cable
Loop Back Control

(d)

(a) STM-1 near-end loopback (STM-1 LB1) at the 150M INTFC/OPT INTFC module
(b) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC module from LCT
(c) IF loopback (IF-LB) at the MODEM module (Local only)
(d) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC Module from PNMT/PNMS

•Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent
stations from the PNMS and PNMT are disabled.
PASOLINK NEO Installation
Before going to any site,

please be sure you completely prepared the following items:


1-The installation tools.
2-The test equipment ,materials ,and tools.( for test work only)
3-Site installation drawings.
4-All labels/stickers (hard and soft copy)
5-Frequency plan and system configuration documents.
6-Test procedure and test data sheets ( for test work only)
7-Confirm access to site/station.
8-Check the condition of the vehicle to be used.
9-Make sure you and your staff are in good conditions (physically)
10-Confirm the site/station entrance conditions.
11-Move to site/station safely.
1-INDOOR
1-INDOOR Unpackingofof
Unpacking Unpacking
Unpacking Unpackingofof19"
19"
Unpacking
INSTALLATION Accessories
Accessories ofIDU
of IDU rack(if
(ifsupplied)
supplied)
INSTALLATION rack

IFConnector
IF Connector&&Power
Power
Connectortermination
termination Confirm 19" Rack Location
Connector
& DC-Power Source

19"rack
19" rackfixing
fixing
FollowThe
Follow The
terminationProcedure
termination Procedure IDU
Mounting
RackEarthing
Rack Earthing
Connection
Connection
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection

IDUGrounding
IDU GroundingConnection
Connection

Follow Start up and set up Connectthe


Connect thePower
Power
NESIC CAIRO
Procedure
UNPACKING IDU

•Open the carton take out the Accessories Carton


•Take out the cushioning materials of the IDU Carton
•Take out the IDU with the antistatic bag from the carton
•Take out the IDU from the antistatic bag
•Inspect IDU
IDU MOUNT
FRONT POSITION
More than one
rack unit

WALL

Align the IDU to the mount position


When mounting the IDU in a 19 inch
rack, leave a space of 200mm to
Fix each side of the IDU to the rack
the rear section and space of one
with (M5) screws
rack unit to the top and bottom.
CENTER POSITION

More than one


rack unit
Mount the two brackets to the IDU
Align the IDU to the center mount position
with four screws
and fix each side with (M5) screws
CONNECTOR & POWER CABLE

Power
Connector

Socket Contact
Power
Cable
1-Remove 3.0 to 3.5 mm of Insulation 1

2
2- Set the socket contact to the following
position onto the hand crimping tool

Crimping Type dia. of Cable Position


57026-5000 Ф 1.5 to 1.8 1
Ф 1.8 to 2.2 2
57027-5000 Ф 2.3 to 2.6 1
Ф 2.6 to 3.1 2
Hand Crimping
tool (57026-5000)
3- Squeeze the handle of the hand crimping tool, insert cable into socket
contact

4- Cable should fit, so insulation and bare wire are arranged as shown,

5- Squeeze the handle of the hand crimping tool until ratchet is released.
5-Squeeze the
handle of the hand
crimping tool until
ratchet Is released

6- Insert socket contacts to power


connector till they locked and be sure
it is well fixed. (-48 V)

(0 V)

NESIC CAIRO
1-OUTDOOR
1-OUTDOOR Unpackingofof
Unpacking Unpacking
Unpacking Unpackingofof
INSTALLATION
INSTALLATION Accessories ofODU
ODU
Unpacking
Accessories of Antenna
Antenna
FLOWCHART
FLOW CHART

IFConnector
IF Connector Removethe
Remove theODU
ODU Antenna bracket
cover,Confirm
cover, Confirmthe
the assembling,
Polarity
Polarity Confirm the Polarity

FollowThe
Follow The
terminationProcedure
termination Procedure ODU
Mounting Refer to the Antenna
assembling guide
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection

ODUGrounding
ODU GroundingConnection
Connection

Connect to IDU & Follow IFCable


IF CableLaying
Laying
Start up and set up Procedure
UNPACKING ODU

6/7/8 GHz ODU 11- 38 GHz ODU


•Open the carton
•Open the carton
•Take out the ODU with cushioning materials
•Take out the ODU with the cushioning materials
•Remove the cushioning materials from the ODU
•Remove the cushioning material from the ODU
•Take out the ODU from the antistatic bag
•Inspect ODU
•Inspect ODU
POLE MOUNTING BRACKET

Bracket for 6/7/8 GHz Band ODU

New Type Bracket for 11-38 GHz Band ODU Old Type Bracket for 11-38 GHz Band ODU
POLE MOUNTING BRACKET

NEW TYPE BRACKET

NEW TYPE BRACKET


V /H POLARIZATION (1+1)
V - POLARIZATION NEC Hybrid Quasar Hybrid
SCREWS

SCREWS

SCREWS

H - POLARIZATION ANTENNA
CONNECTION
UNIT

PROCEDURE FOR SETTING V/H POLARIZATION USING HYBRID

ANTENNA SIDE HYBRID SIDE


•The hybrid is set to V-polarization
•Loosen the four screws with allen keys and rotate
when shipped from the factory
the antenna connection unit to the required
polarization position •Remove the two screws.
•Tighten the four screws. •Rotate the two plates to the position required for the
required polarization and fix them in position with
the screws
ANTENNA DIRECT MOUNT – V/H POL

PROCEDURE FOR SETTING V/H POLARIZATION

•When vertical polarization is required, rotate the •When horizontal polarization is required, rotate the
IDU so that the plate marked with V is pointing up. IDU so that the plate marked with H is pointing up.
Fix the ODU in this position Fix the ODU in this position
USE OF O-RINGS

•Do not use both small O-ring and large O-ring


simultaneously

•O-ring size is different forf different frequency


bands
ODU MOUNT
Local Craft Terminal (LCT)
The Local Craft Terminal (LCT) is used to access, setup, manage, monitor and controls the
PASOLINK NEO PDH/SDH Microwave Radio system.

Hardware Requirement:

H.D.D: 100MB or higher empty disk capacity


RAM: 256 MB
Display: LCD 1,024 x 768
CD-ROM Drive
Serial Port
USB Port
USB Cable with USB-B Connector

Software Requirement:

OS: Windows 2000/XP


IE6.0 SP2
Java Runtime Environment V1.5.0_05 or higher
LCT Setup Procedures
1. Installation of USB Driver:
LCT Setup Procedures
2. Dial-up Connection:
LCT Setup Procedures
2. Dial-up Connection:
LCT Setup Procedures
2. Dial-up Connection:
LCT Setup Procedures
1. Installation of Java Run Time:
Java Run Time Environment V1.5.0_05 or higher is required.
LCT Operation
Connect to the USB port of IDU using the USB cable

Connect using the dial up connection “LCT”.

Open the Internet Explorer

Enter URL Address: http://172.17.254.253 of the IE and press the “Enter” key.

The login window will then enter your login information User ID and password in the entry field then
press login

User ID Password Privilege


Admin 12345678 Access to the LCT
and control
User No password Monitoring only
LCT Operation
Description of LCT Menu Convections

Yellow for MAINT status

To execute the commands

To logout from the LCT


Then a confirmation
Message will appear to
Confirm or cancel.

To show the status of


Command execution if OK
Or no response.
LCT Main Menu
Equipment Setup Menu
From the “User Interface” menu button, you can select PDH E1, PDH with LAN or SDH STM-1
If you select PDH setup, the PDH setup items which are applicable to setup will appear.
And for SDH, the SDH setup items which are applicable to setup will appear.
Equipment Setup (1/3)
SDH Equipment Setup
Equipment Setup (2/3) SDH Equipment Setup
Equipment Setup (2/3)
PDH Equipment Setup
Equipment Setup (2/3) PDH Equipment Setup

For QPSK

For 16QAM

For 32QAM
Equipment Setup (3/3)
ODU FREQ. INFO

Edit the point of TX frequency which should


be within the range of the Start and Stop
Sub-band indicated on the plate of the ODU.

The Rx frequency is automatically calculated


According to the Shift frequency.

For Twin path systems, two different RF


Frequencies should entered.

ID1 to ID16 is available and ID17 to ID32 is


Available for XPIC system.
Inventory
Inventory

• Select “Open” or “Close” to apply to the output mode to apply for event output.

• From INPU1 to INPUT6 can be assigned as housekeeping Alarm HK1 to HK6.

• From INPUT3 to INPUT6 can be assigned as Input Cluster Alarm Cluster IN1 to
Cluster IN4.

• From OUTPUT1 to OUTPUT4 can be assigned as HK3 to HK6.

• From OUTPUT1 to OUTPUT4 can be assigned as Cluster OUT1 to OUT4.

Cluster can be used as IN + OUT ≤ 4

• Click “SET” Command to execute.


Maintenance PDH Maintenance

A pop-up menu will appear


To select which Ch. Will be
looped
Maintenance SDH Maintenance
Maintenance
• Select ‘CTRL’ for IDU or ‘ODU’ for No.1 or
No.2 and click the ‘execute button’.

• Check “With ROM “Program” Switching”


Control box when the program file for “CTRL”
Or “ODU” is newly downloaded and existing
Program file will be replaced with the new
one.
• Reset the “CTRL” card will affect the radio
link
Maintenance
Maintenance
Provisioning (1/4) PDH Provisioning
Provisioning (2/4) PDH Provisioning

ATPC MODE

MTPC MODE
Provisioning (3/4) SDH Provisioning

Assignable
For RS-232C-1 or -2
Assignable
For V.11-1 or -2

ATPC MODE

MTPC MODE
Provisioning (4/4)
Provisioning

Metering
PMON (Current) for PDH Equipment
PMON (History)
PMON (History)
PMON (Current) for SDH Equipment
PMON (History)
PMON (History)