The PASOLINK NEO system provides interface types of PDH, SDH and LAN. The
transmission signals are 5 to 48 x E1, 1 to 2 x E3, 1 to 2 x STM-1, 2/4 x 10/100 Base-T(X)
and GbE signals.
The systems consist of antennas, outdoor unit (ODU) and Indoor unit (IDU) same as PASOLINK series.
They are connected through a coaxial cable for each radio channel. Available configurations are non
protected type (1+0) and protected type (1+1). The protected type is available for twin-path type and
hot-standby type.
System Composition
• 1- Indoor unit (IDU) ( Modulation-Demodulation unit)
• 2- Outdoor unit (ODU) ( Transmit – Receive unit)
• 3- IF cable and connectors ( To connect the IDU & ODU)
• 4- Antenna on the required microwave band
• 5- Hybrid ( coupler ) in case of 1+1 one antenna configuration
• 6- RF cable ( If the ODU is not direct mounted to the antenna)
Antenna
Antenna IF
IF
IDU
IDU
System Configuration
A- Non protected system (1+0)
TX RX
IDU
ODU IDU
( 1+0 ) RX TX ODU
( 1+0 )
• High System Gain achieved by each modulation with Forward Error Correction
(FEC) Technology and distortion canceling technique called linearizer.
• High spectrum efficiency achieved by QPSK to 128QAM selectable technology.
• Allowing smaller antennas and reducing system cost.
• IDU - ODU Interconnection : Only one coaxial cable and automatic equalization.
• Very Compact and Light.
• Various mounting methods for IDU, ODU and Antenna.
• Easy Antenna direction adjustment.
Equipment Features
4. Frequency Agility and Easy Tuning
5. System Flexibility
6. Maintenance Facilities
• SV Channel commonality:
SV Commonality
Baseband Interface Flexibility
5/10/16E1 + 2Ether
4Ether + 4E1
ODU
Bitrate Free
• 5/10/20/40/48E1
• STM-1 IDU
• STM-2(310MB)
Modulation Free Interface Board
• 4PSK,16/32/128QAM
40/48E1
STM-1(elec.) STM-1(opt.)
ODU 1+1
5E1Æ10E1Æ16E1
Upgrade Key New INTF ODU
+Upgrade Key
New MODEM New MODEM
New INTF ODU New ODU
+New ODU
+Upgrade Key
40E1Æ48E1
Upgrade Key New INTF
ODU ODU +Upgrade Key
ODU
Repeater
New IDU/ODU STM-1
V ODU +Upgrade Key
H
ODU
2xSTM-1/XPIC
Memory Card
APS (Automatic Protection Switching)
STM-1 OPT INTFC (W) Working Line STM-1 OPT INTFC (W)
STM-1 OPT INTFC (P) Protection Line STM-1 OPT INTFC (P)
STM-1 OPT INTFC (W) Working Line STM-1 OPT INTFC (W)
STM-1 OPT INTFC (P) Protection Line STM-1 OPT INTFC (P)
Cross Polarization Interference Canceller
(XPIC)
The transmission capacity of the existing STM-1 equipment can be improved up to
2xSTM-1 by adding one more IDU, ODU and XPIC cable kit and additional firmware.
OMT OMT
H H
IDU ODU 2 ODU 2 IDU
Switchover Control
• Switchover Modes:
1. Automatic Switchover:
Switching is automatically initiated if any failure or abnormality was detected in
the online section.
2. Manual Switchover:
The operator initiate this switchover by LCT or PNMT for the maintenance and
test purposes. The manual switching has two selection Manual or Forced
switchover.
• Switching Priority:
The switching priority is only applied under automatic switching control.
System Performance Parameters QPSK
Frequency
6 7-8 11 13 15 18 23 26 28 32 38 52
Band, ( GHz )
Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0- 51.4-
51.4-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0 52.6
N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR100 PBR120 PBR140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320 N/A
Output Power,
+29 +25 +25 +23 +24 +24 +23 +23 +22 +18 +3
dBm
0 to 10
Power Control 0 to 30 dB 0 to 25 dB
dB
Frequency
± 6 ppm
Stability
CS = 28 (27.5) MHz -84 -83 -83 -83.5 -83.5 -83.5 -83 -83 -81.5 -81.5 -78
14 (13.75) MHz -87 -86 -86 -86.5 -86.5 -86.5 -86 -86 -84.5 -84.5 -81
7 MHz -90 -89 -89 -89.5 -89.5 -89.5 -89 -89 -87.5 -87.5 -84
CS = 28 (27.5) MHz 113 108 108 106.5 107.5 107.5 106 106 103.5 99.5 81
14 (13.75) MHz 116 111 111 109.5 110.5 110.5 109 109 106.5 102.5 84
7 MHz 119 114 114 112.5 113.5 113.5 114 114 109.5 105.5 87
Maximum Input
-15 dBm (No Error)
Level dBm
Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0
N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR 100 PBR 120 PBR 140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320
Output Power, dBm +25 +21 +21 +21 +19 +19 +18 +18 +17 +13.5
CS = 28 (27.5) MHz - 77 -76 -76 -76.5 -76.5 -76.5 -76 -76 -74.5 -74.5
14 (13.75) MHz -80 -79 -79 -79.5 -79.5 -79.5 -79 -79 -77.5 -77.5
7 MHz -83 -82 -82 -82.5 -82.5 -82.5 -82 -82 -80.5 -80.5
3.5 MHz -86 -85 -85 -85.5 -85.5 -85.5 -85 -85 -83.5 -83.5
BER = 10-3 Above value with +1.5 dB
CS = 7 MHz 108 103 103.5 101.5 101.5 101.5 100 100 97.5 95
3.5 MHz 111 106 106.5 104.5 104.5 104.5 103 103 100.5 98
Maximum Input
-20 dBm for the BER less than 10-
10-3
Level dBm
Output Power,
+25 +21 +21 +21 +19 +19 +18 +18 +17 +14.5 -3
dBm
Power Control 0 to 30 dB 0 to 6 dB
Frequency
± 6 ppm
Stability
CS = 28 (27.5) MHz -75.5 -74.5 -74.5 -75 -75 -75 -74.5 -74.5 -73 -73 -69.5
Range 5.925-
5.925- 7.125-
7.125- 10.7-
10.7- 12.75-
12.75- 14.2-
14.2- 17.7-
17.7- 21.2-
21.2- 24.25-
24.25- 27.5-
27.5- 31.8-
31.8- 37.0-
37.0-
( GHz ) 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27.0 29.5 33.4 40.0
N Type or N Type or
RF Remote Mount PDR 70 PDR 84
PDR 100 PBR 120 PBR 140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320
Output Power, dBm +25 +25 +21 +21 +21 +19 +19 +18 +18 +17 +14.5
Maximum Input
-20 dBm for the BER less than 10-
10-3
Level dBm
Residual BER Less than 10-
10-12 at RSL = -30 dBm
IDU Performance Parameters(1/2)
No. Item SPECIFICATION
Usually Provided
Optionally provided
Base Band Interface
Item Parameters Panel Details Available Capacity
Main STM1-E STM1-E STM-1 Electrical (IEC 1.0/2.3 coaxial) 155 Mbps
Interface
STM1-O-S11 STM1-O-S11 STM-1 Optical S-1.1 (connector type LC) 155 Mbps
STM1-O-L11 STM1-O-L11 STM-1 Optical L-1.1 (connector type LC) 155 Mbps
SDH-2P-LAN SDH-2P-LAN 2 port 10/100 Base-T(X) 155 Mbps
SDH-GBE SDH-GBE 1000 Base-T (RJ-45) or 1000 Base-SX (LC) 155 Mbps
PDH-16E1 PDH-16E1 16E1 + 2 port LAN (D-sub 75/120 ohm selectable 10 - 80 Mbps
The MODEM provides the QPSK/16QAM/32QAM/128QAM Modulation and Demodulation for E1/E3 (PDH),
10/100 base-T (LAN), or STM-1 (SDH) data transmission in addition to the following main functions:
When the ODU which connected is not NEO connected to IDU NEO, it is recommended to install the optional
DC-DC CONV into the IDU.
The ODU will be shorten ODUs life or may be damaged if not used optional DC-DC CONV module.
CTRL Unit CALL Transmit the EOW calling to sound
the BUZZER in the opposite station
PROTECT Prevent service interruption in case
of CTRL module replacement.
RX LEV MONITOR
• The nominal power supply voltage is -48 V DC.
However, the range of the unit is able to fit for
Turn OFF the DC
power before removing
nominal voltages of +24 V by additional unit.
the IF cable • The weight of ODU is 3 Kg.
Frame Ground
Outdoor Unit ( ODU )
• The transmitter-receiver is designed to handle an 8-155 Mbps digital signal in the 6-52 GHz
bands. The equipment is designed to withstand severe weather conditions. To achieve high
system gain performance, quadrature phase-shift keying (QPSK) modulation is applied. And to
achieve high frequency efficiency performance, 16/32/128-quadrature amplitude modulation
(16/32/128QAM) is applied. This ODU can apply to each modulation.
• Advanced integrated circuit technology, e.g., MMIC and MIC, is applied to the entire RF circuit in
ODU.
Outdoor Unit
Hybrid Combiner
NEC has developed Hybrid Combiner/Divider over the full range of microwave frequencies for PASOLINK Series digital microwave
radio point-
point-to-
to-point fixed wireless systems. This Hybrid Combiner/Divider comprises
comprises directional coupler, antenna interface, radio
mounting interfaces and polarizers.
polarizers. The RF signal power received by the single polarized antenna is
is equally distributed and sent to
two outdoor units through the Hybrid Combiner/Divider for 1+1 protected
protected systems.
There are two types of NEC Hybrid Combiner/Divider, one is coaxial
coaxial cable connection type for 6/7/8 GHz Bands and the other is
WG connection type for 11 – 52 GHz Bands. NEC Hybrid Combiner/Divider is suited for Andrew or RFS Antenna, and all NEC
ODUs.
Antenna
(d)
(a) STM-1 near-end loopback (STM-1 LB1) at the 150M INTFC/OPT INTFC module
(b) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC module from LCT
(c) IF loopback (IF-LB) at the MODEM module (Local only)
(d) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC Module from PNMT/PNMS
•Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent
stations from the PNMS and PNMT are disabled.
PASOLINK NEO Installation
Before going to any site,
IFConnector
IF Connector&&Power
Power
Connectortermination
termination Confirm 19" Rack Location
Connector
& DC-Power Source
19"rack
19" rackfixing
fixing
FollowThe
Follow The
terminationProcedure
termination Procedure IDU
Mounting
RackEarthing
Rack Earthing
Connection
Connection
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection
IDUGrounding
IDU GroundingConnection
Connection
WALL
Power
Connector
Socket Contact
Power
Cable
1-Remove 3.0 to 3.5 mm of Insulation 1
2
2- Set the socket contact to the following
position onto the hand crimping tool
4- Cable should fit, so insulation and bare wire are arranged as shown,
5- Squeeze the handle of the hand crimping tool until ratchet is released.
5-Squeeze the
handle of the hand
crimping tool until
ratchet Is released
(0 V)
NESIC CAIRO
1-OUTDOOR
1-OUTDOOR Unpackingofof
Unpacking Unpacking
Unpacking Unpackingofof
INSTALLATION
INSTALLATION Accessories ofODU
ODU
Unpacking
Accessories of Antenna
Antenna
FLOWCHART
FLOW CHART
IFConnector
IF Connector Removethe
Remove theODU
ODU Antenna bracket
cover,Confirm
cover, Confirmthe
the assembling,
Polarity
Polarity Confirm the Polarity
FollowThe
Follow The
terminationProcedure
termination Procedure ODU
Mounting Refer to the Antenna
assembling guide
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection
ODUGrounding
ODU GroundingConnection
Connection
New Type Bracket for 11-38 GHz Band ODU Old Type Bracket for 11-38 GHz Band ODU
POLE MOUNTING BRACKET
SCREWS
SCREWS
H - POLARIZATION ANTENNA
CONNECTION
UNIT
•When vertical polarization is required, rotate the •When horizontal polarization is required, rotate the
IDU so that the plate marked with V is pointing up. IDU so that the plate marked with H is pointing up.
Fix the ODU in this position Fix the ODU in this position
USE OF O-RINGS
Hardware Requirement:
Software Requirement:
Enter URL Address: http://172.17.254.253 of the IE and press the “Enter” key.
The login window will then enter your login information User ID and password in the entry field then
press login
For QPSK
For 16QAM
For 32QAM
Equipment Setup (3/3)
ODU FREQ. INFO
• Select “Open” or “Close” to apply to the output mode to apply for event output.
• From INPUT3 to INPUT6 can be assigned as Input Cluster Alarm Cluster IN1 to
Cluster IN4.
ATPC MODE
MTPC MODE
Provisioning (3/4) SDH Provisioning
Assignable
For RS-232C-1 or -2
Assignable
For V.11-1 or -2
ATPC MODE
MTPC MODE
Provisioning (4/4)
Provisioning
Metering
PMON (Current) for PDH Equipment
PMON (History)
PMON (History)
PMON (Current) for SDH Equipment
PMON (History)
PMON (History)
NESIC CAIRO
International Training Center