SMART Digital XL
DIGITAL DOSING from 60 to 200 l/h
DDA, DDE
Pumps and accessories
SMART Digital XL
1. General data 3
Table of contents
Performance range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features at a glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. Identification 6
3. Functions overview 7
Overview of functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4. Functions DDA 9
Operating elements DDA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operation modes DDA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Functions DDA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring diagram, DDA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5. Functions DDE 19
Operating elements DDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Operation modes DDE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Functions DDE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Wiring diagram, DDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6. Construction 23
DDA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7. Dimensions 25
8. Technical data 26
DDA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9. Pump selection 28
DDA, standard range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
DDE, standard range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DDA, DDE, non-standard range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2
SMART Digital XL
1
1. General data
General data
Performance range
3
1 SMART Digital XL
4
SMART Digital XL
1
Two application-oriented type ranges
General data
DDA is the high-end pump range for extended flow and
pressure ranges with sensor-based FlowControl and
measurement functions for challenging industrial
applications, such as:
• Drinking water treatment
• Wastewater treatment
• Boiler water treatment
• Cooling water treatment
• Process water treatment
• Chemical industry
• Ultrafiltration process and reverse osmosis
• Food and beverage industry
• Paper and pulp industry.
5
2 SMART Digital XL
2. Identification
Identification
Control cube
DDA 60-10 FCM-PVC/V/C-F-31U3U3FG
F Front mounted (change to left or right is possible)
Supply voltage
DDA 60-10 FCM-PVC/V/C-F-31U3U3FG
3 100-240 V 50/60 Hz single phase
Valve type
DDA 60-10 FCM-PVC/V/C-F-31U3U3FG
1 Standard
2 Spring-loaded
6
SMART Digital XL
3
3. Functions overview
Functions overview
Overview of functions
DDA DDE
General
Digital Dosing: Internal stroke speed control and frequency control ● ● ● ●
Mounting plate ● ● ● ●
Control panel, see page 9 and 19
Control cube mountable in three positions: front, left, right ● ● ● ●
Transparent protective cover for control elements ● ● ● ●
Capacity setting in millilitres, litres or US-gallons ● ●
Graphical display with background light in four colours for status indication: white, green, yellow, red ● ●
LEDs for operation mode, warning and alarm ● ●
Plain-text menu in different languages ● ●
Turn-and-push knob (click wheel) for easy navigation ● ●
Capacity adjusting knob (0.125 - 100 %) ● ●
Start/Stop key ● ●
100 % key (deaearation) ● ● ●
Operation mode key (manual/pulse/analog) ●
Operation modes, see page 10 and 20
Manual speed control ● ● ● ●
Pulse control in ml/pulse ● ●
Pulse control (1:n) ●
Analog control 4-20 mA ●
Analog control 0/4-20 mA ● ●
Batch control (pulse-based) ● ●
Dosing timer cycle ● ●
Dosing timer week ● ●
Fieldbus control ● ●
Functions, see page 12 and 21
Auto deaeration also during pump standby ● ●
FlowControl system with selective fault diagnosis ●
Pressure monitoring (min/max) ●
Flow measurement ●
AutoFlowAdapt ●
Stop after power failure ● ●
SlowMode (anti-cavitation) ● ●
Calibration mode ● ●
Full scaling of analog input ● ●
Scaling of maximum analog input ●
Service information display ● ●
Relay setting: alarm, warning, stroke signal, pump dosing, pulse input* ● ● ●
Relay setting (additionally): timer cycle, timer week ● ●
Inputs/outputs, see page 12 and 21
Input for external stop ● ● ●
Input for pulse control ● ● ●
Input for analog 4-20 mA control ●
Input for analog 0/4-20 mA control ● ●
Input for low-level signal ● ● ●
Input for empty tank signal ● ● ●
Output relay (2 relays) ● ● ●
Output analog 0/4-20 mA ● ●
Input/Output for GENIbus ● ●
Input for software update ● ● ● ●
Input/Output for CIU (Profibus DP, Modbus, GRM, Ethernet etc.) ● ●
* DDE-AR: relay 1: alarm; relay 2: low-level signal, stroke signal, pulse input
7
3 SMART Digital XL
Functional description
Functions overview
Capacity SlowMode
setting
Discharge
100 % -
Duration
Suction
Discharge
50 % - Duration
Suction
Discharge
10 % -
Duration
Discharge
10 % 50 % Duration
8
SMART Digital XL
4
4. Functions DDA
Functions DDA
Operating elements DDA Menu
The DDA dosing pumps feature a user-friendly
The pump is supplied with front-mounted control cube.
plain-text menu. The menu consists of 4 tabs:
The position of the control cube can easily be changed
by unfastening two screws, lifting the cube, turning it to • Operation
the left or to the right and fastening both screws again. • Info
• Alarm
• Setup.
During initial startup, all menu text appears in the
English language. The menu can be set to display
other languages.
Info
1
Th 16.02.2017 12:34
Operation
Counter >
60.0 l/h Service -
Manual 60.0 l/h Service kit
3
.............................
2 4
Alarm
TM06 7334 3316
1 16.02.2017 15:10
Low level
2 15.02.2017 14:34
Empty
The click wheel guides the user quickly and easily The menu text appears in up to 28 languages on a big
through the plain-text menu. graphical display, backlit in four different colours
If the maximum capacity is required over a short period according to the traffic light concept.
of time, for example during startup, press the [100%]
Display Fault Pump status
key. To set the pump to run for a specific number of
seconds at maximum capacity, press the [100%] key White - Stop Standby
Green - Running
and turn the click wheel clockwise simultaneously.
Yellow Warning Stop Standby Running
Red Alarm Stop Standby
9
4 SMART Digital XL
10
SMART Digital XL
4
Pulse-based batch control Dosing timer week
Functions DDA
The set quantity is dosed in batches within the The integrated real-time clock features also
set dosing time (t1). A batch is dosed every time the batch dosing based on a weekly period. There is a
pump receives an external pulse. If the pump receives maximum of 16 procedures per week. Each dosing
new pulses before a batch is completed, these pulses procedure consists of:
will be ignored. In the event of interrupts such as • Batch volume
external stop or alarm, incoming pulses will also be • Dosing time
ignored. After ending of the interrupts, a new batch will
• Start time
be dosed with the next incoming pulse.
• 1 to 7 weekdays (Monday to Sunday).
Batch volume In case several procedures are overlapping, the
procedure with the highest flow rate has the highest
priority. Batch dosing is stopped during any interrupt,
e.g. power supply failure or external stop, while the
t1 t1 time continues running in the background (real-time
Setting range 1 1 1 1
6:00
4 4
Setting range
Pump type
From [ml/batch] To [l/batch] Resolution [ml]* 12:00
DDA 60-10 5.56 999 0.694 2 2
Batch volume
t1 t1
Time
TM06 7089 3918
t2
t3
Setting range
The batch volume setting range corresponds to the
pulse-based batch control setting range.
11
4 SMART Digital XL
12
SMART Digital XL
4
Service display Relay output
Functions DDA
Due to the optimised construction and the The pump can switch two external signals using
smooth digital dosing principle, the service periods are installed relays. The relay outputs are potential-free.
more than twice as long, if compared to conventional Depending on the process control requirements, the
pumps. However, the wear parts have to be exchanged following relay output settings can be chosen:
in regular intervals in order to keep the dosing
precision and the process reliability at a high level. The Signal
Description
service display in the pump shows when service of the Relay 1 Relay 2
wear parts is required. The displayed service kit Display red, pump stopped (e.g.
Alarm* Alarm
product number makes service more convenient. The empty tank signal, etc.)
following information is displayed in the Info Display yellow, pump running (low
Warning* Warning
level signal, etc.)
display:
Stroke signal** Stroke signal** Every completed stroke
Display Description Pump dosing Pump dosing* Pump is running and dosing
Every pulse coming in from pulse
- No service required Pulse input*** Pulse input***
input
Service Soon Order parts for service soon Set by a command in the Bus
Now Service must be performed now Bus control Bus control
communication function (page 14)
The service kit contains all parts Timer can be set in menu: on-time,
8-digit Grundfos Timer cycle
Service kit needed for standard maintenance: cycle-time, start delay
product number
diaphragm + valves Timer can be set in menu:
After performing the service, reset Timer week procedure, on-time, start time and
Reset service system
the system weekdays
13
4 SMART Digital XL
The pump can be connected to a Grundfos CIU The additional display function provides further useful
unit (Communication Interface Unit) equipped with one status information, e.g. the target flow rate as well as
of the following CIM modules (Communication the actual flow rate. The value is shown in the
Interface Module): operation display together with the corresponding
• CIM150 Profibus symbol.
• CIM200 Modbus
• CIM260 3G/4G/SMS Operation
• CIM280 3G/4G/GRM/GIC
• CIM500 Ethernet. 60.0 l/h
Manual 59.9 l/h
For internal communication between the CIU and the
Units
It is possible to select metric units (litre/millilitre/bar) or
US units (US gallons/psi). Depending on the operation
mode and menu, the following units are displayed:
Operation mode/Function Metric units US units
Manual control ml/h or l/h gph
Pulse control ml/ ml/
Analog 0/4-20 mA control ml/h or l/h gph
Batch control (pulse- or
ml or l gal
timer-based)
Calibration ml ml
Volume counter l gal
Pressure monitoring bar psi
14
SMART Digital XL
4
Diaphragm leakage detection (DLD)
Functions DDA
Applies to DDA-AR control variant
Pumps with diaphragm leakage detection (DLD) have
a special dosing head with a special diaphragm and a
pressure switch. The pressure switch is fitted and
connected to the pump on delivery.
For pumps with diaphragm leakage detection the
pressure differential between inlet and outlet side must
be at least 2 bar / 29 psi.
3 D1 D2 D3
Fig. 15 Diaphragm leakage detection
Pos. Components
1 Pressure switch
2 Dosing head
3 Drain opening
4 Dosing medium
D1 Working diaphragm
D2 Signal diaphragm (intermediate layer)
D3 Protective diaphragm
15
4 SMART Digital XL
Pressure
1
3 TM04 1610 1710
Stroke length
1 Compression phase
2 Discharge phase
3 Expansion phase
4 Suction phase
16
SMART Digital XL
4
Pressure monitoring AutoFlowAdapt
Functions DDA
Applies to DDA-FCM control variant Applies to DDA-FCM control variant
The integrated pressure sensor measures the actual When activating the AutoFlowAdapt function even
pressure of the system, which is shown in the display. environmental changes will be compensated, so that
A maximum pressure can be set. If the pressure in the the required target flow rate will be achieved. The
system exceeds the set maximum (e.g. caused by a integrated AutoFlowAdapt makes additional monitoring
closed valve), the pressure monitoring function stops and control devices redundant. The AutoFlowAdapt
the dosing process immediately. As soon as the function is based on:
backpressure falls below the set maximum, the dosing • FlowControl: malfunctions are detected
process is continued. In case the pressure drops below • Pressure monitoring: system pressure changes are
the minimum limit (e.g. caused by a burst outlet line) detected
the pump stops and major chemical spills are
• Flow measurement: deviations in the target flow are
prevented.
detected.
Pressure setting range
Examples:
Pump type
Fixed min. pressure Adjustable max. pressure • FlowControl detects air bubbles in the system. Due
[bar]* [bar]**
to a special motor drive strategy and a certain
DDA 60-10 2 3 ... 11 (default) speed increase, the pump will try to keep the flow
DDA 120-7 2 3 ... 8 (default)
rate constant. This is especially important when
DDA 200-4 2 3 ... 5 (default)
dosing degassing liquids.
* Can be either set as a warning (pump keeps running) or as an • In general, increasing system pressure reduces the
alarm (pump stops)
** The adjustable max. pressure is equivalent to the max. operating stroke volume whereas falling system pressure
pressure plus 1 bar increases the stroke volume. The AutoFlowAdapt
function compensates this by automatically and
Flow measurement continuously adapting the motor speed. Despite
Applies to DDA-FCM control variant fluctuating system pressure, dosing accuracy is
The pump can precisely measure and display the maintained.
actual dosing flow. Via the analog 0/4-20 mA output,
the actual flow signal can easily be integrated in any
process control system, without needing any additional
measurement equipment.
The Flow measurement function is based on an
indicator diagram as described in FlowControl (page
16). Accumulating the length of each discharge stroke
phase and multiplying it with the stroke frequency
results in the displayed actual flow. Any malfunctions,
such as air bubbles or lower backpressure, will result
in a reduced or increased actual flow rate. When the
AutoFlowAdapt function (page 17) is activated, the
pump compensates these influences by correcting the
stroke speed.
17
4 SMART Digital XL
2 1 2 1
3 4 3 4
2 1 2 1
5 5
3 4 3 4
4 3
1 2
Product number
Symbol Function Pin assignment
2 m cable 3 m cable 5 m cable
1/brown 2/white 3/blue 4/black
Analog GND/(-) mA (+) mA
96609014 96609016
External stop GND X
Pulse GND X
1 2 3 4
Low-level signal X GND see page 35, suction lances
Empty signal X GND
5/yellow/
1/brown 2/white 3/blue 4/black
green 96632921 96632922
Analog output (+) mA GND/(-) mA
1 2/brown 3/blue 4 5/black
98589048
GENIbus RS-485 A RS-485 B GND
1/brown 2/white 3/blue 4/black
Relay 1 X X 96609017 96609019
Relay 2 X X
18
SMART Digital XL
5
5. Functions DDE
Functions DDE
Operating elements DDE LEDs (DDE-B)
The LEDs indicate the following operating statuses
The pump is supplied with front-mounted control cube.
and faults:
The position of the control cube can easily be changed
by unfastening two screws, lifting the cube, turning it to LED status
Pump status Description
the left or to the right and fastening both screws again.
● running
❍ standby Capacity adjusted to 0 %
Motor blocked or
❍ stop
overheated
● = LED on
LED status
Pump status Description
9
TM06 7320 3316
● running
❍ standby Capacity adjusted to 0 %
● running
❍ standby No incoming pulses
Fig. 21 Operating elements DDE ● running
❍ standby Analog signal < 4.1 mA
Control ❍ ● running Low-level in tank
Pos. Description variant ● ❍ stop Tank empty
B AR ● ❍ standby External stop activated
❍ stop Motor blocked or overheated
Status LEDs
Motor blockage (red) ● ● ● = LED on
1
External stop (red) ● ❍ = LED flashing
Empty table cell = LED off
2 Tank level (yellow) ●
3 [Operation mode] key ●
Operation mode LEDs (green):
4 Pulse ●
5 Manual ● ●
6 Analog ●
7 Logarithmic scale ● ●
8 Capacity adjusting knob ● ●
9 [100%] key ●
19
5 SMART Digital XL
20
SMART Digital XL
5
Functions DDE Relay output
Functions DDE
Applies to DDE-AR control variant
External stop The pump can switch two external signals using
Applies to DDE-AR control variant installed relays. The relay outputs are potential-free.
With the external stop function, the pump can be Depending on the process control requirements, the
stopped from a remote place via an external contact. It following relay output settings can be chosen:
is not recommended to switch on and off the power
Signal
supply as it was usual when working with a Description
conventional dosing pump. When working with Relay 1 Relay 2
microprocessor-controlled digital dosing pumps, the Alarm* Empty tank, motor blocked
external stop signal has to be used, in order to keep Low level* Low level tank
the optimal dosing precision and to prevent damages Stroke signal Every completed stroke
Pulse input Every pulse coming in from pulse input
to the electronics.
Contact type
When activating the external stop signal, the pump
NO* NO* Normally Open Contact
changes from running to standby . The signal
NC NC Normally Closed Contact
input can be set to normally open (default) or normally
closed contact. * default setting
Level control
Applies to DDE-AR control variant
The pump can be connected to a dual level control unit
for monitoring of the chemical level in the tank. The
pump can react to two level signals:
Level sensors Pump reaction*
• LED flashes
Low-level signal
• Pump continues running
• LED on
Empty tank signal
• Pump stops
* Depending on the pump model and settings, the relay outputs can
be activated (see Relay output, page 21).
21
5 SMART Digital XL
2 1 2 1
3 4 3 4
2 1
5
3 4
4 3
1 2
Product number
Symbol Function Pin assignment
2 m cable 5 m cable
1/brown 2/white 3/blue 4/black
Analog GND/(-) mA (+) mA
96609014 96609016
External stop GND X
Pulse GND X
1 2 3 4
Low-level signal X GND see page 35, suction lances
Empty signal X GND
22
SMART Digital XL
6
6. Construction
Construction
DDA
13 14 15 16 17 18 19 20 21 22 23 24
12
25
11
10
9 26
8
7
6
5
27
3
23
6 SMART Digital XL
DDE
Construction
11 12 13 14 15 16 17 18 19 20 21 22
10
23
24
8
6
5
4
25
26
1
24
SMART Digital XL
7
7. Dimensions
Dimensions
29 187 4xØ9
36 140 4xØ7
105
136
180
7
10 Ø7
159
13 172.5
183.5
140.5 A
A2 A1
G 5/4"
283.5
B
25
194
A A1 A2* B C D
Pump type Pump head material
[mm] [mm] [mm] [mm] [mm] [mm]
DDA 60-10 PVC/PV 410 374 26 263 112 45
DDE 60-10 SS 405 364 - 263 112 45
DDA 120-7 PVC/PV 410 374 26 276.5 97 45
DDE 120-7 SS 405 364 - 276.5 97 45
DDA 200-4 PVC/PV 410 374 26 287.5 88 45
DDE 200-4 SS 405 364 - 287.5 88 45
* Dimension with optional diaphragm leakage detection. Only available for DDA-AR control variant.
25
8 SMART Digital XL
8. Technical data
Technical data
DDA
Data 60-10 120-7 200-4
Turn-down ratio (setting range) [1:X] 800 800 800
[l/h] 60 120 200
Max. dosing capacity
[gph] 15.8 32 52.8
[l/h] 30 60 100
Max. dosing capacity with SlowMode 50 %
[gph] 7.9 16 26.4
[l/h] 15 30 50
Max. dosing capacity with SlowMode 25 %
[gph] 3.95 8 13.2
[l/h] 0.075 0.15 0.25
Min. dosing capacity
[gph] 0.0197 0.04 0.066
[bar] 10 7 4
Max. operating pressure (backpressure)
[psi] 145 101 58
Max. stroke frequency 1) [strokes/min] 196 188 188
Stroke volume [ml] 5.56 11.58 19.3
Accuracy of repeatability 5) [%] 1.5 SP + 0.1 FS 5)
Max. suction lift during operation 2) [m] 3
Max. suction lift when priming with wet valves2) [m] 1.5
Mechanical data [bar] 1 6)
Min. pressure difference between inlet and outlet side
[psi] 14.5 6)
[bar] 2
Max. inlet pressure, inlet side
[psi] 29
Max. viscosity in SlowMode 25 % with spring-loaded valves 3) [mPas] (= cP) 3000 3000 2000
Max. viscosity in SlowMode 50 % with spring-loaded valves 3) [mPas] (= cP) 2000 1500 1000
Max. viscosity without SlowMode with spring-loaded valves 3) [mPas] (= cP) 1000 1000 500
Max. viscosity without spring-loaded valves 3) [mPas] (= cP) 100
Min. internal hose/pipe diameter inlet/outlet side 2), 4) [mm] 19
Min. internal hose/pipe diameter inlet/outlet side (high viscosity)4) [mm] 19
Min. / Max. liquid temperature (PVDF, SS) [°C] 0/50
Min. / Max. liquid temperature (PVC) [°C] 0/40
Min. / Max. ambient temperature [°C] 0/45
Min. / Max. storage temperature (PVDF, SS) [°C] -20/70
Min. / Max. storage temperature (PVC) [°C] -20/45
Max. relative humidity (non-condensing) [%] 90
Max. altitude above sea level [m] 2000
Voltage [V] 100-240 V ± 10 %, 50/60 Hz
Length of mains cable [m] 1.5
Max. inrush current for 2 ms (100 V) [A] 35
Max. inrush current for 2 ms (240 V) [A] 70
Electrical data
Max. power consumption P1 [W] 62
Enclosure class IP65, Nema 4X
Electrical safety class I
Pollution degree 2
Max. load for level input, pulse input and External stop input 12 V, 5 mA
Min. pulse length [ms] 5
Max. pulse frequency [Hz] 100
Signal input Impedance at 0/4-20 mA analog input [Ω] 15
Accuracy of analog input (full-scale value) [%] ± 0.5
Min. resolution of analog input [mA] 0.02
Max. loop resistance in external circuit [Ω] 150
Max. resistive load on relay output [A] 0.5
Max. voltage on relay/analog output [V] 30 VDC / 30 VAC
Signal output Max. loop resistance in external circuit of the 0/4-20 mA analog output [Ω] 500
Accuracy of analog output (full-scale value) [%] ± 0.5
Min. resolution of analog output [mA] 0.02
Weight (PVC, PVDF) [kg] 6.7 7.9 8.9
Weight/size Weight (stainless steel) [kg] 7.2 8.3 9.1
Diaphragm diameter [mm] 74 97 117
Sound pressure Max. sound pressure level [dB(A)] 80
26
SMART Digital XL
8
DDE
Technical data
Data 60-10 120-7 200-4
Turn-down ratio (setting range) [1:X] 800 800 800
[l/h] 60 120 200
Max. dosing capacity
[gph] 15.8 32 52.8
[l/h] 0.075 0.15 0.25
Min. dosing capacity
[gph] 0.0197 0.04 0.066
[bar] 10 7 4
Max. operating pressure
[psi] 145 101 58
Max. stroke frequency [strokes/min] 196 188 188
Stroke volume [ml] 5.56 11.58 19.3
Accuracy of repeatability 4) [%] 5 SP + 0.1 FS
Max. suction lift during operation 1) [m] 3
Max. suction lift when priming with wet valves1) [m] 1.5
[bar] 1
Mechanical Min. pressure difference between inlet and outlet side
[psi] 14.5
data
[bar] 2
Max. inlet pressure, inlet side
[psi] 29
Max. viscosity with spring-loaded valves 2) [mPas] (= cP) 1000 1000 500
Max. viscosity without spring-loaded valves2) [mPas] (= cP) 100
Min. internal hose/pipe diameter inlet/outlet side1), 3) [mm] 19
Min. internal hose/pipe diameter inlet/outlet side (high viscosity) 3) [mm] 19
Min. / Max. liquid temperature (PVDF, SS) [°C] 0/50
Min. / Max. liquid temperature (PVC) [°C] 0/40
Min. / Max. ambient temperature [°C] 0/45
Min. / Max. storage temperature (PVDF, SS) [°C] -20/70
Min. / Max. storage temperature (PVC) [°C] -20/45
Max. relative humidity (non-condensing) [%] 90
Max. altitude above sea level [m] 2000
Voltage [V] 100-240 V ± 10 %, 50/60 Hz
Length of mains cable [m] 1.5
Max. inrush current for 2 ms (100 V) [A] 35
Electrical Max. inrush current for 2 ms (240 V) [A] 70
data Max. power consumption P1 [W] 62
Enclosure class IP65, Nema 4X
Electrical safety class I
Pollution degree 2
Max. load for level input, pulse input and External stop input 12 V, 5 mA
Min. pulse length [ms] 5
Max. pulse frequency [Hz] 100
Signal input Max. loop resistance in external circuit [Ω] 150
Impedance at 4-20 mA analog input [Ω] 15
Accuracy of analog input (full-scale value) [%] ± 0.5
Min. resolution of analog input [mA] 0.02
Signal Max. resistive load on relay output [A] 0.5
output Max. voltage on relay output [V] 30 VDC / 30 VAC
Weight (PVC, PVDF) [kg] 6.7 7.9 8.9
Weight/size Weight (stainless steel) [kg] 7.2 8.3 9.1
Diaphragm diameter [mm] 74 97 117
Sound
Max. sound pressure level [dB(A)] 80
pressure
1) Data is based on measurements with water 3) Length of inlet line: 1.5 m, length of outlet line: 10 m (at max.
2)
Maximum suction lift: 1 m, dosing capacity reduced (approx. 30 %) viscosity)
4) FS = Full-scale, SP = Setpoint
The dosing head material Polyvinyl chloride (PVC) must not be used in CIP applications.
27
9 SMART Digital XL
9. Pump selection
Pump selection
Valves: Standard
U3U3: 2x union nut G 5/4", 2x hose connector 19/20 mm, 2x hose clamp, 2x pipe connector 25 mm
Connection sets:
A1A1: 2x union nut G 5/4" (SS), 2x inlay internal thread Rp 3/4" (SS)
28
SMART Digital XL
9
DDE, standard range
Pump selection
Supply voltage: 100-240 V, 50/60 Hz single phase
Valves: Standard
U3U3: 2x union nut G 5/4", 2x hose connector 19/20 mm, 2x hose clamp, 2x pipe connector 25 mm
Connection sets:
A1A1: 2x union nut G 5/4" (SS), 2x inlay internal thread Rp 3/4" (SS)
29
9 SMART Digital XL
The codes used in the following tables are explained in the type key. See page 6.
DDA
Materials Control
Max. flow Control DLD Supply Valve Connection Mains Special
cube Design
- press. variant function Head Gaskets Balls voltage type inlet / outlet plug variant
position
E
PVC 1 U3U3
V C F 3
PV 2 A7A7
T
NO
E
1 A1A1
SS V SS F 3
2 A3A3
T
AR F
E
PVC-L 1 U3U3 B
V C F 3
60-10 PV-L 2 A7A7 G
T
120-7 YES I G C3
200-4 E E
1 A1A1
SS-L V SS F 3 J
2 A3A3
T L
E
PVC 1 U3U3
V C F 3
PV 2 A7A7
T
FCM NO
E
1 A1A1
SS V SS F 3
2 A3A3
T
DDE
Materials Control
Max. flow Control DLD Supply Valve Connection Mains Special
cube Design
- press. variant function Head Gaskets Balls voltage type inlet / outlet plug variant
position
E F
PVC 1 U3U3
V C F 3 B
PV 2 A7A7
60-10 T G
B
120-7 NO I G C3
AR E
200-4 1 A1A1 E
SS V SS F 3 J
2 A3A3
T L
30
Accessories for dosing pumps
10
Accessories overview
Pulsation dampers,
see page 43
Pressure valves,
see page 42
Foot valves and rigid suction lances, see page 34 and page 35
TM06 8374 0317
31
10 Accessories for dosing pumps
Fig. 26 Cable and plug for DDA, DDE, DMX, DMH and
DDI pumps
Technical data
• Cable material: PVC, 0.34 mm2
• Plug size: M 12
Socket for Socket for DMX, Cable length Product
Application Pins Plug type
DDA and DDE DMH and DDI [m] number
2 96609014
Analog pulse Straight 5 96609016
4 Input
External stop
4
No cable 96698715
Angled 2 96693246
2 96609017
Relay 1 Straight 5 96609019
3 Output
Relay 2
4
No cable 96696198
Angled 2 96698716
2 96632921
Straight 5 96632922
2 Output Analog 5
No cable 96609031
Angled 2 96699697
Low-level
5 DDI
Empty tank
4 Straight - 96698715
- 6 DDI
Profibus
Terminating
resistor
- 96693737
32
Accessories for dosing pumps
10
Hoses
Technical data
33
10 Accessories for dosing pumps
Foot valves FV
Accessories for medium-sized dosing pumps up to 460 l/h
Foot valves are installed at the lower end of the inlet Dimensions
hose. They have no level indication.
Foot valves include: d
L d
Material
[mm] [mm]
PE/PVDF 57 53
SS 57 50
Technical data
34
Accessories for dosing pumps
10
Rigid suction lances RSL
D
the inlet hose. They are available either without level
indication or with low-level and empty-tank indication.
Their immersion depth is adjustable.
B
Rigid suction lances include:
C
• Strainer (mesh size approx. 2.2 mm)
• Non-return valve
• Hose and pipe connection set:
– for hoses with internal diameter 19 or 20 mm ØF
– for PVC pipes with external diameter 25 mm E
• Adjustable tank connection with holes for a
deaeration line.
A
Rigid suction lances with low-level and empty-tank
indication include additionally:
H
• M 12 plug to connect DDA, DDE, DME or DDI
dosing pumps.
The contact type of the low-level and empty-tank Fig. 30 Rigid suction lances
indication is factory-set to NO. The contact type can be
set to NC by turning the floaters upside down. A B C D E ∅F G* H* I
[mm] [mm] [mm] [inch] [inch] [mm] [mm] [mm] [mm]
Electrical data of the level indication:
500
• Max. voltage: 48 V 690
159 140 G 5/4 G2 40 138 34 8.7
• Max. current: 0.5 A 980
1200
• Max. load: 10 VA
* Switching level for water
Dimensions / Selection
Recommended
Tank volume
For dosing tank type immersion depth (A)
[l]
[mm]
60 500
100 690
200 690
Grundfos cylindrical tank
300 980
500 1200
1000 1200
TM06 8423 0517
Technical data
35
10 Accessories for dosing pumps
Technical data
Counter nut for tanks without threaded opening, e.g. 100-litre square tank or
PVC, grey 98071170
1000-litre cylindrical tank
IBC (Intermediate Bulk Container) with opening of ∅150 mm, S 160 x 7 PE, black 98071177
36
Accessories for dosing pumps
10
Emission protection kits M 12-plug-to-flat-plug adapter
A
B
TM06 8372 0317
Position Description
A Gasket for the cable outlet
B Air valve
C Gasket for the tank adapter
Order data
37
10 Accessories for dosing pumps
Level-control units
Accessories for medium-sized dosing pumps up to 460 l/h
F *
(
E
'
$
TM06 8304 5116
ØC
Fig. 34 Flexible level-control unit
B
ØA ∅A B C D E F ∅G H I J
[mm] [mm] [mm] [mm] [mm] [inch] [mm] [mm] [mm] [mm]
Fig. 33 Level-control unit for electric stirrer protection
35 19 43.5 103.5 196 G 5/8 58 6 9 12
∅A B ∅C D E Technical data
F
[mm] [mm] [mm] [mm] [mm]
40 47.5 32 20 182 M 12 x 1.5 Product
Description Material
number
32 43 32 28 190 M 12 x 1.5
Flexible level-control unit PE 98375695
38
Accessories for dosing pumps
10
Injection units
Dimensions
ØD
E
A
Wrench size
A B C ∅D
E
[inch] [mm] [mm] [mm]
C [mm]
B G1 330 120 25 50
E
A
39
10 Accessories for dosing pumps
A
tank.
• Relief pressure, adjustable from 3 to 10 bar, is
factory-set to 10 bar
G
• Maximum operating pressure 10 bar
B
G
• Hose and pipe connection set (PVC, PP, PVDF):
J
– for hoses with internal diameter 19 or 20 mm K
– for pipes with external diameter 25 mm C
• Pipe connection set (stainless steel): threaded, Rp ØF
3/4", internal thread. Fig. 40 Pressure relief valve, stainless steel version
A B C ∅F G J K
D
[mm] [mm] [mm] [mm] [inch] [mm] [mm]
167 30 63 M6 89 Rp 3/4 10 17.5
Technical data
FKM/EPDM 99131032
PVC
PTFE 99141139
PP FKM/EPDM 99141197
460
FKM/EPDM 99141212
PVDF
PTFE 99141224
Fig. 38 Pressure relief valve SS * - 99141228
* SS 1.4571
Dimensions
A
G
B
C
D
H
ØF
A B C D E ∅F G H I
[mm] [mm] [mm] [mm] [mm] [mm] [inch] [mm] [mm]
168 30 92 6.5 150 85 G 5/4 40 75
40
Accessories for dosing pumps
10
Pressure loading valves PLV
A
pulsation damper
• To prevent syphoning, when the inlet pressure is
higher than the counterpressure
G
B
Pressure loading valves are installed in the outlet line
after the pressure relief valve, and after the pulsation
E
damper, if fitted.
• Opening pressure, adjustable from 3 to 10 bar, is
factory-set to 3 bar
• Maximum operating pressure: 10 bar C
• Hose and pipe connection set (PVC, PP, PVDF): D
ØF
– for pipes with external diameter 25 mm
H
• Pipe connection set (stainless steel): threaded, Rp
3/4", internal thread
Pressure loading valves must not be used as shut-off Fig. 42 Pressure loading valve (PP, PVC, PVDF version)
valves.
A B C D E ∅F G H
[mm] [mm] [mm] [mm] [mm] [mm] [inch] [mm]
168 30 92 6.5 150 85 G 5/4 40
TM06 8422 0517
K
C
ØF
A B C ∅F G J K
D
[mm] [mm] [mm] [mm] [inch] [mm] [mm]
167 30 63 M6 89 Rp 3/4 10 17.5
Technical data
FKM/EPDM 99132186
PVC
PTFE 99140593
PP FKM/EPDM 99140610
460
FKM/EPDM 99140646
PVDF
PTFE 99140651
SS * - 99135772
* SS 1.4571
41
10 Accessories for dosing pumps
Pressure valves PV
Accessories for medium-sized dosing pumps up to 460 l/h
B
A
A B
Material
[mm] [inch]
PVC
94 G 5/4
PVDF
SS 100 G 5/4
Technical data
42
Accessories for dosing pumps
10
Pulsation dampers and calibration columns
43
10 Accessories for dosing pumps
Sizing guide for pulsation dampers DB, DBG, CSD and calibration columns
Accessories for medium-sized dosing pumps up to 460 l/h
Look up your pump type in the table. Find the required pulsation damper or calibration column volume in the
respective table column.
Required damper Required Required damper Required
Pump Pump
volume calibration volume calibration
stroke stroke
Pump types column Pump types column
volume volume DB/DBG CSD
DB/DBG CSD volume volume
[ml] [ml] [l] [l]
[l] [l] [l] [l]
44
Accessories for dosing pumps
10
Suction-side pulsation dampers CSD with calibration scale
E
or socket (d).
• Calibration is possible by installing a T-piece and a
shut-off valve.
• In installations without flooded suction, the optional
manual vacuum pump kit simplifies the startup of
the dosing pump. See Manual vacuum pump kit on
page 46.
B
Pulsation dampers CSD include:
C
• Sight glass with calibration scale
• Aeration valve
ØL
H
Ød
G
M
ØD
I
Technical data
45
10 Accessories for dosing pumps
D
calibration of the pump.
ØF
A manual vacuum pump kit includes:
A
• Ball valve, connection G 5/8"
• T-piece, connection G 5/8"
• Hose
E
• Manual vacuum pump
G
C
• Holder for wall mounting
Materials:
• Vacuum pump: PVC
• Ball valve and T-piece: PVC
A B C D E ∅F Gmin Gmax
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
131 34 132.5 50 242 6.2 675 875
Order data
Product
Description
number
Manual vacuum pump kit 99218131
TM06 8426 0516
46
Accessories for dosing pumps
10
Calibration columns
B
• Aeration valve on top
• Shut-off valve on the bottom
ØF
In installations without flooded suction, the optional
E
manual vacuum pump kit simplifies the startup of the
dosing pump. See Manual vacuum pump kit on page
46.
Calibration columns must not be used as pulsation
dampers. ØD
Technical data
47
10 Accessories for dosing pumps
ØC
H
• T-piece, connection G 5/8"
• Hose
ØI
• Manual vacuum pump
• Holder for wall mounting
G
Materials:
E
• Vacuum pump: PVC F
B
• Ball valve and T-piece: PVDF
A max
A min
• Gasket: FKM
ØD
B [mm] 242
∅C [mm] 6.1
∅D [mm] 12
E [inch] G 5/8
F [mm] 206
G [mm] 51
H [mm] 206
∅I [mm] 12
∅J [mm] 12
K [mm] 40
Order data
Product
Description
number
Vacuum pump kit for calibration columns 99226934
48
Accessories for dosing pumps
10
Discharge-side pulsation dampers DB and DBG
B
• PVC versions are prepared for pipe gluing
connection with spigot (D) or socket (d).
• PVDF and PP versions are prepared for pipe
ØF
E
welding connection with spigot (D) or socket (d).
• Pulsation dampers DBG include a pressure gauge.
A1
A2
A3
max. H
min. H
ØD1
TM06 8424 0517
ØF
A1
A2
* SS 1.4404
49
10 Accessories for dosing pumps
Technical data
Accessories for medium-sized dosing pumps up to 460 l/h
* SS 1.4404
** Max. operating pressure of pulsation dampers type DBG are limited by the pressure gauge to 25 bar.
50
Accessories for dosing pumps
10
Filling devices for pulsation dampers DB and DBG
C
136
B
A
51
10 Accessories for dosing pumps
Technical data
52
Accessories for dosing pumps
10
Electric stirrers
A
A
E E
F F
C C
B B
15
L(SS)
16
L(PP)
20
TM04 8638 4112
P
D D
Fig. 59 Electric stirrer, stainless steel version Fig. 60 Electric stirrer, PP version with sealing flange
Technical data
53
10 Accessories for dosing pumps
60 1 220-240 50/60
0.09 IP65
100 3 220-240 / 380-420 (440-480) 50/60 (60)
200 1 220-230 50
300 0.25 F
500 3 220-240 / 380-415 50/60
IP55
1 220-230 50
1000 0.55
3 220-240 / 380-415 50/60
54
Accessories for dosing pumps
10
Withdrawal devices
D
• Hose connection kit up to 60 l/h: 4/6 mm, 6/9 mm, 6/
F
12 mm and 9/12 mm
C
– for hoses with internal diameter 19 or 20 mm
B A
– for pipes with external diameter 25 mm
Fig. 61 Withdrawal device, G 5/4"
Max. flow A B C D E F G
[l/h] [mm] [mm] [inch] [mm] [mm] [mm] [inch]
60 143 27 75 G 5/8
14 G 3/4 41
460 151 30 87 G 5/4
Technical data
Withdrawal device with ball valve with through-bolt for FKM 99226879
60 PVC
connection to the dosing tank EPDM 99226880
Withdrawal device with ball valve with through-bolt for FKM 99226881
460 PVC
connection to the dosing tank EPDM 99226893
55
10 Accessories for dosing pumps
Adapters
Accessories for medium-sized dosing pumps up to 460 l/h
Threaded adapters
PP FKM/EPDM 99227512
FKM/EPDM 99227943
DN 32 → DN 20 G 2" G 5/4" PVC
PTFE 99227960
FKM/EPDM 99227953
PVDF
PTFE 99227948
PP 99228667
PVDF 99228669
Elbow adapter
An elbow adapter can be installed, if the space on the inlet side of the pump is confined.
56
Accessories for dosing pumps
10
Wall or tank mounting assembly for SMART Digital XL DDA/DDE
F
M L
K
C
B
N A
H
I G
Fig. 62 Side view, wall or tank mounting assembly Fig. 63 Back view, wall or tank mounting assembly
Technical data
Materials Product
Variant
Body Gaskets number
FKM 99211372
With pulsation damper PVC
EPDM 99211483
Without pulsation FKM 99211484
PVC
damper EPDM 99211485
57
10 Accessories for dosing pumps
Tank accessories
Accessories for medium-sized dosing pumps up to 460 l/h
Wall brackets
• For assembly of one of the mentioned pump types
• With installation material for wall mounting and
pump mounting
Product
For pump type Material
number
DMX 221, DDI 222 PP 91836471
DMX 226, DMH 251-253,
DME 60-10 / 150-4, PE 99211245
SMART Digital XL DDA/DDE
58
SMART Digital XL
11
Pumped liquids
The resistance table below is intended as a general The data shown are based on information from various
guide for material resistance (at room temperature), sources available, but many factors (purity,
and does not replace testing of the chemicals and temperature etc.) may affect the chemical resistance of
pump materials under specific working conditions. a given material.
Note: Some of the liquids in this table may be toxic,
corrosive or hazardous. Please be careful when
handling these liquids.
Material
Pumped liquid (20 °C)
Dosing head Gasket Ball
(Accessories)
SS 1.4435
Ceramic
Chemical Concentration
Description
EPDM
PVDF
PTFE
formula %
FKM
PVC
PE
25 ● ● ● - ● ● ● ●
Acetic acid CH3COOH 60 ● ● ● - ● ● ● ●
85 - ● ❍ - - ● ● -
Aluminium chloride AlCl3 40 ● ● - ● ● ● ● ●
Aluminium sulphate Al 2(SO4)3 60 ● ● ● ● ● ● ● ●
Ammonia, aqueous NH4OH 28 ● - ● - ● ● ● ●
Calcium hydroxide 1) Ca(OH)2 ● ● ● ● ● ● ● ●
Calcium hypochlorite Ca(OCl)2 20 ● ● - ● ● ● ● ●
10 ● ● ● ● ● ● ● ●
Chromic acid H2CrO4 30 ● ● - ● ❍ ● ● ●
50 ● ● - ● - ● ● ●
Copper sulphate CuSO4 30 ● ● ● ● ● ● ● ●
Ferric chloride 2) FeCl3 60 ● ● - ● ● ● ● ●
Ferric sulphate 2) Fe 2(SO4)3 60 ● ● ❍ ● ● ● ● ●
Ferrous chloride FeCl2 40 ● ● - ● ● ● ● ●
Ferrous sulphate FeSO 4 50 ● ● ● ● ● ● ● ●
Fluosilicic acid H2SiF6 40 ● ● ❍ - ❍ ● ● ●
< 25 ● ● - ● ● ● ● ●
Hydrochloric acid HCl
25-37 ● ● - ● ❍ ● ● ●
Hydrogen peroxide H 2O 2 30 ● ● ● ● ● ● ● ●
30 ● ● ● ● ● ● ● ●
Nitric acid HNO3 40 ● ● ● ● - ● ● ●
70 - ● ● ● - ● ● ❍
Peracetic acid CH3COOOH 5-15 ❍ ● ❍ - - ● ● ❍
Potassium hydroxide KOH 50 ● - ● - ● ● ● ●
Potassium permanganate KMnO 4 10 ● ● ● ❍ ● ● ● ●
Sodium chlorate NaClO3 30 ● ● ● ● ● ● ● ●
Sodium chloride NaCl 30 ● ● - ● ● ● ● ●
Sodium chlorite NaClO2 20 ❍ ● - ● ● ● ● ●
30 ● ● ● ❍ ● ● ● ●
Sodium hydroxide NaOH
50 ● ● ● - ● ● ● ●
Sodium hypochlorite NaClO 12-15 ● ● - ● ● ● ● ●
Sodium sulphide Na 2S 30 ● ● ● ● ● ● ● ●
Sodium sulphite Na2SO3 20 ● ● ● ● ● ● ● ●
Sodium thiosulfate Na2S2O3 10 ● ● ● ● ● ● ● ●
Sulphurous acid H 2SO3 6 ● ● ● ● ● ● ● ●
< 80 ● ● - ● ❍ ● ● ●
Sulphuric acid 3) H2SO4 80-96 ● ● - ● - ● ● -
98 - ● ● ❍ - ● ● -
● Resistant 1)
Once the pump is stopped, calcium hydroxide will sediment rapidly.
❍ Limited resistance 2)
Risk of crystallisation.
- Not resistant 3) Reacts violently with water and generates much heat.
(Pump should be absolutely dry before dosing sulphuric acid.)
Further information:
http://product-selection.grundfos.com/liquids.html
59
12 SMART Digital XL
http://product-selection.grundfos.com
Subject to alterations.