Professional Documents
Culture Documents
This User Manual is about the functions and operation process of the inverter. Please
read this User Manual carefully before operation for correctly using the inverter and
keep this User Manual properly for future reference in case of any problem.
Attentions:
1. This User Manual is subject to change without notice and the latest version
prevails.
3. Any copying or rearranging of any part or whole of this User Manual without
• Overall dimensions
• Installation dimensions
• Optional accessories
• Wiring precautions
• Parameters
02
Chapter I Overview 1.3 Use precautions
Before unpacking, please check whether the packing container is damaged due to the
transportation.
After unpacking, please check whether the inverter and accessories are in normal Dangers:
conditions and whether the rated values on the nameplate are consistent with that in 6 Make sure that the power is shut off before wiring.
your order requirements 7 Have an electrical technician wire the machine up.
In case of any exception, please contact the supplier or 8 Have the grounding terminal reliably grounded.
■ Safety precautions
Attentions:
■ Make sure that the voltage of the AC circuit is as same as the rated
Attentions:
voltage of the inverter.
• Do not install the inverter which is damaged or short of any part.
■ Do not disconnect any terminal while the machine is powered on and
• Hold the bottom of it when carrying the machine for fear that the
running.
main body might drop down to injure anyone.
■ Do not touch the battery switch while the battery is being charged at
• Do not place any liquid on/above the machine for fear that the liquid
a high current.
might spill onto the machine.
■ Do not clog the ventilation hole of the machine.
03
Chapter II Product Specification Rated
50Hz±0.5% (60Hz±0.5%)
Output
Outp
Pure sine wave
ut
2.1 Application range Distort
≤3%
ion
■ Important computer systems in securities exchanges, bank, hospitals, etc.; Inversi
80%~85%
on
■ Fire protection, lighting, monitoring and other systems in buildings; When the load is 120% to 160% of the rated load, the machine maintains output
Overl for 7s to 10s; when the load is 160% to 200%, the machine maintains output for 3s
■ Transportation systems covering lighting systems in expressways, tunnels, oad to 7s; when the load is over 200%, the machine maintains output for 1s, shuts
Capa down and gives out long alarm sounds
metros, airports, etc.; DC Input
Inp
■ Production, experimental and other equipment which must not be ut 12V / 2 / 48V
Batt 4
Batt V
powered off;
ery 10V-16V / 20V-32V / 40V-64V
Volt
■ Household electrical appliances.
AC Input
Inpu
t 160~270VAC (95VAC-140VAC)
• Types Volt
Input
5 Household inverter Freque 45~55Hz (55~65Hz)
ncy
6 Solar inverter Po
0.9
we
7 Pure inverter Outp
ut As same as that of mains supply
Voltag
Output
• Technical specifications Freque Synchronous with the input frequency
ncy
Data 1,00 2,00 3,00 4,00 5,00 6,00 8,00
Mo 500V Cha
del A 0 0 0 0 0 0 0 13.7V / 27.5V / 55V
rge
Rated
350 700 1,400 2,100 2,800 3,500 4,200 5,600 Cha
Outpu 10A / 20A(30A) / 30A(50A)
W W W W W W W W rge
Maxim 1.
3. 6.4 9. 12. 15. 19. 25.
um 6
2A A 5 7A 9A 1A 5A Other Parameters
Outp A
(6. (12. A (25. (31. (38. (50. Convers
Rated ≤4mS
220VAC±1% (110VAC±1%) ion
Output
Protect Over-temperature protection / overload protection / short circuit protection /
ion battery under-voltage protection / battery over-voltage protection
04
Mach
≤40Db(1mter)
ine
Workin
g
-20~50℃
Ambien
t
Work
ing 5%~90% (no droplet condensed)
Ambi
Work
ing ≤1,500M
Ambi
Connecting terminals of inverter
• Description of external structure
• Overall dimensions
• Installation dimensions
Battery terminals of inverter
05
Battery terminals of inverter/ Connecting terminals of inverter
• -1 Installation dimensions
06
LCD control panel of inverter
Model A B
below:
Chapter III Installation and Wiring of Inverter
Configuration Table of AC110V Input/Output Wires
Mo 500VA/ 1,000VA 2,000VA 3,000VA 4,000VA 5,000VA
del 110VA / / / / /
4.2 Environmental conditions for installation
WireL-IN C≥1 ㎟ 110VA
≥2 ㎟ 110VA
≥4 ㎟ 110VA
≥6 ㎟ 110VA
≥8 ㎟ 110VA
≥10 ㎟
4.2.5 The machine must be installed in a well-ventilated place. N-IN ≥1 ㎟ ≥2 ㎟ ≥4 ㎟ ≥6 ㎟ ≥8 ㎟ ≥10 ㎟
G ≥1 ㎟ ≥2 ㎟ ≥4 ㎟ ≥6 ㎟ ≥8 ㎟ ≥10 ㎟
4.2.6 The ambient L-OUT ≥1 ㎟ ≥2 ㎟ ≥4 ㎟ ≥6 ㎟ ≥8 ㎟ ≥10 ㎟
temperature must be within -20 ℃ to 50℃. N-OUT ≥1 ㎟ ≥2 ㎟ ≥4 ㎟ ≥6 ㎟ ≥8 ㎟ ≥10 ㎟
≥1 ㎟ ≥2 ㎟ ≥4 ㎟ ≥6 ㎟ ≥8 ㎟ ≥10 ㎟
4.2.7 The ambient humidity must be lower than 95%RH to ensure there Configuration Table of AC220V Input/Output Wires
is no droplet condensed. 500V 1,000V 2,000V 3,000V 4,000V 5,000V 6,000V 8,000V
Mo A/ A/ A/ A/ A/ A/ A/ A/
del 220VA 220VA 220VA 220V 220VA 220VA 220V 220V
4.2.8 The machine must not be installed in the place where there is C C C A C C AC AC
L- ≥0.5 ≥1 ㎟ ≥2 ㎟ ≥3 ㎟ ≥4 ㎟ ≥4 ㎟ ≥6 ≥6
IN
N- ㎟
≥0.5 ≥1 ㎟ ≥2 ㎟ ≥3 ㎟ ≥4 ㎟ ≥4 ㎟ ㎟
≥6 ㎟
≥6
corrosive or explosive gas.
IN
G ㎟
≥0.5 ≥1 ㎟ ≥2 ㎟ ≥3 ㎟ ≥4 ㎟ ≥4 ㎟ ㎟
≥6 ㎟
≥6
L- ㎟
≥0.5 ≥1 ㎟ ≥2 ㎟ ≥3 ㎟ ≥4 ㎟ ≥4 ㎟ ㎟
≥6 ㎟
≥6
4.3 Wiring precautions
OUT
N- ㎟
≥0.5 ≥1 ㎟ ≥2 ㎟ ≥3 ㎟ ≥4 ㎟ ≥4 ㎟ ㎟
≥6 ㎟
≥6
OUT ㎟ ㎟ ㎟
Configuration Table of Input Wires to Battery
500V 1,000V 2,000V 3,000V 4,000V 5,000V 6,000 8,000
Mo A A A A A A VA VA
del
12V 8㎟ 16 ㎟ 25 ㎟
Attentions: 24V 4㎟ 8㎟ 16 ㎟ 16 ㎟ 25 ㎟ 35 ㎟
48V 2㎟ 4㎟ 8㎟ 10 ㎟ 16 ㎟ 16 ㎟ 16 25
㎟ ㎟
4.3.5 Make sure that the power is shut off before wiring.
08
■ UNDER-VOITAGE Battery Under-voltage/Over-voltage Indicator Light
Chapter IV Operation Guide of Inverter
■ CHARGING Battery Charging Indicator Light
Shutdown: Press “Off” for 5 seconds, and then the machine shuts down.
4.2.2 Parameter setting on LED control panel
09
Note: 25%, 50%, 75% and 100% are invalid when the machine is powered by mains (6)、REIT High Points:
supply and they respectively indicate the battery level when the machine is powered Traditional power inverters used in solar, wind and mains hybrid could always be
by battery supply. utilizing mains to charge and supply to loads while the solar and wind are generating
4.2.3REIT Series at the same time. For REIT power inverter, the processor monitors the battery level
(1) 、 REIT series hybrid power inverters are the latest in the alternative power with the power inflow to the battery from the wind and solar generators. Once the
product systems aimed at providing constant power from all sources of power battery goes down or the rate of charge drops from the wind or solar generators, the
available in any environment, we aimed at maximizing the provision and usage of REIT inverter will switch over to the mains for charging and supply to the loads and
power, making it available and affordable with high energy conversion efficiency. (2) thereby saving the battery from over discharge without keeping the user in darkness.
、The REIT series inverter popularly known as inverter with ATS function utilizes (7)、The special bypass function:
the function of a CPU to manage the sourcing of power either from the wind/solar The bypass function of REIT hybrid power inverter is the height of power
operation or from the mains when available for supply to the user with the aim of technology in the design of REIT inverter. The CPU programs the power source
energy save. from the solar and wind as the primary power of source of power, bypassing the
(3)、With the inbuilt 3-stage high capacity charger, the inverter is able to charge the available mains. As the input from the wind and solar reduces, consequent to the
battery bank fast and maintain it over a long period without damage when the source lower level of the batteries, the system is automatically programmed to divert to
is from the mains. mains for the battery replenishment and hence the load support at a transfer speed of
(4)、With bypass function, the inverter can depend on the battery charging from the about 4ms. REIT SERIES
solar or wind generators. At idle mode, the inverter has the capacity to save self (8)Operation of REIT series
battery discharge by going to sleep now referred to as energy saving mode, saving
(5)、The REIT inverter is rugged and proper to be used in remote areas and cities
with little or no professional care. The information displays by LEDs are self explicit
and informative.
10
⑴⑵ Pressing ON or OFF 3 seconds is effective, ⑽Under-voltage or over-voltage protection light. When the battery in under-voltage
⑶ Saving mode button. When you press the this button ,the machine would start mode ,the light would blink and when the machine in under-voltage or over-voltage
saving mode way automatically and corresponding to the saving lamp 9 protection mode, the light would bright on.
bright .Again ,press this button the machine would turn to normal operation mode and ⑾Charging light&Battery capacity light&delay mode light. When the machine is
the saving lamp9 off. Pressing this button 3seconds is effective .Under the utility working under the mains mode,the charging light would bright .Moreover ,for
mode is invalid. charging is blink and for charging finish is bright on . When the machine is working
⑷REIT Delay button ,When in the mains power mode ,press the delay mode button under the battery mode ,the battery capacity light would bright. Moreover ,for battery
after 3seconds the buzzer would sound one time and the machine would adjust the voltage above 25% is blink and for below 25% is bright off.
delay time automatically .The delay mode button would bright following as the delay ⑿Charging current light& Battery capacity light . When the machine is working
time .The user could choose freely depending on their own situations . For under the mains mode, the charging current light is for 10A. When the machine is
example ,when press the delay mode button 3seconds , corresponding to 2 hours on working under the battery mode, the battery capacity light is for 50% light .Moreover,
the indicator means the battery voltage charged to the desired value ,the inverter when the battery voltage is above 50% ,the light is bright on and when the battery
should transfer to solar or wind power supply mode after 2 hours.(Default :1hours) voltage is below 50%, the light is bright off.
⑸Mains light. When the machine is working under the mains mode ,this light would ⒀Charging current light& battery capacity light . When the machine is working
bright. under the mains mode ,the charging current light is for 20A(30A) .When the machine
⑹Battery mode light. When the machine is working under the battery mode ,this is working under the battery mode, the battery capacity light is for 75%
light would bright . light .Moreover, when the battery voltage is above75% ,the light is bright on and
⑺Output light . When the machine has output voltage ,this light would bright . when the battery voltage is below75%,the light is bright off.
⑻Fault light. When the machine has fault and could not work normally ,this light ⒁Charging current light& battery capacity light . When the machine is working
would bright. under the mains mode ,the charging current light is for 30A(50A) .When the machine
⑼ Energy saving light. When the machine is working under the energy saving
is working under the battery mode, the battery capacity light is for 100%
mode ,this light would bright.
light .Moreover, when the battery voltage is above100% ,the light is bright on and
11
when the battery voltage is below100%,the light is bright off.
Press and to select the desired language; press again to save the
selection.
■ Page Down
■ Function Selection
■ Back
• Language setting
Press for language setting; Press and to select the battery model consistent with the real one; press
12
Press for output mode setting;
Press and to select the desired charge current; press again to save
the selection.
Press and to select the output mode; press again to save the
Attentions:
Press again for frequency selection;
■ Normal mode: Normal output.
■ Eco mode: The output voltage is reduced by 20V to save energy under the
precondition that the final output voltage of the machine is normal. This
Press and to select the desired frequency; press again to save the mode is mainly applicable to road lighting and indoor/outdoor lighting.
selection.
■ Power-saving mode: When the load is above 200W, the machine remains
normal output. When the load is below 150W, the machine stops the output
3.10 Output mode setting
13
and, after 1 minute, starts the output; when the machine again detects that
the load is below 150W, it stops the output (i.e., cyclic output). This mode
Attentions:
Press and to select the power supply priority mode; press again to 12V battery under-voltage protection point: 11V, 10.5V, 10V, 9.5 V
save the selection.
24V battery under-voltage protection point: 22V, 21V, 20V, 19 V
14
Press for battery capacity setting;
Chapter V Performance and Parameters of Inverter
■ Capacity calculation
An electrical appliance, which is a load in a circuit, is usually marked with the values
of rated power, rated current, power factor, and other parameters. However, there is
much difference among different types of loads, but there must not be much
Press again for battery capacity selection;
difference between the actual total power of the loads and the rated power of the
machine, so the total actual power should be the sum of active power of all the loads
but not the simple sum of the rated power of all the loads. Because mostly the loads
are household electrical appliances and their power factor values are between 0.65 to
0.7, the total actual power can be the sum of the rated power of all the loads; as for
the loads of other types such as printer, etc., the active power must be the rated power
Press and to select the battery capacity consistent with the real one; press
again to save the selection. multiplied by a certain factor according to the starting power and then is added to the
sum. On the basis of the total capacity of all the loads, the inverter capacity can be
determined according to the formula: inverter capacity >= total capacity of loads ÷
0.8, that is to say, the total capacity of all the loads must be less than 80% of the rated
capacity of the inverter because the impulse current of load startup and the future
Not all electrical equipment needs an inverter; vice verse, an inverter is not applicable
to all electrical equipment. A user to choose a load of an inverter must take into
15
consideration the sizes, features and importance of the load as well as the influence
12V 10V 10.5V 16V
by harmful power on the load.
24V 20V 21V 32V
capacitive loads, and non-liner loads containing rectifier circuits (such loads are also
■ Over-temperature protection
called rectifier loads), including computers and the peripheral equipment. An inverter
When the internal temperature of the inverter reaches 35 , the fan begins working to
is applicable to resistive loads and capacitive rectifier loads.
dissipate heat; when the internal temperature reaches 100
normal running of a computer or any other rectifier load leads to the current peak
■ Overload protection
factor being 2 to 3, that is to say, the current peak value is 2 to 3 times of the effective
When the actual load is 50% over the rated load, the machine enables 10s overload
current value. Therefore, a user to choose an inverter must take account of such
protection; when the actual load is 100% over the rated load, the machine enable 1s
feature and leave a margin to the inverter. As for the inductive loads with small power
overload protection.
factors, such as air conditioner, etc., the starting current is very high, which may be 5
to 7 times of the rated current, and the startup is very frequent, so the ordinary small
■ Output short circuit protection
or medium inverter is not applicable unless enough margin has been left.
When the output short circuit occurs, the machine enables short circuit occurs within
0.1s.
■ Performance and parameters
■ Self-check and report
2 Battery under-voltage/Over-voltage protection
In case of any exception in running, the machine automatically analyzes the reason
Battery Battery Battery
and gives out audible-visual alarm.
Under- Under- Over-voltage
16
The cycle-by-cycle current limiting prevents the damage caused by high current Charging:
switching, loading, unloading, short circuit or impulse. Three-step charging (respectively constant current charging, constant voltage
the battery.
• Battery model selection
The battery supply duration mainly depends on the factors such as load capacity,
Generally, to calculate the battery supply duration, it is a way to calculate the battery
Caution!
discharge current and then look up the discharge time in the battery discharge curve.
The battery discharge current can be calculated according to the empirical formula: 1 When inserting & connecting the battery, if the battery acid comes into contact
with skin or clothing, please instantly wash the skin or clothing by clean water
discharge current = Inverter capacity (VA) × power factor / average battery discharge and soap; if it comes into contact with eyes, please instantly flush the eyes by
voltage × efficiency cold water for at least 20 minutes and instantly send the injured one to hospital
for treatment. To prevent danger, the operator must wear safety goggles and
When to calculate the actual load discharge time, it only needs to replace the above safety clothing when operating on battery; in particular, the operator must keep
inverter capacity with the actual load capacity. the tools and jewelry away from the batter when operating for fear that any
The user can determine the proper battery model on the basis of the calculated battery 2 When connecting the inverter with the battery, please make sure that the battery
supply duration according to the above formula. polarity is correct for fear that the inverter might be damaged or accident might
17
be incurred. Frequency Capacity Temperature Load
8 Please do not replace the battery connecting wire without permission because Normal
Equipm Normal Battery Non-
nonconforming wire or nonstandard wire may cause damage to the inverter. ent Mains Voltage Normal UPS Non-test bypass
Wiring Supply Status Status
2.2 Please shut the power off and then connect the power grid for fear that one might
Time Event
get an electrical shock. Informat
ion
Manufactu UPS 5K- Version 1.0
Chapter VII Monitoring rer: 11A
Richcomm
Introduction
monitoring and network agent monitoring via COM port and USB port. It clearly
displays figures and graphs of the real-time input/output voltage, frequency, load,
temperature, battery capacity and other data to help the user monitor the power
supply quality. It also sends control instructions to the inverter to control the latter to
help the user manage the power more efficiently. Moreover, by preset control
instructions, it controls the inverter at a fixed time; in case of mains supply failure or
low battery potential, it gives full play to the unmanned monitoring function by
automatically saving information safely and accurately, shutting down system safely,
alarm, autodialing to send mobile-phone message alarm and sending E-mail alarm,
系统 查看 控制 帮助
System View Control Help etc., so the user need not worry about that the mains supply failure may cause any
输入电压 电池容量 机内温度 输出电压
Input Voltage Battery Internal Output Voltage loss to any system or archive. The system is capable of necessary emergency
18
handling instantly and also capable to record the information of the recent days. Chapter VIII Maintenance
input/output terminal of the inverter and whether the fan of the inverter is in
19
good condition.
2 Have an electrical technician replace the battery and deliver the replaced battery
4 To periodically conduct battery charging/discharging test to activate the
to recycler for treatment.
performance of the battery and prolong the service life of the battery. The
battery life depends on the ambient temperature and the discharge cycle times.
Inverter Maintenance Record Table
When the ambient temperature is about 20℃, the average battery life is about 3 Maintena Maintenance Content Maintainer
nce Signature
to 5 years; when the ambient temperature is over 30℃, the battery life is
shortened accordingly. For a new battery, the capacity usually increases after
few charging-discharging cycles, then remains stable, and finally decreases after
for 2 to 3 times within the first two months and to charge and discharge it every
1 or 2 months later.
20
After the user presses “On’, the buzzer The battery over-voltage/ • Inverter damage caused by running the inverter in adverse working conditions
sounds all the time and the battery under
under-voltage indicator light is on all -voltage protection is enabled. stated in the User Manual;
the time.
Machine is The inverter only runs with light load. The power line is loose. • Inverter damage caused by the installation or application range nonconforming
protected
w to the related international standards;
Battery All the battery capacity indicator lights The battery voltage is low.
capacity are on when the machine is at empty • Inverter damage due to unusual natural environment.
indicator lights load and none is on when the machine is
Battery None of the battery capacity indicator The battery voltage is low.
under-voltage lights is on when the machine is at
indicator light empty load and any of them blinks
is exceptional. when the machine is at any load.
8.4 Warranty
provides after-sales service of the inverter under the precondition of the following:
■ If any fault or damage occurs to the inverter in normal use, Beijing Remote
Power Renewable Energy Technology Company is responsible for repair for free
within 15 months after the selling and responsible for paid repair after the 15
months;
■ The paid repair also covers any of the following situations within 15 months after
the selling:
• Inverter damage caused by not following the operation steps stated in the
User Manual;