You are on page 1of 1

Supreme ABF Construction

& Construction Supply Company Inc.


Napoleon R. Gonzaga St., Brgy. 31 Bacolod City 6100
Telefax No.(034) 433-6192
Supreme ABF Const & Const Supply Co., Inc. is ISO 9001-2008 Certified

(JOINT VENTURE)

Project : Construction/Concreting of Silay - Patag Access Road Leading to Patag Valley (Patag Valley Trekking), Silay City, Negros Occidental (16RO0007)
Kind of Materials : Embankment (From Roadway Excavation) Spec's Item No. : 104a
Sampled at : Jobsite
Original Source : Jobsite
Sampled by : R. Antolin-Redson & Supreme ABF (JV) / M. Pacete, Jr. Date : 8/11/2016
Tested by: : R. Antolin-Redson & Supreme ABF (JV) / M. Pacete, Jr. Date : 8/12/2016
Computed by : R. Antolin-Redson & Supreme ABF (JV) / M. Pacete, Jr. Date : 8/12/2016

Lab. No. : 16RO0007-213

MOISTURE & DENSITY RELATION OF SOIL

Sample Identification Laboratory Number: 2010


TRIAL NUMBER 1 2 3 4 5 2000
Water Added 100 100 100 100 100 1990
Mass Mold + Wet Soil 9733 9920 10095 10235 10250
1980
in Mold 5400 5400 5400 5400 5400

Dry Density, kg/cu.m


Grams Wet Soil 4333 4520 4695 4835 4850 1970

Wet density Kg/m3 2039 2127 2209 2275 2282 1960


Can Number CT-2 CT-28 AC-23 C-1 MC-31 1950
Can + Wet soil 53.97 52.71 56.36 62.84 56.92 1940
Mass Can + Dry soil 51.83 49.7 52.37 57.34 50.58
1930
in Water. 2.14 3.01 3.99 5.5 6.34
Grams 1920
Can 16.23 14.32 16.07 20.70 15.35
Dry Soil 35.6 35.4 36.3 36.6 35.2 1910
Moisture Content, % 6.00 8.50 11.00 15.00 18.00 1900
Dry Density Kg/m3 1924 1960 1990 1979 1934 4.00 8.00 12.00 16.00 20.00
Moisture Content %
Method used T-180
Weight of rammer.kg 4.5
Voume of mold, cu.m 0.002125
No. of Layer 5 PREPARED BY: WITNESSED BY:
No. of blows per layer 56
Maximum dry Density Kg/cu.m. 1990 RAMON S. ANTOLIN MELECIO B. PACETE, JR.
Optimum moisture content, % 12.0 Materials Engineer-Contractor Materials Engineer-DPWH