Year 5
Power stream
Section 1 and 2
Course Contents
SCADA Systems
Electronic Devices.
PROCESS
PLANT
July 23, 2021 5
TRANSPORT SYSTEM PETROCHEMICAL PLANT
16 Digital i/o SITE monitoring Pager
Time Sync Notification
2 Analogue inputs
2 control outputs
1 RS232 port 10 RouteT LAN
Remote
Telemetry Sites
Units 1-8
(RTU)
Rs232
SNMP
monitoring
Dial-up remote
Access
Alarms from remote DPS TELECOM SCADA
July 23, 2021 equipment SYSTEMS 6
A SCADA system performs four functions:
1. Data acquisition
2. Networked data communication
3. Data presentation
4. Control
channels.
3. System frequency.
Rate limiting: All AGC designs must account for the fact that
units cannot change their output too rapidly.
This is especially true of thermal units where mechanical and
thermal stresses are limiting. The AGC must limit the rate of
change such units will be called on to undergo during fast load
changes.
Unit control modes: Many units in power systems are not
under full AGC control. Various special control modes must be
provided such as manual. base load, and base load and regulating.
For example. base load and regulating units are held at their base
load value but are allowed to move as assist action dictates, and
are then restored to base-load value
Relay is a device that detects the fault and initiates the operation of
the CB to isolate the defective element from the rest of the system.
7/23/2021 51
Purpose of System Protection
Generators
Transformers
Reactors(components of electric ckt used to create
reactance)
Lines
Buses
Capacitors
7/23/2021 70
Continued…
% of winding unprotected = (R x Io / V) x 100
20 = (R x 65.5 / 6340) x 100
Therefore,
R = 1.94 ohm
7/23/2021 71
Transformer Protection
Why transformer protection ???
To Protect the Transformer from severe damages.
Time required to rectify the Transformer in case of damages is
more and it is very difficult.
7/23/2021 72
What cause transformer failure?
Winding Bushing
Insulation deterioration come Bushings deterioration come
from: from:
Moisture General aging
Contamination
Vibration
Cracking
Overheating Internal moisture
Voltage surge
7/23/2021 73
Transformer Protection Scheme
Mechanical Electrical
1. Bias Differential Protection
1. Buchholz relay 2. Over Fluxing
2. Sudden pressure 3. Over Voltage
4. Under Voltage
3. Pressure relief 5. Neutral Unbalance
4. Temperature 6. Restricted Earth Fault
protection 7. Back up O/C & E/F
7/23/2021 74
Comparison of Electro-Mechanical to Microprocessor-Based
Protective Relays
Advantages of Electromechanical
Lower Cost
Easier to Test
Disadvantages of Electromechanical
Need three individual relays
Maintain more often
Moving Parts
Usually performs only one protective function
Slower operating than Micro-Processor Based
FACTS devices
Power Flow Control on AC Systems
2
Radial
Parallel
Meshed
Line Enhanced
Transmission Power Transfer
Reconfiguration
Link and Stability
Better
Protection SVC
FACTS STATCOM
Increased TCSC, SSSC
Devices UPFC
Inertia
Shunt Connected
Static VAR Compensator (SVC)
Static Synchronous Compensator (STATCOM)
Static Synchronous Generator - SSG
Battery Energy Storage System (BESS)
Superconducting Magnetic Energy Storage (SMES)
Fast
SMES Real Power Injection
and Absorption
P
TSSC
P TSSC
P
SSSC Additional
UPFC SSSC
UPFC
Stability
Margin
Electric Grid Electric Grid
2
Q STATCOM Q STATCOM
1.5
Acceleration
Area
Deceleration
Area
Power Transfer
1 Stability
Margin
Fast Fast 0.5
No Compensation
60
.8
59
.2
time (sec)
59 59
.2 .2
time (sec)
time (sec)
Voltage and Stability Control Enhanced Voltage and Stability Control
(2 x 80 MVA Inverters) ( 80 MVA Inverter + 100Mjs SMES)