Where a project team is considering using a LCA tool which has not been previously evaluated by BRE Global (BREG), the
template and Mat 01 Calculator to BREG. The evaluation process of LCA tools often requires the involvement and issue o
Knowledge Base Compliance Note KBCN01118 confirms all verified LCA tools, and the BREEAM schemes they are recogn
Further guidance on Mat 01 Calculator terms (when undertaking the evaluation of a tool)
Elemental level
To award this point, the tools must have the ability to analyse different building element systems, such as comparing on
Element level comparison does not refer to, for example, the ability to compare the all external wall impacts with all roo
Geographic applicability
To award this point, the tool must use LCA data that is based on background data (such as primary manufacturing data)
LCA data is from another region, it must be compensated (adjusted) to allow for a comprehensive range of regional diffe
resource availability, transport and waste disposal routes. The compensation should be at the product level, not a globa
publically available and peer reviewed.
Methodologies/PCRs
This refers to the methodology(ies)/PCR(s) used to create the LCA data available in the tool.
Verification
This section relates to the independent verification of the LCA data to the respective methodology(ies)/PCR(s) identified
Note: Although methodologies/PCRs may set requirements for independent verification, it may not have been carried ou
Where the calculator confirms that the mandatory credits have been met and credits are awarded, enter the
to confirm the number of credits to award against the BREEAM-NOR scheme:
Credits achieved:
ulator
aluated by BRE Global (BREG), the assessor should send the completed evidence
uires the involvement and issue of evidence by the tool producer or developer.
REEAM schemes they are recognised against. This calculator should be read in conjunction with the KBCN.Each verified LCA tool has it
ool)
und LCA data for life stages A, B and C (as defined by EN15978) must be specific to the
age B, replacement quantities should be based on robust service life information and
ign. Stage C should be based on current product specific waste processing (i.e.
nt systems, such as comparing one complete external wall construction with another.
external wall impacts with all roof impacts.
as primary manufacturing data) from the same region as the building. Or, where the
prehensive range of regional differences e.g. grid-mix, production, technological,
at the product level, not a global adjustment. The compensation methodology must be
tool.
d credits are awarded, enter the percentage Mat 01 calculator points below
e:
oints achieved:
edits achieved: 0
BREEAM International New Construction 2016 Mat 01 Calculator
Cells that
Cells thatare
arewhite
whitewith
withaa black
black border
border require
requirethe
theuser
user to
toinput
input information,
information,either
eitherby
by selecting
selectingfrom
from
theavailable
the available options
optionsor
or entering
entering the
the required
required data.
data.
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
Included in
(if present)
Present in
Maximum
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 N 0 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 N External walls (envelope, structure and finishes) M Y 2.00 N
AND any two additional indicators 4 N External windows and rooflights M Y 2.00 N NOTE: Other sections are usually completed once by the tool developer
Points 8 0 Foundations (including excavation) Y 2.00 N as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 N
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 N
Cradle to Gate total 2 N 0 Upper floors (including horizontal structure) M Y 2.00 N
Cradle to Gate total AND End of Life 4 N Basements/retaining walls (including excavation) Y 1.00 N
Cradle to Grave total 6 N External solar shading devices, access structures etc. Y 1.00 N
Cradle to Grave total WITH operational energy (reported separately) 8 N Ground/lowest floor Y 1.00 N
Cradle to grave with separate life stage reporting* to:- 12 N Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 N
a. Product stage Internal walls and partitions M Y 1.00 N
b. Construction process stage Roof (including coverings) M Y 1.00 N
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 N
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 0 Internal doors Y 0.50 N
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 N
made) at the: Sum:-
Elemental level* 4 N 0 Internal windows Y 0.50 N
Whole Building Level 4 N Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 N
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 0 Electrical Installations Y 1.00 N
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local
conditions
0 N Lift and Conveyor Installations / Systems Y 1.00 N
0
Using local LCA data or LCA data that has been compensated to a comprehensive
range of regional differences*
5 N Water and waste installations Y 1.00 N
0
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 N Sanitary Installations Y 0.50 N
0
*see guidance tab Points 10 0 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 N
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 N
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the
current version of) ISO 14040 & ISO 14044
4 N Total Points 30.0 0.0
0
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 N
compliant with (the current version of) ISO 14040 & ISO 14044
0
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 0.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 N 0
EN 15804 4 N 0
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 N
0
Select building type: All others
*see guidance tab Points 20 0
Credits achieved 0
(M) Source LCA data quality - Verification* Note: Not all mandatory issues
Majority of individual materials/products in the tool are have been met
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 N 0 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 N
association) are verified to ISO 14025, ISO 21930 or EN 15804 0
*see guidance tab Points 10 0
Total points 70 0
Discounting for future emissions (e.g. to adjust for future changes to energy N
supply (fuel mix, technology etc.))
Where indicated above as including operational energy (heating, cooling, power etc)
the following quantities have been used (direct, kWh/year) :
grid electricity enter quantity
natural gas enter quantity
coal enter quantity
oil enter quantity
other, please specify fuel type enter quantity
BREEAM International New Construction 2016 Mat 01 Calculator
Cells that
Cells thatare
are white
whitewith
with aablack
black border
borderrequire
requirethe
theuser
user to
toinput
inputinformation,
information,either
eitherby
by selecting
selecting from
from
theavailable
the available options
options or
or entering
entering the
therequired
requireddata.
data.
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 Y
*see guidance tab Points 10 10 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 Y
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 N Lift and Conveyor Installations / Systems Y 1.00 Y
conditions 0
Using local LCA data or LCA data that has been compensated to a comprehensive 5 Y Water and waste installations Y 1.00 Y
range of regional differences* NORWAY ONLY 1
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 30.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 100.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 70
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 Y
*see guidance tab Points 10 10 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 Y
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 N Lift and Conveyor Installations / Systems Y 1.00 Y
conditions 0
Using local LCA data or LCA data that has been compensated to a comprehensive 5 Y Water and waste installations Y 1.00 Y
range of regional differences* GERMANY ONLY 1
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 N
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 N
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 28.5
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 98.5%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 70
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 N
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 Y Lift and Conveyor Installations / Systems Y 1.00 N
conditions 1
Using local LCA data or LCA data that has been compensated to a comprehensive 5 N Water and waste installations Y 1.00 N
range of regional differences* 0
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 5 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 22.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 87.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 65
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 N
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 Y Lift and Conveyor Installations / Systems Y 1.00 N
conditions 1
Using local LCA data or LCA data that has been compensated to a comprehensive 5 N Water and waste installations Y 1.00 N
range of regional differences* 0
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 5 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 22.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 87.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 65
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 Y
*see guidance tab Points 10 10 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 Y
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 N Lift and Conveyor Installations / Systems Y 1.00 Y
conditions 0
Using local LCA data or LCA data that has been compensated to a comprehensive 5 Y Water and waste installations Y 1.00 Y
range of regional differences* 1
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 30.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 100.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 70
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 Y
*see guidance tab Points 10 10 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 Y
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 N Lift and Conveyor Installations / Systems Y 1.00 Y
conditions 0
Using local LCA data or LCA data that has been compensated to a comprehensive 5 Y Water and waste installations Y 1.00 Y
range of regional differences* 1
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 30.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 100.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 70
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 N
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 5 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the
current version of) ISO 14040 & ISO 14044
4 Y Total Points 30.0 22.0
1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 83.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 N 0
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 16
Credits achieved 5
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 61
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 N
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 5 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the
current version of) ISO 14040 & ISO 14044
4 Y Total Points 30.0 22.0
1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 87.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 65
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 N as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 N
Cradle to Gate total 2 N 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 N Basements/retaining walls (including excavation) Y 1.00 N
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 N
Cradle to Grave total WITH operational energy (reported separately) 8 N Ground/lowest floor Y 1.00 N
Cradle to grave with separate life stage reporting* to:- 12 N Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 N
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 N
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 6 Internal doors Y 0.50 N
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 N
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 N
Whole Building Level 4 N Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 N
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 4 Electrical Installations Y 1.00 N
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 Y Lift and Conveyor Installations / Systems Y 1.00 N
conditions 1
Using local LCA data or LCA data that has been compensated to a comprehensive 5 N Water and waste installations Y 1.00 N
range of regional differences* 0
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 5 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 11.5
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 60.5%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 N 0
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 16
Credits achieved 1
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 49
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Present in
Maximum
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 N
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 N
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 N
d. End of life Balustrades and handrails Y 0.50 N
*see guidance tab Points 12 12 Internal doors Y 0.50 N
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 N
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 N
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 N
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 N
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 N
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 16.5
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR
4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 78.5%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 N
0
Select building type: All others
*see guidance tab Points 20 16
Credits achieved 3
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade
10 N
association) are verified to ISO 14025, ISO 21930 or EN 15804 0
*see guidance tab Points 10 6
Total points 70 62
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Where indicated above as including operational energy (heating, cooling, power etc)
the following quantities have been used (direct, kWh/year) :
grid electricity See note 2 below
1. Dependant on the product categories and defined case-by-case in respect of the EPD normalization
2. Can be adapted in the software case-by-case regarding the building project specifications. Several
assumptions can be compared
BREEAM International New Construction 2016 Mat 01 Calculator
Cells that
Cells thatare
are white
whitewith
with aablack
black border
borderrequire
requirethe
theuser
user to
toinput
inputinformation,
information,either
eitherby
by selecting
selecting from
from
theavailable
the available options
options or
or entering
entering the
therequired
requireddata.
data.
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Present in
Maximum
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 Y Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 12 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local
conditions 0 N Lift and Conveyor Installations / Systems Y 1.00 Y
0
Using local LCA data or LCA data that has been compensated to a comprehensive
range of regional differences* IN FRANCE ONLY
5 Y Water and waste installations Y 1.00 Y
1
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 N
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 N
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the
current version of) ISO 14040 & ISO 14044
4 Y Total Points 30.0 26.5
1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 N
compliant with (the current version of) ISO 14040 & ISO 14044
0
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 76.5%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 N 0
EN 15804 4 N 0
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804. 4 N
0
Select building type: All others
*see guidance tab Points 20 4
Credits achieved 3
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 N
association) are verified to ISO 14025, ISO 21930 or EN 15804 0
*see guidance tab Points 10 6
Total points 70 50
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Where indicated above as including operational energy (heating, cooling, power etc)
the following quantities have been used (direct, kWh/year) :
grid electricity To be defined by the user
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Maximum
Present in
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 N Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 8 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 N
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 8 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local 0 N Lift and Conveyor Installations / Systems Y 1.00 N
conditions 0
Using local LCA data or LCA data that has been compensated to a comprehensive 5 Y Water and waste installations Y 1.00 N
range of regional differences* IN FRANCE ONLY 1
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 Y
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the 4 Y Total Points 30.0 26.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 86.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 Y
1
Select building type: All others
*see guidance tab Points 20 20
Credits achieved 5 + Exemplary
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 N
association) are verified to ISO 14025, ISO 21930 or EN 15804 0
*see guidance tab Points 10 6
Total points 70 60
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
This template confirms the maximum potential score the LCA tool can achieve, for the rigour of the assessment (left hand side) and assessment scope (right hand side). The
design team should confirm with evidence submitted with the report (as detailed in the technical guide) that, for the geographic applicability and the assessment scope aspects,
the tool has been used to the extent listed below. If the tool has not been used to this extent, the template should be amended, to confirm the extent that the tool has been
used. Please also see CN1 as the score will change depending on the number of applicable elements present in the building/assessment.
This score has been approved for MRPI Freetool MPG v1.1
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Present in
Maximum
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 N 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 N Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 N
Cradle to Grave total WITH operational energy (reported separately) 8 N Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 N Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 6 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 N 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 N
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 4 Electrical Installations Y 1.00 Y
(M) Source LCA data quality - Geographic applicability and age Fire and Lightning Protection Y 1.00 N
Majority of individual materials/products in the tool are assessed: Sum:-
Using LCA data of unknown geographic applicability OR not compensated to local
0 Y Lift and Conveyor Installations / Systems Y 1.00 Y
conditions 1
Using local LCA data or LCA data that has been compensated to a comprehensive
range of regional differences*
5 N Water and waste installations Y 1.00 Y
0
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 Y
1
*see guidance tab Points 10 5 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 N
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 N
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the
current version of) ISO 14040 & ISO 14044
4 Y Total Points 30.0 25.5
1
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 74.5%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 Y 1
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 N
0
Select building type: All others
*see guidance tab Points 20 16
Credits achieved 2
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade
10 Y
association) are verified to ISO 14025, ISO 21930 or EN 15804 1
*see guidance tab Points 10 10
Total points 70 49
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Where indicated above as including operational energy (heating, cooling, power etc)
the following quantities have been used (direct, kWh/year) :
grid electricity Not calculated
solar
BREEAM International New Construction 2016 Mat 01 Calculator
Cells that
Cells thatare
are white
whitewith
with aa black
black border
border require
require the
the user
userto
to input
inputinformation,
information, either
either by
byselecting
selectingfrom
from
the available
the available options
options or
or entering
enteringthe
the required
required data.
data.
This template confirms the maximum potential score the LCA tool can achieve, for the rigour of the assessment (left hand side) and assessment scope (right hand side). The
design team should confirm with evidence submitted with the report (as detailed in the technical guide) that the tool has been used to the extent listed below.
If the tool has not been used to this extent, the 'Included in assessment' cells can be changed, or the blank Mat01 Calculator should be filled in to the extent that the tool has
been used. Please also see CN1 as the score will change depending on the number of applicable elements present in the building/assessment.
This score has been approved for novaEQUER v3.1 (2014) and v2.2 (2010) versions.
Please note that for the 1996 version, the 5 points for age of data should be removed.
Please also note that when used for projects outside of France, the 5 points for LCA data geographic applicability should be removed.
Included in LCA
Mandatory Met
assessment?
Mandatory
Mandatory
(if present)
Included in
Present in
Maximum
Maximum
building?
tool?
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:- Building elements included
Embodied carbon (CO2e) M 2 Y 1 Fabric:- Sum:- NOTE: Blue sections are to be checked/completed by the design team
for each BREEAM submission.
Embodied water OR waste processing 2 Y External walls (envelope, structure and finishes) M Y 2.00 Y
AND any two additional indicators 4 Y External windows and rooflights M Y 2.00 Y NOTE: Other sections are usually completed once by the tool developer
Points 8 8 Foundations (including excavation) Y 2.00 Y as part of an evaluation process with BRE Global.
Internal floor finishes (incl. access floors) M Y 2.00 Y
(M) Output Life stage(s) available (for all indicators selected) Score:- Structural frame (vertical) Y 2.00 Y
Cradle to Gate total 2 Y 1 Upper floors (including horizontal structure) M Y 2.00 Y
Cradle to Gate total AND End of Life 4 Y Basements/retaining walls (including excavation) Y 1.00 Y
Cradle to Grave total 6 Y External solar shading devices, access structures etc. Y 1.00 Y
Cradle to Grave total WITH operational energy (reported separately) 8 Y Ground/lowest floor Y 1.00 Y
Cradle to grave with separate life stage reporting* to:- 12 N Internal ceiling finishes (incl. suspended/access ceilings) Y 1.00 Y
a. Product stage Internal walls and partitions M Y 1.00 Y
b. Construction process stage Roof (including coverings) M Y 1.00 Y
c. Use stage (with operational energy reported separately) Stairs and ramps Y 1.00 Y
d. End of life Balustrades and handrails Y 0.50 Y
*see guidance tab Points 12 8 Internal doors Y 0.50 Y
(M) Assessment level(s). Life cycle impact comparisons possible (and Internal wall finishes Y 0.50 Y
made) at the: Sum:-
Elemental level* 4 Y 1 Internal windows Y 0.50 Y
Whole Building Level 4 Y Building Services:-
Whole building level; with user product-level specification (e.g. thickness, service life) Heat Source, Space Heating, Air Conditioning, Ventilation Y 2.00 Y
2 Y
and reporting aligned to (the current version of) EN 15978. Communication, Security and Control Systems Y 1.00 N
*see guidance tab Points 10 10 Electrical Installations Y 1.00 N
Using data no older than 10 years (generic) or 5 years (manufacturer specific) 5 Y Sanitary Installations Y 0.50 N
1
*see guidance tab Points 10 10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y 1.00 Y
(M) Source LCA data quality - Methodologies/PCRs*
Majority of individual materials/products in the tool: Hard Landscaping, Fencing, Railings and Walls Y 0.50 N
Sum:-
Are assessed using data of unknown methodology/PCR 0 N 0 Note: As building-level data is gathered, element weightings will be refined.
Are each assessed to any publicly available methodology/PCR compliant with (the
4 Y Total Points 30.0 24.0
current version of) ISO 14040 & ISO 14044 1
Are each assessed to any publicly available AND peer reviewed methodology/PCR
4 Y
compliant with (the current version of) ISO 14040 & ISO 14044
1
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of): 0 Percentage of Mat01 points achieved: 78.0%
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4 Y 1
EN 15804 4 N 0
Are all assessed to the same publically available AND peer reviewed
methodology/PCR that is compliant with ISO 21930 or EN 15804.
4 N
0
Select building type: All others
*see guidance tab Points 20 12
Credits achieved 3
(M) Source LCA data quality - Verification*
Majority of individual materials/products in the tool are
assessed using:
Score:-
LCA data/data of unknown level of verification 0 N 0
Verified/peer reviewed LCA data 6 Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 scheme
Verified/peer reviewed LCA data AND majority of EPD used (manufacturer or trade 10 N
association) are verified to ISO 14025, ISO 21930 or EN 15804 0
*see guidance tab Points 10 6
Total points 70 54
Discounting for future emissions (e.g. to adjust for future changes to energy supply N
(fuel mix, technology etc.))
Mandatory
Maximum
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:-
Embodied carbon (CO2e) M 2
Embodied water OR waste processing 2
AND any two additional indicators 4
Points 8
(M) Output Life stage(s) available (for all indicators selected) Score:-
Cradle to Gate total 2
Cradle to Gate total AND End of Life 4
Cradle to Grave total 6
Cradle to Grave total WITH operational energy (reported separately) 8
Cradle to grave with separate life stage reporting* to:- 12
a. Product stage
b. Construction process stage
c. Use stage (with operational energy reported separately)
d. End of life
*see guidance tab Points 12
(M) Assessment level(s). Life cycle impact comparisons possible (and
made) at the: Sum:-
Elemental level* 4
Whole Building Level 4
Whole building level; with user product-level specification (e.g. thickness, service life) 2
and reporting aligned to (the current version of) EN 15978.
*see guidance tab Points 10
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4
compliant with (the current version of) ISO 14040 & ISO 14044
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of):
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4
EN 15804 4
Are all assessed to the same publically available AND peer reviewed 4
methodology/PCR that is compliant with ISO 21930 or EN 15804.
*see guidance tab Points 20
Total points 70
Discounting for future emissions (e.g. to adjust for future changes to energy
supply (fuel mix, technology etc.))
Mandatory Met
Mandatory
(if present)
Present in
building?
tool?
Y 1 Internal windows Y
Y Building Services:-
Heat Source, Space Heating, Air Conditioning, Ventilation Y
Y
Communication, Security and Control Systems Y
10 Electrical Installations Y
Y Sanitary Installations Y
1
10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y
Y Total Points
1
Y
1
Score:-
N 0
Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 schem
Y
1
10
70
Y
N
N
0-60
kWh/year
kWh/year
kWh/year
kWh/year
enter quantity
Cells that
Cells that are
are white
white with
withaa black
black border
border require
require the
the user
user to
to input
input information,
information,
theavailable
the available options
options or
or entering
entering the
therequired
requireddata.
data.
Cells that
Cells that are
are light
light grey
grey (with/without
(with/without black
black border)
border) contain
contain information
information for
for th
th
assessment?
automated calculation.
automated calculation. They
They do
do not
not require
require the
the user
user to
to input
input or
or select
select data.
data.
Included in
Maximum
0.50 Y
0.50 Y
2.00 Y
1.00 Y
1.00 Y
1.00 Y
1.00 Y
1.00 Y
0.50 Y
1.00 Y
0.50 Y
30.0 30.0
100.0%
All others
5 + Exemplary
r)r) contain
contain information
information for
for the
the user
user and/or
and/or
ser
er toto input
input or
or select
select data.
data.
BREEAM International New Construction 2016 Mat 01 Calculator
Mandatory
Maximum
Note: where 'M' is indicated against a section heading,
at least one item must be indicated 'Y'.
Output Indicators available Sum:-
Embodied carbon (CO2e) M 2
Embodied water OR waste processing 2
AND any two additional indicators 4
Points 8
(M) Output Life stage(s) available (for all indicators selected) Score:-
Cradle to Gate total 2
Cradle to Gate total AND End of Life 4
Cradle to Grave total 6
Cradle to Grave total WITH operational energy (reported separately) 8
Cradle to grave with separate life stage reporting* to:- 12
a. Product stage
b. Construction process stage
c. Use stage (with operational energy reported separately)
d. End of life
*see guidance tab Points 12
(M) Assessment level(s). Life cycle impact comparisons possible (and
made) at the: Sum:-
Elemental level* 4
Whole Building Level 4
Whole building level; with user product-level specification (e.g. thickness, service life) 2
and reporting aligned to (the current version of) EN 15978.
*see guidance tab Points 10
Are each assessed to any publicly available AND peer reviewed methodology/PCR 4
compliant with (the current version of) ISO 14040 & ISO 14044
Are each assessed to any publically available AND peer reviewed methodology/PCR
that is compliant with (the current version of):
ISO 21930 (may be awarded 'Y' if EN 15804 is awarded 'Y') 4
EN 15804 4
Are all assessed to the same publically available AND peer reviewed 4
methodology/PCR that is compliant with ISO 21930 or EN 15804.
*see guidance tab Points 20
Total points 70
tor
Mandatory Met
Mandatory
(if present)
Present in
building?
tool?
Y 1 Internal windows Y
Y Building Services:-
Heat Source, Space Heating, Air Conditioning, Ventilation Y
Y
Communication, Security and Control Systems Y
10 Electrical Installations Y
Y Sanitary Installations Y
1
10 Landscaping
Hard Landscaping, Roads, Paths and Pavings Y
Y Total Points
1
Y
1
Score:-
Y 1
Y 1 Note: Please see guidance tab to confirm credits achieved when using BREEAM-NOR 2016 schem
Y
1
10
70
Cells that
Cells that are
are white
white with
withaa black
black border
border require
require the
the user
user to
to input
input information,
information,
theavailable
the available options
options or
or entering
entering the
therequired
requireddata.
data.
Cells that
Cells that are
are light
light grey
grey (with/without
(with/without black
black border)
border) contain
contain information
information for
for th
th
assessment?
automated calculation.
automated calculation. They
They do
do not
not require
require the
the user
user to
to input
input or
or select
select data.
data.
Included in
Maximum
0.50 Y
0.50 Y
2.00 Y
1.00 Y
1.00 Y
1.00 Y
1.00 Y
1.00 Y
0.50 Y
1.00 Y
0.50 Y
30.0 30.0
100.0%
All others
5 + Exemplary
r)r) contain
contain information
information for
for the
the user
user and/or
and/or
ser
er toto input
input or
or select
select data.
data.
BREEAM International 2016 New Construction Mat 01 Calculator
Version Release Date Description of changes/additions made to the BREEAM International 201
Current version
9.0 5/22/2019 * Inclusion of approved Mat 01 score template for Anavitor/ECO2
Previous versions
8.0 11/5/2018 * Inclusion of approved Mat 01 score template for SBS Building Sustainability
4.0 1/2/2018 * Included points for EN 15804 within Methodology section for 'eToolLCD_IMP
3.0 4/13/2017 * Inclusion of revised score template for One Click LCA (software formerly calle
1.0 5/31/2016 Initial release version of BREEAM International 2016 New Construction Mat 01
Construction Mat 01 Calculator
on of changes/additions made to the BREEAM International 2013 New Construction Mat 01 Calculator
n of revised score template for One Click LCA (software formerly called 360optimi). This rating applies to all users of the software.