1 2 3 4 5 6 7 8

STATIC LOAD TABLE


DISCHARGE FLANGE ITEM MASS (kg). POSITION OF CENTROID (mm).
228 O.D. x 79 I.D. MOTOR 78 X= 0 Y= 1023
4 HOLES DIA 22 ON
A PUMP 235 X= 0 Y= 350 A
191 P.C.D. EQUISPACED
DRIVE
OFF CENTRELINE. COMPONENTS 187 X= 0 Y= 932
Y
TOTAL 500 X= 0 Y= 673
DYNAMIC LOADS FOR FOUNDATIONS ARE NORMALLY CONSIDERED TO
1320 COMPRISE FORCES ACTING ON PUMP FLANGES PLUS UP TO 2,5 TIMES
STATIC LOADS ACTING THROUGH RESPECTIVE CENTROIDS.

ALTERNATIVE POSITIONS OF DISCHARGE AS VIEWED FROM INTAKE FLANGE.


MOTOR PULLEY: DIA 140 x 2SPA
TAPERLOCK BUSH: 2012 x DIA 38
X STANDARD
MOTOR MAKE: WEG
BOTTOM TERMINAL DISCHARGE
B FRAME: D132M B
BOX ENTRY POSITION
POWER: 7,5 kW VEE BELTS: 2 x SPA1400
218 POSITION IS
No. OF POLES: 4 NOT POSSIBLE B A
PUMP PULLEY: DIA 224 x 2SPA

*
149
TAPERLOCK BUSH: 2517 x DIA 42 C K

RUBBER LINED
POSITIONS B & C RECOMMENDED
2 EARTHING LUGS INTAKE FLANGE D G WHEN PUMPING FROTHY PULPS.
370 O.D. x 186 I.D.
E F POSITIONS F & G RECOMMENDED
8 HOLES DIA 23 ON
324 P.C.D. EQUISPACED WHERE COMPLETE DRAINAGE OF PUMP
324 *

4
C
45 OFF CENTRELINE. IS REQUIRED.
C

412
1051 MAX.

262 *
27 *
59

432
25

CLIENT : CRUSHING SERVICES INTERNATIONAL

GLAND WATER FLUSH LOCATION : GOLDFIELDS


D D
CONNECTION RP1 4 /8.
4 LIFTING LUGS EQUIPMENT NAME : ROUGHER FLOTATION TAILS
83 33 * = 483 =
EQUIPMENT No/S. : 16PP32A, 16PP32B, 16PP32C, 16PP32D
406 406 232 191 * 230 535
No. OF ASSEMBLIES : FOUR (4)

980 560 SERIAL No/S. : AU10001408, AU10001409, AU10001410, AU10001411

E WORKS ORDER No/S. : PW000485-27 E


6 HOLES DIA 25 FOR MINIMUM REQUIRED CLEARANCE
M20 ANCHOR BOLTS FOR PUMP DISMANTLING WEIGHT IN KG ALL DIMENSIONS IN MM

OFFICE OF ORIGIN :
AUSTRALIAN ENGINEERING SYDNEY
NOTE:
TITLE
Copyright © Weir Minerals Australia Ltd. 2016
1. DIMENSIONS SHOWN THUS * INCLUDE Weir Minerals Australia Ltd ("the Company") is the owner
COMPRESSION OF WARMAN RUBBER JOINT. SCALE: - of the copyright and all confidential information in this ARRANGEMENT OF 3 C-AHF WITH 7,5 kW MOTOR
drawing.

3 APP: N.R The drawing must not be copied in whole or in part, in


any form or by any means, and the information in it must ZV1 DRIVE DISCHARGE FLANGE POSITION A
F not be disclosed to any person, or used for any purpose F
2 other than the specific purpose for which it has been
CHK: CH.B provided, without the prior written consent of the Company.
1
SHEET SIZE DRAWING No REVISION
0 INITIAL RELEASE 10AUG2016 EDRAV16-00054 M.J CH.B DRN: MADHU.J
REV DESCRIPTION DATE REF NO BY CHK DATE: 10AUG2016 SHEET 1 OF 1 A3 A588807 0
1 2 3 4 5 6 7 8