You are on page 1of 13

Olympian 400 Series

Generating Sets
Features and Benefits
Replacement Complete Lister Range
LPW Series
¾ Replacement for Complete
Lister Engine Range
¾ Last order dates for old
Lister Gensets: April 11
¾ Open order book for new
models : 2nd week April

400 Series
Engine Power Range
Selected Range 10 – 35 kVA

404C-22G2

404C-22G1

403C-15G

0 5 10 15 20 25 30 35 40

kVA
Generating Set Ratings
3 Phase Genset Range

Olympian Model Rating @ 50Hz Rating @ 60Hz


Engine
Prime SBY Prime SBY Prime SBY
P12.5P2 P13.5E2 403C-15 12.5 13.8 15 16.2
P16.5P2 P18E2 404C-22G1 16.5 18 19.4 21.3
P20P2 P22E2 404C-22G2 20 22 22.5 25
- PH22E2 403C-15 NA 22 NA NA
- PH30E2 404C-22G1 NA 30 NA NA
- PH35E2 404C-22G2 NA 35 NA NA
Generating Set Ratings
Single Phase Genset Range

Olympian Model Rating @ 50Hz Rating @ 60Hz


Engine
Prime SBY Prime SBY Prime SBY
P10P2S P11E2S 403C-15 10 11 12 13
P13P2S P14E2S 404C-22G1 13 14 15.5 17
P15P2S P16.5E2S 404C-22G2 15 16.5 18 20
- PH17.5E2S 403C-15 NA 17.5 NA NA
- PH24E2S 404C-22G1 NA 24 NA NA
- PH28E2S 404C-22G2 NA 28 NA NA
Engine Features
• Indirect Injection Cylinder head casting

• Low Noise emissions


Modification of swirl chamber design

• Reduced gaseous
emissions Glow plugs
• EPA Tier II / EU State 2
Compliant

Optimisation of throat area


Engine Features
¾ Reduced noise, Vibration & Harshness
• Bare engine noise - new combustion chamber
design
• Installed noise - Water pump: higher flow
allows reduced speed and hence fan noise
¾ Reduced Smoke
• New combustion chamber design IDI
• EPA Tier2
• Closed Circuit Breathing
¾ Proven low load capability
• 250 hours zero load, no slobber
Generating Set Package
• Robotically welded baseframe on open set
• 8 hour metal fuel tank
• 2 canopy options:
• CAE – G series
• CAL – Vision series (high ambient and
3000rpm)
Control Panel Offerings

LCP0 LCP1 LCP2


Open CAL CAE
LCP0 LCP1 LCP2 Acs4000 Acs2000 LCP0 LCP1 LCP2 Acs4000
1500 Opt Std Opt Opt Std Opt Std Opt Opt
1800 Opt Std Opt Opt Std Opt Std Opt Opt
3000 Opt Std Opt Opt Std NA NA NA NA

Access2000 Access4000
G Series Enclosure
• Distinctive Olympian
design
• Ambient clearance to 35
deg
• 1500 and 1800rpm units
• LCP1, LCP2 and
Access4000
• Previous options still
apply
Vision Enclosure (CAL)
• Higher ambient
capability
• Autostart standard
• Optional single point
lift
• Removable panels
front and rear / lift off
doors
• Integrated changeover
to follow
Generating Set Performance
• 500 hour service interval
• Meet ISO8528-5 Performance
Class 2 Governing
• Max load step 100%
• Noise levels 78dBA @ 1m 20kVA
• Cooling in ambient temperatures
up to 45deg C
• Passes stringent UL2200 rain
ingress testing
Options
• Fixed / adjustable height trailers
• Socket options
• 4 pole circuit breaker
• Earth leakage
• Water heater
• Battery charger
• Future offering of electronic governor