You are on page 1of 3

Design Of Isolated Footing 1 of 3

1 Footing Size Design

Load Pu 560 KN
Design Load P 411 KN

Moment in x dir Mux 4 KN-m


Moment in y dir Muy 5 KN-m

Column size cx 350 mm


cy 350 mm

SBC q 165 KN/sqm

Footing Size required A req 2.49 sqmm

L 1.75 meters
Footing Size Provided
B 1.75 meters
Area Provided A prvd 3.06 meters

Zx 0.89
Zx 0.89

Net upward pressure Nup 141 KNm2

Footing Size OK

2 Slab Design
lx 0.700
ly 0.700

Bending Moment in x dir Mx 52 KN-m


Bending Moment in y dir My 52 KN-m

Concrete fck 20 MPa


Steel fy 415 MPa

Minimum Depth Required dmin 137 274.084362

Depth Provided D 300 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 244 mm

Spacing c/c in mm
Area of Steel
12# 16# 20#
620 sqmm 182 c/c 324 c/c 506 c/c
620 sqmm 182 c/c 324 c/c 506 c/c

Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm


Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
Design Of Isolated Footing 2 of 3

3 One Way Shear along x direction

Vu1 169 KN
ζv 0.395 MPa

ζc 0.362 MPa
Vc1 154 KN

Increase Depth

4 One Way Shear along y direction

Vu1 169 KN
ζv 0.395 MPa

ζc 0.362 MPa
Vc1 154 KN

Increase Depth

5 Two Way Shear


Vu2 572 KN
ζv 0.987 MPa

ks*ζc 1.118 MPa


Vc1 648 KN

Two Way Shear Check OK


Design Of Isolated Footing 3 of 3

L= 1.75 meters

350

350
B= 1.75 meters

300 mm
150 mm

12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c