priliminary design

SLAB:- take bigger slab panel and consider shorter span


d= shorter span /(35 to 42)

d= 4.21/42= 100mm effective depth (d)

overall depth = d + ø/2 +clear cover


(D) total depth

1m = 3.281 ft

1ft = 1/3.281 m

13.5/3.281 4.21m
priliminary design
Beam:- take longest beam
d= shorter span /(12 to 15)

d= 4.11/15 to 4.11 /15 = 274 to 355mm = 350 mm

overall depth = d + ø/2 +clear cover

width b = D/2 to2 D/3

2/3 x 350 =237 = 230 mm


priliminary design
Column:-
Pu = 0.4 Fck (Ag-Asc) + 0.67 Fy Asc

dead load calculation

floor finish load 15.675858 remaining beam depth


partition load 15.675858
slab self weight 39.189645
beam self weight 11.3913441
column self wt 5.600426699 consider dimension
wall load 41.22417784 ht of column 8ft 2 inch
128.7573096

live load calculation


REDUCTION 10% column wt
LL 2kn/sq.m

GF 0 wall load
FF 2X 15.675X0.90 28.21654
SF 2X 15.675X0.80 25.08137
ROOF 1.5X 15.675 23.51379
Asc
FLOOR DEAD LIVE TOTAL
GF 128.7573 28.2165444 156.9739
FF 128.7573 25.0813728 153.8387 Pu = 0.4 Fck (Ag-Asc) + 0.67 Fy
SF 128.7573 23.513787 152.2711
463.0836 903013.084534

FACTORED 694.6254 Ag =

EQ CONS EXTRA 30% 903.0131

ULTIMATE LOAD 903.0131 kN

903013.1 N
4 Fck (Ag-Asc) + 0.67 Fy Asc Asc = 0.8% to 6% take Asc =4%

350-100 area of slab


250 l 12.5 3.809814
b 13.5 4.114599

300x300 Area 15.67586


8.166666666667
8.16667/3.281
total length of beam 13.5/2+11.5/2+13.5/2+13.5/2
2.489078532968

0.3 x0.3x2.489x25

19x lxbxh
19x7.9244x0.11x2.489

4% of Ag
0.04 of Ag

Pu = 0.4 Fck (Ag-Asc) + 0.67 Fy Asc

0.45 x 20x (Ag-0.04Ag)+ 0.67 x 500 x 0.04Ag


26

26/3.281
7.924413