You are on page 1of 8

CS 5500 LOBBY CASH DISPENSER

STANDARD AND FULL HEIGHT


CALL 1-800-999-3600 REAR LOAD - WITH 40mm (1916") CEN I SAFE
L1229
M ETRES
NCHES)
LLI
NI
N MI
ONS I
ONS I
M ENSI
M ENSI
DI
(
DI RD ANGLE
ON
PROJECTI
THI

FRONT - STANDARD HEIGHT FRONT - FULL HEIGHT


SEE PAGES 2 and 3 FOR CS 5500 STANDARD HEIGHT DETAILS SEE PAGES 4 and 5 FOR CS 5500 FULL HEIGHT DETAILS
PAGE 1 OF 8 CE"
A
TERI
THOUT NOTI
GN CRI
ONS AND DESI
SUBJECT TO CHANGE W I
M ENSI
ALL DI
"
676 REV.3
LE NO.177-

REAR - STANDARD HEIGHT REAR - FULL HEIGHT


FI
CS 5500 LOBBY CASH DISPENSER
STANDARD HEIGHT - REAR LOAD
CALL 1-800-999-3600 WITH 40mm (1916") CEN I SAFE

CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE


BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
444 SAFE
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
(1712")
TP-821922-001.
M ETRES
NCHES)

CONSUMER ACCESS DIMENSIONS


HEIGHT DEPTH
LLI

1360mm 135mm
NI

A TOP OF DISPLAY
N MI

(53916") (714")
ONS I

838 SAFE
ONS I

1258mm 95mm
B TOP FUNCTION KEY
M ENSI

9
(49 16") (334")
33"
)
35716"
M ENSI

901

1032mm 118mm
C KEYPAD ("5" KEY)
DI

(4058") (434")
(
(
DI

897mm
D RECEIPT PRINTER 0
5
(35 16")

750mm 9mm
E ActivDispense
(2912") 3
( 8")

1090mm 32mm
F HEADPHONE JACK
(4278") (1716")

1021mm 60mm
G FINGER PRINT READER
RD ANGLE

1 3
(40" 4")
ON

463 (2 8")
PROJECTI

(1814") 918mm 18mm


H CARD READER
(3618") 3
( 4")
THI

PLAN VIEW HEIGHT - FROM BOTTOM OF SAFE


STANDARD HEIGHT TERMINAL DEPTH - FROM FRONT EDGE OF FASCIA

742
(29316")
463
(1814") 577
(2234")

A
PAGE 2 OF 8

B
F

C G

D H
)
561516"

)
1446

561516"
53916"
E
CE"

1360
A

1446
TERI
THOUT NOTI

)
GN CRI

44516"

(
1125

(
850 SAFE
ONS AND DESI

(
SUBJECT TO CHANGE W I

)
33716"
(
M ENSI
ALL DI
"

44
(134")
*
676 REV.3

TYPICAL ACCESS TO LEVELING


838 SAFE
LEGS RANGE 0 - 100mm (31516")
444 SAFE (33")
(2) EACH SIDE OF SAFE
(1712")
LE NO.177-

901
*

(35716")
FRONT VIEW TO COMPLY WITH CEN I
STANDARD HEIGHT TERMINAL LEVELING LEGS ARE NOT SIDE VIEW
TO BE EXTENDED BELOW STANDARD HEIGHT TERMINAL
FI

SAFE BOTTOM
CONDUIT AND JUNCTION BOX
REQUIREMENTS POWER REQUIREMENTS
THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
(218")
1 102mm (4") SQ. X 54mm DP. JUNCTION BOX (ALL BY OWNERS (E.C.) ELECTRICAL (CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER
CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS
CONTRACTOR).
SPECIFIED BELOW.
CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
OWNERS E.C. TO RUN 19mm 3
(4") LIQUID TIGHT FLEX METAL CONDUIT OR 19mm 3
(4") 100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
2 RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. 100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
3 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
19mm (4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ.
X 54mm (218") DEEP JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF POWER POWER TO THE CASH DISPENSER MUST BE A DEDICATED SERVICE AND PROTECTED
3 CABLE PLATE, OR WITH-IN 2710mm (107") IF OPTIONAL EXTENDED LENGTH POWER CORD BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT
IS USED (ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS). BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 15 AMPERES
CONNECTOR SUPPLIED WITH UNIT. STANDARD POWER CORD LENGTH 2210mm (87") FROM
4 SIDE OR REAR OF TERMINAL. OPTIONAL 2710mm (107") EXTENDED LENGTH POWER CORD
200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES

IS AVAILABLE FROM SIDE OR REAR OF TERMINAL. THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
M ETRES

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.


NCHES)

NOTE: THE CS 5500 SYSTEM IS AVAILABLE WITH AN OPTIONAL 300 WATT-HOUR BATTERY BACKUP
JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF POWER CABLE PLATE WHEN
SYSTEM. THIS OPTION PROVIDES FULL SYSTEM POWER DURING SHORT DURATION POWER
USING STANDARD POWER CORD PROVIDED WITH UNIT, OR WITHIN 2710mm (107") OF POWER
OUTAGES AND THEN INITIATES AN ORDERLY SHUTDOWN IF THE POWER DOES NOT RETURN.
CABLE PLATE WHEN USING OPTIONAL EXTENDED LENGTH POWER CORD. LOCATE IN AN
LLI

CONSULT THE SYSTEM OPERATING GUIDE FOR MORE INFORMATION.


EASILY ACCESSIBLE AREA.
NI
N MI

POWER USAGE
ONS I

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW


CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED
A A
ONS I

CONDUIT FOR EXISTING CONSTRUCTION.


MACHINE STATUS
WITH BATTERY
M ENSI

PHYSICAL SECURITY
CHARGING
THE SAFE DOOR FEATURES A POSITIVE RELOCKING DEVICE. ACCESS TO THE SAFE DOOR
M ENSI

IDLE (NO TRANSACTION) 60 WATTS 85 WATTS


IS MANAGED BY AN INSTALLED MECHANICAL OR ELECTRONIC COMBINATION LOCK OR
LOCKS THAT ARE UL CERTIFIED, VDS CERTIFIED CLASS 1 OR CLASS 2, AND/OR TRANSACTION (DISPENSE
DI

95 WATTS 120 WATTS


EN-1300 CERTIFIED CLASS A OR CLASS B DEPENDING ON THE SYSTEM CONFIGURATION. IN PROGRESS)
(

CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION.


DI

CONFIGURATION
ALARM PROTECTION
A ALL-IN-ONE PROCESSOR, MOTORIZED CARD READER, RECEIPT PRINTER, AND
CEN RATED SAFES EQUIPPED WITH A SAFE DOOR SWITCH BY DEFAULT. ADDITIONAL 4 CASSETTE DISPENSER.
ALARM AND SENSOR PACKAGES ARE AVAILABLE TO MONITOR FOR VARIOUS ATTACK
THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE
VECTORS. CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION. CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.
VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.

SIGNAL CABLE RUN CONSTRAINTS


HEAT OUTPUT CONFIGURATION
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL
205 BTU/HR IDLE
CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. A
325 BTU/HR DISPENSING
SEPARATION FROM OTHER CABLES WITH BATTERY 290 BTU/HR IDLE
A
CHARGING 410 BTU/HR DISPENSING
TYPE OF ELECTRICAL RUN BELOW 2 KVA 2-5 KVA ABOVE 5 KVA
RD ANGLE
ON

FLUORESCENT, NEON OR INCANDESCENT OPERATING ENVIRONMENT


127mm (5") 127mm (5") 127mm (5")
PROJECTI

LIGHTING FIXTURES SAFE LOCATION 0°C TO 50°C (32°F TO 122°F)*


*(REQUIRES SOLID STATE DRIVE (SSD) IN ActivCore PROCESSOR.
UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT 127mm (5") 305mm (12") 610mm (24")
IF A HARD DISK DRIVE (HDD) DRIVE IS USED, THE MAX OPERATING

UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT TEMPERATURE IS REDUCED TO 40°C ( 104°F)


1 152mm (6") 305mm (12")
64mm (2 2")
THI

WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT RELATIVE HUMIDITY (NON-CONDENSING )


20 TO 80% AT 32º C (90º F),
POWER LINES IN GROUNDED CONDUIT WITH SIGNAL 30mm (1316") 76mm (3") 152mm (6") 20 TO 55% AT 40º C (104º F)
CABLES IN GROUNDED CONDUIT

WEIGHT OF UNIT (STANDARD HEIGHT)


SIGNAL CABLE INSTALLATION CONSTRAINTS
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND CEN I --------------------------------- 465kg (1025 LBS.) APPROXIMATE.
LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT
WITHSTAND AS MUCH STRAIN IN INSTALLATION. ACTUAL WEIGHT OF THE TERMINAL WILL DEPEND ON THE
CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS
463
(1814")
35 79 79 35
901
(138") (318") (318") (138")
(35716")
)
278"
73
(

AIR VENTS
PAGE 3 OF 8

125 256
(478") (10116")

AIR VENTS
)
138"
36

1
(

)
561516"
1446
)
CE"

50516"
A
TERI

1278
THOUT NOTI

STANDARD LENGTH POWER


GN CRI

(
)

CORD 2210mm (87") or


44516"
(

1125

850 SAFE

OPTIONAL EXTENDED
1 LENGTH 2710mm (107")
ONS AND DESI

)
(
SUBJECT TO CHANGE W I

FROM SIDE OF TERMINAL.


33716"
)
4214"
1073

4
(
M ENSI
ALL DI
"

70 70
3
(234")
676 REV.3

TYPICAL ACCESS TO LEVELING 588 (2 4")


444 SAFE
LEGS RANGE 0 - 100mm (31516") (2318")
55
(1712") (2) EACH SIDE OF SAFE
399
(2316")
(151116") 38
LE NO.177-

REAR VIEW 838 SAFE (112")


STANDARD HEIGHT TERMINAL TO COMPLY WITH CEN I
(33")
LEVELING LEGS ARE NOT
TO BE EXTENDED BELOW
SAFE BOTTOM
SIDE VIEW
FI

STANDARD HEIGHT TERMINAL


CS 5500 LOBBY CASH DISPENSER
FULL HEIGHT - REAR LOAD

CALL 1-800-999-3600
WITH 40mm (1916") CEN I SAFE

CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE


BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
444 SAFE
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
(1712")
TP-821922-001.
M ETRES
NCHES)

CONSUMER ACCESS DIMENSIONS


HEIGHT DEPTH
LLI

1360mm 135mm
NI

A TOP OF DISPLAY
N MI

(53916") (714")
ONS I
ONS I

1258mm 95mm
B TOP FUNCTION KEY
M ENSI

9
(49 16") (334")
33"
838
)
35716"
M ENSI

901

1032mm 118mm
C KEYPAD ("5" KEY)
DI

(4058") (434")
(
(
DI

897mm
D RECEIPT PRINTER 0
5
(35 16")

750mm 9mm
E ActivDispense
(2912") 3
( 8")

1090mm 32mm
F HEADPHONE JACK
(4278") (1716")

1021mm 60mm
G FINGER PRINT READER
RD ANGLE

1 3
(40" 4")
ON

463 (2 8")
PROJECTI

(1814") 918mm 18mm


H CARD READER
(3618") 3
( 4")
THI

PLAN VIEW HEIGHT - FROM BOTTOM OF SAFE


FULL HEIGHT TERMINAL DEPTH - FROM FRONT EDGE OF FASCIA

742
(29316")

463 95 350
(1814") (334") (131316")

)
334"
A

95
AIR VENTS

(
PAGE 4 OF 8

B
F

)
161316"
427
C G

(
D H
)
561516"

)
1446

561516"
E
CE"
A

1446
TERI
THOUT NOTI

(
GN CRI

(
850 SAFE
ONS AND DESI
SUBJECT TO CHANGE W I

)
33716"
(
M ENSI
ALL DI
"

44
(134")
*
676 REV.3

TYPICAL ACCESS TO LEVELING


838
LEGS RANGE 0 - 100mm (31516")
444 SAFE (33") SAFE
(2) EACH SIDE OF SAFE
(1712")
901
LE NO.177-

(35716")
FRONT VIEW TO COMPLY WITH CEN I
FULL HEIGHT TERMINAL LEVELING LEGS ARE NOT SIDE VIEW
TO BE EXTENDED BELOW FULL HEIGHT TERMINAL
FI

SAFE BOTTOM
CONDUIT AND JUNCTION BOX
REQUIREMENTS POWER REQUIREMENTS
THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
(218")
1 102mm (4") SQ. X 54mm DEEP. JUNCTION BOX (ALL BY OWNERS (E.C.) ELECTRICAL (CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER
CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS
CONTRACTOR).
SPECIFIED BELOW.
CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
OWNERS E.C. TO RUN 19mm 3
(4") LIQUID TIGHT FLEX METAL CONDUIT OR 19mm 3
(4") RIGID
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
2 CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. 100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
3 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ.

3 X 54mm
1
(2 8") DEEP JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF POWER POWER TO THE CASH DISPENSER MUST BE A DEDICATED SERVICE AND PROTECTED
CABLE PLATE, OR WITH-IN 2710mm (107") IF OPTIONAL EXTENDED LENGTH POWER CORD BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT
IS USED (ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS). BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 15 AMPERES
CONNECTOR SUPPLIED WITH UNIT. STANDARD POWER CORD LENGTH 2210mm (87") FROM
4 SIDE OR REAR OF TERMINAL. OPTIONAL 2710mm (107") EXTENDED LENGTH POWER CORD
200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES

IS AVAILABLE FROM SIDE OR REAR OF TERMINAL. THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
M ETRES

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.


NCHES)

NOTE: POWER USAGE


JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF POWER CABLE PLATE WHEN
USING STANDARD POWER CORD PROVIDED WITH UNIT, OR WITHIN 2710mm (107") OF POWER
CABLE PLATE WHEN USING OPTIONAL EXTENDED LENGTH POWER CORD. LOCATE IN AN A A
LLI

EASILY ACCESSIBLE AREA. MACHINE STATUS


NI

WITH BATTERY
N MI

CHARGING
ONS I

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW


CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED IDLE (NO TRANSACTION) 60 WATTS 85 WATTS
ONS I

CONDUIT FOR EXISTING CONSTRUCTION.


TRANSACTION (DISPENSE
95 WATTS 120 WATTS
IN PROGRESS)
M ENSI

PHYSICAL SECURITY
THE SAFE DOOR FEATURES A POSITIVE RELOCKING DEVICE. ACCESS TO THE SAFE DOOR
M ENSI

IS MANAGED BY AN INSTALLED MECHANICAL OR ELECTRONIC COMBINATION LOCK OR CONFIGURATION


LOCKS THAT ARE UL CERTIFIED, VDS CERTIFIED CLASS 1 OR CLASS 2, AND/OR
A ALL-IN-ONE PROCESSOR, MOTORIZED CARD READER, RECEIPT PRINTER, AND
DI

EN-1300 CERTIFIED CLASS A OR CLASS B DEPENDING ON THE SYSTEM CONFIGURATION. 4 CASSETTE DISPENSER.
(

CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION.


DI

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE
CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.
ALARM PROTECTION VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.

CEN RATED SAFES EQUIPPED WITH A SAFE DOOR SWITCH BY DEFAULT. ADDITIONAL
ALARM AND SENSOR PACKAGES ARE AVAILABLE TO MONITOR FOR VARIOUS ATTACK HEAT OUTPUT CONFIGURATION
VECTORS. CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION. 205 BTU/HR IDLE
A
325 BTU/HR DISPENSING
WITH BATTERY 290 BTU/HR IDLE
SIGNAL CABLE RUN CONSTRAINTS A
CHARGING 410 BTU/HR DISPENSING
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL
CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. OPERATING ENVIRONMENT
SAFE LOCATION 0°C TO 50°C (32°F TO 122°F)*
SEPARATION FROM OTHER CABLES
*(REQUIRES SOLID STATE DRIVE (SSD) IN ActivCore PROCESSOR.
IF A HARD DISK DRIVE (HDD) DRIVE IS USED, THE MAX OPERATING
TYPE OF ELECTRICAL RUN BELOW 2 KVA 2-5 KVA ABOVE 5 KVA
RD ANGLE

TEMPERATURE IS REDUCED TO 40°C ( 104°F)


ON

FLUORESCENT, NEON OR INCANDESCENT


127mm (5") 127mm (5") 127mm (5") RELATIVE HUMIDITY (NON-CONDENSING )
PROJECTI

LIGHTING FIXTURES
20 TO 80% AT 32º C (90º F),
UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT 127mm (5") 305mm (12") 610mm (24") 20 TO 55% AT 40º C (104º F)

UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT


64mm (212") 152mm (6") 305mm (12") WEIGHT OF UNIT (FULL HEIGHT TERMINAL)
THI

WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT


CEN I --------------------------------- 475kg (1048 LBS.) APPROXIMATE.
POWER LINES IN GROUNDED CONDUIT WITH SIGNAL 30mm (1316") 76mm (3") 152mm (6")
CABLES IN GROUNDED CONDUIT
ACTUAL WEIGHT OF THE TERMINAL WILL DEPEND ON THE
CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS
SIGNAL CABLE INSTALLATION CONSTRAINTS
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND
LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT
WITHSTAND AS MUCH STRAIN IN INSTALLATION. 901
(35716")

463 742
(1814") (29316")
AIR
350 95
VENTS
)
278"

(131316") (334")
73
(

)
334"
95
(
PAGE 5 OF 8

)
161316"

89
427

(312")
286 1
(

(1114")

AIR VENTS
)
138"

3
36

)
(

561516"
1446
)
50516"
CE"
A

1278
TERI
THOUT NOTI

STANDARD LENGTH POWER

(
GN CRI

CORD 2210mm (87") or


5518"
(

1400

850 SAFE

1 OPTIONAL EXTENDED
LENGTH 2710mm (107")
ONS AND DESI

)
(
)

33716"
SUBJECT TO CHANGE W I

FROM SIDE OF TERMINAL.


341316"
884

4
(
M ENSI
ALL DI

2
"

70 70
3
(234")
676 REV.3

TYPICAL ACCESS TO LEVELING 588 (2 4")


444 SAFE
LEGS RANGE 0 - 100mm (31516")
(2318")
(1712") (2) EACH SIDE OF SAFE 55
399
(2316")
(151116") 38
LE NO.177-

REAR VIEW (112")


838 SAFE
FULL HEIGHT TERMINAL TO COMPLY WITH CEN I
LEVELING LEGS ARE NOT (33")
TO BE EXTENDED BELOW
SAFE BOTTOM SIDE VIEW
FI

FULL HEIGHT TERMINAL


CS 5500 LOBBY CASH DISPENSER
STANDARD AND FULL HEIGHT - REAR LOAD
CALL 1-800-999-3600 WITH 40mm (1916") CEN I SAFE

CS 5500 SERVICE AREA


1018
(40116")

NOTE: 339 444 235

SERVICE AREAS SHOWN ARE TYPICAL FOR BOTH (13516") (1712") (914")
THE STANDARD HEIGHT AND FULL HEIGHT VARIANTS
OF THE 5500 RL CASH DISPENSER TERMINAL
M ETRES
NCHES)

)
3278"
)
LLI

3358"

835
855
NI
N MI
ONS I

(
(
ONS I

)
M ENSI

)
16"

16"
20

20
M ENSI

13

13
(

(
DI
(
DI

250 146

)
13716"
(91316") (534")

342
REQUIRED MINIMUM SERVICE AREA
89 89

)
(312") (312")

31"
788
)

)
35716"

3512"
ALL ELECTRICAL AND DATA CABLES

901

(
901

152
6"
MUST ENTER UNIT IN THIS AREA

(
(
NOTE:
SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR
RD ANGLE

350
ON

INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE


(1334")
PROJECTI

)
INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION

514"
133
AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE

(
RECOMMENDED AREA MAY RESULT IN AN INCREASE IN
INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD NIXDORF
THI

)
8"
INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS.
16

)
2912"
5

749
(
)
2414"
616

(
(

429 463 180


(1678") (1814") (7116")

1072
(42316")

PLAN VIEW
PAGE 6 OF 8

( REQUIRED MINIMUM SERVICE AREA )

HEIGHT OF SPACE IN FRONT AND


REAR OF TERMINAL SHOULD ALLOW
A PERSON TO STAND AND SERVICE
THE TERMINAL

616 901 855


(2414") (35716") (331116")
CE"
A
TERI
THOUT NOTI
GN CRI
ONS AND DESI
SUBJECT TO CHANGE W I
M ENSI

ABLE

NAL
NAL
ALL DI

VARI

GHT TERM I

)
64916"
GHT TERM I

1640
"

(
FULL HEI
STANDARD HEI
676 REV.3
LE NO.177-

SIDE VIEW
FI

(REQUIRED MINIMUM SERVICE AREA )


CS 5500 LOBBY CASH DISPENSER
STANDARD AND FULL HEIGHT - REAR LOAD
CALL 1-800-999-3600 WITH 40mm (1916") CEN I SAFE

REQUIRED MINIMUM SERVICE AREA


M ETRES

ALL ELECTRICAL AND DATA CABLES


NCHES)

MUST ENTER UNIT IN THIS AREA


LLI
NI
N MI

2584
ONS I

(10134")
ONS I
M ENSI

339 444 339 444 339 444 235


M ENSI

(13516") (1712") (13516") (1712") (13516") (1712") (914")


DI
(
DI

)
3278"
)
3358"

835
855

(
(

)
16"

16"
20

20
13

13
RD ANGLE

(
ON
PROJECTI

250 146
)
13716"

(91316") (534")
342
THI

89 89
(

)
(312") (312")

31"
788
)

)
35716"

3512"
)

901

(
901

152
6"
(

(
(

350
(1334")

)
514"
133
(
)
8"
16

)
2912"
5

749
(
)
2414"
616

(
PAGE 7 OF 8

429 463 320 463 320 463 180


(1678") (1814") (1258") (1814") (1258") (1814") (7116")

2638
(10378")
CE"
A
TERI
THOUT NOTI

PLAN VIEW - ADJACENT UNITS


GN CRI

(REQUIRED MINIMUM SERVICE AREA)


ONS AND DESI

NOTE:
SUBJECT TO CHANGE W I

SERVICE AREAS SHOWN ARE TYPICAL FOR BOTH


THE STANDARD HEIGHT AND FULL HEIGHT VARIANTS
OF THE 5500 RL CASH DISPENSER TERMINAL
M ENSI
ALL DI
"
676 REV.3
LE NO.177-
FI
444 SAFE

(1712")
NOTES:
SECURELY ANCHORING THE TERMINAL TO THE FLOOR:
83 278 FOR PROPER SECURITY, IT IS REQUIRED THAT THE TERMINAL SAFE BE SECURED TO THE
(314") (101516") FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE
ANCHORING METHOD FOR THE TERMINAL.
NOTE:
TO COMPLY WITH THE EUROPEAN STANDARD EN 1143-1 REGULATIONS,
1 1 ANCHORING A CEN SAFE TO A WOOD FLOOR IS NOT PERMITTED. A CEN
SAFE CAN ONLY BE ANCHORED TO A CONCRETE OR STEEL FLOOR.

M20 ANCHOR BOLTS PROVIDED BY DIEBOLD NIXDORF MEETS/EXCEEDS THE FOLLOWING


CEN ANCHORING STRENGTH REQUIREMENTS WHEN PROPERLY INSTALLED:
CEN I, II & III: 50 kN (PULLOUT FORCE)
CEN IV: 100 kN (PULLOUT FORCE)
M ETRES
NCHES)

)
ANCHORING SAFE TO CONCRETE FLOORS:

112"
38
838 SAFE

THE TERMINAL MUST BE ANCHORED TO A CONCRETE FLOOR OR CONCRETE BASE TO MEET CEN
)

(
2334"

REQUIREMENTS. DIEBOLD NIXDORF WILL PROVIDE (4) M20 OR 19mm 3


603

(4") ANCHOR BOLTS THAT


LLI

ARE 203mm (8") LONG FOR PROPERLY SECURING THE UNIT. THE CONCRETE FLOOR/BASE
NI

33"

CABLE ENTRY
(
N MI

OPENING MUST BE A MINIMUM OF 102mm (4") THICK FOR THE ANCHOR BOLT TO BE EFFECTIVE
ONS I

)
(

16"
(SEE NOTE) (THERE IS NO LIMIT FOR MAXIMUM THICKNESS). ANCHOR BOLTS MUST BE USED IN ALL

658
ONS I

AVAILABLE SAFE ANCHOR HOLES.

15
25
M ENSI

ANCHORING SAFE TO STEEL FLOORS:

(
2
M ENSI

TERMINALS INSTALLED ON STEEL FLOORS CAN ALSO BE SECURED BY A MACHINE-THREADED

)
151116"
NUT AND BOLT METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH
DI

399
SUPPORTING STEEL POSTS OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY,
(

THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED REINFORCEMENT PLATE


DI

1 1

(
918"
INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL STRENGTH. THE STEEL

232
BACKING PLATE THICKNESS MUST BE AT LEAST 13mm 1
(2"). THE MACHINE-THREADED NUT
)

(
518"

)
130

16"

AND BOLT MUST BE USED IN ALL AVAILABLE ANCHOR HOLES.


90
(

CEN I SAFES:
3
(

DIEBOLD NIXDORF TERMINALS WITH CEN I SAFES ARE EQUIPPED WITH LEVELING LEGS
222 (FOR TRANSPORTATION PURPOSES ONLY) WHICH MUST BE RETRACTED ABOVE THE BOTTOM
(834") OF THE SAFE ALLOWING IT TO SIT DIRECTLY ON THE FLOOR/BASE. THE OWNER’S GENERAL
404 CONTRACTOR MUST PROVIDE A SMOOTH AND LEVEL AREA BELOW SAFE SO IT CAN BE
INSTALLED PLUMB AND LEVEL. THIS WILL FACILITATE PROPER ANCHORING OF THE SAFE TO
20 (151516") 20 THE CONCRETE FLOOR/BASE.
RD ANGLE
ON

13 13
( 16") ( 16")
PROJECTI

PLAN/SECTION CEN I SAFE FLOOR


THI

1-ANCHORING HOLES 2-SNAP-OFF DETECTOR


(4) 45mm (134") RECESS DIAMETER (1) 65mm (2916") RECESS DIAMETER
11
18mm ( 16") RECESS DEPTH 28mm (118") RECESS DEPTH

25.4mm (1") THROUGH-HOLE-DIAMETER 25.4mm (1") THROUGH-HOLE-DIAMETER

NOTE: 29mm (118") DIA. HOLE FOR


SAFE FLOOR DETAILS SHOWN ARE TYPICAL FOR BOTH ALARM CABLES (SIDE ENTRY)
THE STANDARD HEIGHT AND FULL HEIGHT VARIANTS
OF THE 5500 RL CASH DISPENSER TERMINAL

OPENINGS FOR POWER


CORD AND DATA CABLES
(SIDE ENTRY)
PAGE 8 OF 8

POWER CABLE PLATE


CABLE ENTRY NOTE:
ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH A CABLE ENTRY OPENING ON THE
SIDE OF THE SAFE. CABLES ENTERING THE CASH DISPENSER PASS THROUGH THE POWER
CABLE PLATE ATTACHED TO THE EXTERIOR SIDE WALL OF THE SAFE AND THROUGH A
RESTRICTOR BRACKET ATTACHED ON THE INTERIOR SIDE WALL OF THE SAFE AT THE CABLE
ENTRY OPENING. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SAFE AS VIEWED
FROM THE REAR OF THE CASH DISPENSER.
CE"
A
TERI
THOUT NOTI
GN CRI
ONS AND DESI
SUBJECT TO CHANGE W I
M ENSI
ALL DI
"
676 REV.3
LE NO.177-
FI

You might also like