Professional Documents
Culture Documents
in construction
culminal m 6030 pf
an innovative solution for construction
michael zwanzig
application specialist
culminal m 6030 pf
an innovative solution for construction
• sufficient water retention is the key to achieve crack
free setting!
• higher temperature has great influence on water
retention. most of the commonly used ce´s have low
flocculation temperatures leading to loss of water
facts retention especially at elevated temperatures
• the higher the fines content, the higher is the
necessary water demand finally leading to increased
ce-dosage
• crack formation
• poor workability
poor water
• short ot
retention often
• short pot life/workability time
results in…
• no real setting, just “burning” on substrate
• adhesion problems
comparison of wrv performance
98 MC*
96
94
MHPC
water retention (%)
92
90
MHEC HS
88
86
84 MHEC
82
80 M 6030 PF
20 25 30 35 40 45 50 55 60
temperature (°C)
relations of wrv performance
99 15000mPas
95
25000mPas
93 high tendency
of crack formation
91
40000mPas
89
crack formation
87
70000mPas
85
0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55
ce dosage (%)
relations of wrv performance
wrv - relations
0.8 binder - water factor- ce dosage 60
0.7
50
0.6
0.4 30
0.3
20
0.2
10
0.1
0 0
10 15 20 25 30 35 40 50 70
binder content (%)
relations of wrv performance
wrv - relations
binder-water factor-ce dosage
100 0.8
99 0.7
98 0.6
97 0.5
ce dosage (%)
wrv (%)
96 0.4
95 0.3
94 0.2
93 0.1
92 0
10 15 20 25 30 35 40 50 70
98,5% 99,0%
almost no loss of
performance at 40 °C
water retention value
according to our house method
98,0% 98,5%
water retention at
workability
40°C
water retention at
stickiness to tools
20°C
benefits of culminal m 6030 pf
recommended
• skim coat, dosage range 0.20 – 0.50%
target applications
suitable
• renders, dosage range 0.08 – 0.15%
workability
paste stability
abrasion resistance
crack formation
poor water
retention resulting in
worse adhesion !
14
photos – cracking
cracking as lack
of poor water
retention!
15
photos – sanding
- customer data
18
skim coat testing
ce dosages
0.18 – 0.4%
temperature tested
20°C, 40°C
19
skim coat 1
skim coat 1
comparison 20 & 40°C benchmark 2
95.55
98.96
MHEC 40000PF
98.64
40 98.85
99.03 benchmark 1
98.88
99
C 8367
temperature °C
98.25
99.1
C 8381
98.75
99.16
20 Culminal M6030PF - 20%
99.18
99.15
94.02
95.21 benchmark 1
40 95.09
96.05
MHEC 40000PF
97.06
temperature °C
97.59
C 8367
93.52
96.89
C 8381
97.76
20 97.42
97.96
Culminal M6030PF - 10%
98.39
98.44
Culminal M6030PF
84 86 88 90 92 94 96 98 100
WRV (%)
21
skim coat 3
skim coat 3
comparison 20 & 40°C
benchmark 2
92.86
94.32
96.66 benchmark 1
40 95.44
95.73
MHEC 40000PF
97.86
temperature °C
98.07
C 8367
95.64
97.33
C 8381
97.62
20 97.36
97.52
Culminal M6030PF - 10%
97.99
98.16
Culminal M6030PF
90.00 91.00 92.00 93.00 94.00 95.00 96.00 97.00 98.00 99.00
WRV (%)
22
disclaimer
The information contained in this presentation and the various products described are intended for use only by persons having technical skill
and at their own discretion and risk after they have performed necessary technical investigations, tests and evaluations of the products and
their uses. This material is for informational purposes only and describes the scientific support for the use of the products described herein as
an ingredient intended to enhance performance of an end product. Certain end uses of these products may be regulated pursuant to rules
governing medical devices or other regulations governing drug uses. It is the purchaser’s responsibility to determine the applicability of such
regulations to its products. While the information herein is believed to be reliable, we do not guarantee its accuracy and a purchaser must
make its own determination of a product’s suitability for purchaser’s use, for the protection of the environment, and for the health and safety
of its employees and the purchasers of its products.
Neither Ashland nor its affiliates shall be responsible for the use of this information, or of any product, method, formulation, or apparatus
described in this brochure. Nothing herein waives any of Ashland’s or its affiliates’ conditions of sale, and no statement, information and data
is to be taken as a guarantee, an express warranty, or an implied warranty of merchantability or fitness for a particular purpose, or
representation, express or implied, for which Ashland and its affiliates assume legal responsibility. We also make no warranty against
infringement of any patents by reason of purchaser’s use of any information, product, method or apparatus described in this presentation.
The testing information (the “Testing Information”) has been gratuitously provided by Ashland. The Testing Information is based on many
factors beyond Ashland’s control, including but not limited to, the conditions prevailing when the testing was conducted, and in some
cases, is based on data generated with development samples of the Active Ingredient. Although it is intended to be accurate, ASHLAND
DISCLAIMS ANY AND ALL LIABILITY, EITHER EXPRESS OR IMPLIED. The Testing Information is confidential or proprietary to Ashland, and may not,
except as provided below, be disclosed to any third party. You may not make commercial use of the Testing Information, or make claims
with respect to your products based the Testing Information, without the written agreement with Ashland covering such use.