Professional Documents
Culture Documents
Table of Contents
p 2, 3 Introduction
p 4 to 7 Getting Started
p 8, 9 Displays and Functions
p 10 to 12 Change the Settings
p 13 to 19 Operating from Your PC
p 20 to 23 Troubleshooting
INTRODUCTION
ATTENTION!
The Remote Monitor RM-1000 is a device that provides remote management and control of the AIRDOLPHIN.
☛ Please note the following:
● Zephyr Corporation holds no responsibility for accidents or damages that may occur as a result of disregarding
the procedures and warnings described in this manual.
● Zephyr Corporation holds no responsibility for any attempts to modify the device.
● Zephyr Corporation holds no responsibility for accidents or damages that may occur as a result of improper
installation, use, or attempts to modify the device.
☛ The specifications are subject to change without prior notice.
☛ Refer to the owner’s manual for instructions on how to use the AIRDOLPHIN.
☛ The following information provided throughout his manual is not public information. It is provided just for
reference: current power generation displayed in watt (W), power generation displayed in kilo watts per power (kWh),
wind direction, stored power displayed in voltage (V), and temperature displayed in degree (℃).
Safety Instructions (Read and understand these entire instructions before proceeding.)
This symbol indicates information that could result in death or server injury if the instruction is
ignored. It is used for information of a highly dangerous and/or urgent nature.
This symbol indicates information that could result in death or server injury if the instruction is
ignored.
This symbol indicates information that could result in server injury or property damage if the
instruction is ignored.
This symbol is intended to draw attention to This symbol indicates instructions that must
Danger/Warning/Caution information. be followed.
2
Stop operating the device immediately if you notice unexpected hazards or severe damages to the device and
connecting peripherals: In such events, contact your local dealer for immediate technical advice. Never try to disassemble
or modify the device on your own.
In case of fire: Disconnect all peripherals such as wind turbines, a wind direction and speed measuring apparatus, and a
temperature measuring apparatus from the device if you detect an impending fire. In such events, contact your local dealer
or Zephyr Corporation for immediate technical advice. Never try to throw water on the fire. Use ABC powder fire
extinguishers to put out the fire
Do not connect the Remote Monitor RM-1000 to any non-designated peripherals or devices: To do so may cause
fire, an electric shock accident, or severe damages to the device and connecting peripherals.
Do not use the device on systems intended to maintain the public health and community infrastructure, such as life
critical medical devices, devices that may lead to personal injury, or computer systems that play an important role
in social and public systems: These devices may need to establish a multilateral system or install an emergency power
backup system, or require other special measures for proper maintenance and control.
Do not attempt to disassemble, repair, or modify the device: To do so may cause injury or accidents, or severe damages
to the device.
Do not use or store the device in places subject to extremely high or low-temperature, or high humidity. To do so
may cause fire accidents, deterioration, or severe or fatal damages to the device.
Do not use or store the device in places subject to direct sunlight or strong artificial light sources: To do so may cause
fire accidents, deterioration, or severe or fatal damages to the device.
Do not use or store the device in places subject to radiant heat: To do so may cause fire accidents, deterioration, or
severe or fatal damages to the device.
Do not use or store the device in places subject to high levels of vibration and/or shock: To do so may cause fire
accidents, deterioration, or severe or fatal damages to the device.
Do not use or store the device in close proximity to spark-generating devices: To do so may cause explosion accidents,
fire accidents, deterioration, or severe or fatal damages to the device.
Do not use or store the device in places subject to dust, salt, or water, or in close proximity to inflammable or
explosive gases: To do so may cause explosion accidents, fire accidents, deterioration, or severe or fatal damages to the
device.
Do not place a water-holding container, such as a vase, on top of the device: Water may be spilt and splashed onto
the device, or seep into the device, leading to fire or electrical shock accidents.
Do not step, stand, or sit on the device: To do so may cause personal injury or accidents.
Do not use the device outside of your country: Note that voltage regulations vary across the countries and using the
device elsewhere may cause smoke or fire. Contact your local dealer in advance if you wish to use the device outside of
your country.
Follow procedures and warnings described in this manual to operate the device: Disregarding the procedures and
warnings may cause accidents or damages.
Do not remove the cover of the device: Trained technicians only are allowed to do so. The removal of the cover on your
own may cause electrical shock accidents or burn.
*When you need repairs or replacement of parts, contact your local dealer.
3
GETTING STARTED
Check to see if all the required items are inside the RM-1000 package.
Item Quantity
1 RM-1000 1
2 DC-output adapter 1
3 AC/DC adapter 1
4 Multi Media Card (MMC) 1
5 Cable cover 2
6 Instruction Manual 1
The RM-1000 is designed for indoor use only. Installation outdoors may lead to severe
damage to it.
4
Connecting the RM-1000
You can connect the RM1000 to various systems. The following illustrations show examples of how you can connect it.
Interfaces
Step 3
Do not connect the Remote Monitor RM-1000 to any non-designated peripherals or devices.
To do so may cause severe damages to the device and connecting peripherals.
If an Multi Media Card that you are using exceeds 1 GB, RM-1000 data cannot be saved on
that card.
- Make sure to connect plus and minus terminals correctly. Otherwise, damage may be
inflicted on the RM-1000 and connecting peripherals.
- Do not use the Ⓒ terminal.
6
Step 6: Cable covers (included as part of the RM-1000 package)
Put the cable covers on both sides of the RM-1000. Pull off the cutoff sections in a direction toward the cable pulling
direction.
Back of the RM-1000 Front side of the RM-1000 Install the covers so the cutoff
The cutoff sections can be
sections are placed on the back
manually pulled off.
of the RM-1000.
Step6: Secure the cable pulling section and put the cable covers.
7
DISPLAYS AND FUNCTIONS
Let’s use the RM-1000. It displays such information as generated wind power, CO2 reduction amount, wind direction and
speed, and temperature. The displayed data can be saved on the Multi Media Card (MMC).
➎
➋
➏
➊ ➌
➐ ➍
➑
F1 F2 F3 F4 F5
① and ② display five-digit figures. When they display five-digit figures, the X10 indicator lights up.
Right side
1. Press the F1 button on the front and the S1 button on the right side together for two seconds.
2. The current power window displays “rtc” to indicate (real time clock).
3. Using the S1 - S4 buttons, set the date and time in the order of the year, month, day, hour, and minutes.
4. When completed, set the F3 switch to the O position (OFF).
5. Turn the F3 switch back to the I position (ON).
Right side
1. Press the F1 button on the front and the S2 button on the right side together for two seconds.
2. The current power window displays “U2”.
3. Using the F1 and F2 buttons, choose the menu that you want to change.
4. Confirm that the Power window indicates the correct RM-1000 menu number.
5. Enter the settings.
6. When completed, set the F3 switch to the O position (OFF).
7. Turn the F3 switch back to the I position (ON).
You can change or reset the following RM-1000 menus. Please press F1 button on the front and S2 button on the right
10
side together for two seconds.
Factory
Menu Number Descriptions Configuration Notes
defaults
The grand total for the AIRDOLPHIN, which is
106 Reset power total. (day/month/grand total) [1]: Reset 0 saved to the AIRDOLPHIN memory, is always
displayed in the Total Power display window.
1. Reset Total
*Reset power total using Menu 106 after the
127 Offset grand total in kWh. 0 - 9999 0
offset.
Set the upper limit of analog output in percent
108 (100%=3Vdc) based on the rpm of the 0 - 100 100
The output range should be within 0 to 3Vdc.
AIRDOLPHIN.
Be sure to set a higher value for Menu 108 than for
Set the lower limit of analog output in percent
2. Analog Menu 109.
1 109 (0%=0Vdc) based on the rpm of the 0 - 100 0
Output*
AIRDOLPHIN.
(See page 12.)
Set the upper limit of the rpm of the
110 0 - 9999 700 Set the upper limit for one of the menus. If you set
AIRDOLPHIN.
the upper limit for both menus, Menu 111 has a
Set the upper limit of the generated power in
111 0 - 9999 200 higher set priority.
watts.
When serially connecting multiple units, set [0] for
2
3. Terminator* Set the terminator in RS-485 serial [0]: OFF all connecting units except for the end unit.
112 1
(See page 12.) communications. [1]: ON *After the setting, you need to pull off the AC/DC
adapter of RM-1000.
[1]: 1 min.
The shorter the interval, the larger the saved data.
[5]: 5 min.
4. Save Data to Set the interval to save the “AVERAGE” data * If you specify [0], data is saved every second.
113 [10]: 10 min. 10
MMC on the Multi Media Card (MMC). Saved data will be quite huge. It is recommended
[15]: 15 min.
that you not specify [0].
[30]: 30 min.
Set the time to activate the Soft mode, in the
114 3 0000
24-hour notation* .
0000 -
Set the time to deactivate the Soft mode, in the If you enter ’2400”, the AIRDOLPHIN keeps
115 3 2359/2400 0000
5. Timer Setting 24-hour notation* . operating in the Soft mode throughout the day.
(See page 12.) Set the time to activate the Stop mode, in the
116 3 0000
24-hour notation* .
0000 -
Set the time to deactivate the Stop mode, in the If you enter ’2400”, the Stop mode is kept active
117 3 2359/2400 0000
24-hour notation* . throughout the day.
Set the time to start analog output, in the If “00:00” is set for Menus 118 and 119, the timer
118 3 0000
6. Set Analog 24-hour notation* . 0000 - setting has no effect.
Output Timer Set the time to stop analog output, in the 2359/2400 If you enter ‘2400’, analog output continues
119 3 0000
24-hour notation* . throughout the day.
Set the time to start operation, in the 24-hour If “00:00” is set for Menus 120 and 121, the timer
120 0000 - 2359 0000
notation. setting has no effect.
7.Set Inverter
Timer Set the time to stop operation, in the 24-hour 0000 - If you enter ‘2400’, the inverter runs throughout the
121 2400
(For Japanese notation. 2359/2400 day if all operating conditions are met.
market only)
Set timer settings specified in Menus 120 and [0]: OR
123 0
121 to work with an external timer. [1]: AND
11
*1: Analog output (to synchronize with the rpm of the AIRDOLPHIN)
Factory default
Max.: 3Vdc
Example Example
*2: Terminator
The termination resistor is inside of RM-1000.It is possible to select the termination ON or OFF. The termination resistor
should be connected to the RM-1000 at the end of the serial connection. It prevents signal reflection, which is caused by the
impedance mismatch. Signal reflection causes signal distortion, which in turn leads to communication errors.
Example
12
OPERATING FROM YOUR PC
You can use the web server function available with the RM-1000 (ZephyrWeb-1000 hereafter) for remote management and
control of the AIRDOLPHIN from your PC.
Preparations (Basic)
When you change the IP address of your PC as instructed in step 3, you cannot connect to
your network or the Internet. To avoid this, change the default IP configuration of the
RM-1000 in step 5 described on page 14.
13
Step 4: Connect your PC to the RM-1000.
Connect the LAN terminal of your PC to the LAN terminal on the right side of the RM-1000 using a commercially
available LAN cable.
There are two types of cables available:
Straight cable: Used to connect your PC to the RM-1000 via a network hub.
Cross cable: Used to connect your PC directly to the RM-1000.
Right side of the RM-1000
LAN terminal
When using a straight cable: Connect the LAN terminal to
the hub’s LAN terminal.
When using a cross cable: Connect the LAN terminal to
the PC’s LAN terminal.
Repeat steps 1 through 4. In step 5, change the factory default IP configuration of the RM-1000 to use the
RM-1000 on your local network.
Apply Setting
This section provides the minimum information on how to access the RM-1000 via a router.
Your choice of router or network configuration may require more setup. Check the router
specifications and ask your system administrator in advance.
You need to prepare a designated router, contract with an Internet service provider, and
obtain a global IP address in advance.
☞ The port number 80 is the default port number for HTTP in most cases. You can use a different port number.
☞ The port number 10001 is set as the default for the RM-1000. To change the port number, you need to change
both the router and RM-1000 port settings.
Connection
15
Starting the ZephyrWeb-1000
Step 2: Enter the URL in the address bar and hit Enter.
You can choose the display language between Japanese and English, and the screen format between standard 4:3 and
widescreen 16:9 aspect ratio.
16
Click ‘Node Address’
17
Using the ZephyrWeb-1000
Let’s use the ZephyrWeb-1000. You can view the following information in the ZephyrWeb-1000 window.
- Functions are basically the same with the RM-1000. (See pages 8 and 9.)
- There are no functional differences between the Japanese and English versions.
⑲
③
⑦ ②
⑥
① ④
⑬ ⑤
⑫
⑨ ⑩ ⑪
⑭ ⑮
⑯ ⑰ ⑱
① Sum of current (momentary) wind power and solar power *The solar power function is only for the Japanese
market.
② Current (momentary) wind power
③ Current (momentary) solar power *The solar power function is only for the Japanese market.
④ AIRDOLPHIN roter RPM
⑤ Output voltage of AIRDOLPHIN (voltage of the battery or capacitor included in the system.)
⑥ The lighted arrow points in the present (momentary) wind direction
⑦ Current (momentary) wind speed
⑧ Current (momentary) temperature (When the thermometer is not connected, the temperature inside of the
AIRDOLPHIN is displayed.)
⑨ Click to display today’s maximum wind speed and its time, today’s average wind speed, this month’s average
wind speed , annual average wind speed and today’s high and low temperatures in a new window.
⑩ Click to display today, yesterday, this month, last month and the grand total of generated power in a new
window.
⑪ Click to display the CO2 reduction amount in relative to the generated power in a new window.
18
⑫ Multi Media Card (MMC) activity indicator. It lights blue when the card is functioning properly and lights red
when an error occurs.
⑬ The operation mode of the Airdolphin is displayed with the three-color LED indicator.
⑭ Click to switch operation modes between Normal and Soft. Enter [root] for the password.
⑮ Click to switch operation modes between Operate and Stop. Enter [root] for the password.
You can switch operation modes of ⑭⑮ when the F4 switch of RM-1000 is set to
Normal and the F5 switch of RM-1000 is set to Operate. (Please refer to page 9.).
.
⑳This area displays ten levels of rainbow in daylight corresponding to operating conditions (the rpm or
generated power) of the AIRDOLPHIN.
This feature synchronizes with the Analog Output function of the RM-1000.
Refer to the RM-1000 menus 108 –111 and 118 - 119 on page 11 for more
information.
⑧ ⑨ ⑩
⑦
⑥
⑤
④
③
② When RPM (or power) reaches 90 % or
① more of the preset upper limit explained
in menus 110 and 111 described on
page 11, the rainbow will reach the
maximum length.
The ZephyreWeb-1000 will automatically be closed when you close the Internet Explorer. To close the application, use one of
the following:
19
TROUBLESHOOTING
If you have other problems or have questions, please contact your local dealer for immediate
technical advice.
20
Saving data on the multi media card (MMC)
A file name example: RM0804XX ‘XX’ stands for the file number( in hexadecimal), which is automatically assigned in
order.
① Zephyr's RM-1000 Data Log, Firmware version:V2366 : Device type and version
② DT|TM : yy/mm/dd|time : e.g. 08/04/01|01:23:45
③ NA : node address : e.g. 23 (in hexadecimal number) < It means 35 in decimal number.>
④ U[g-CO2/kWh] : CO2 point source [g] : e.g. 0.360 < It means 360 grams-CO2/kW.>
⑤ WP[W] : average wind power[W] : e.g. 00001234
⑥ WHPT[Wh] : total wind power[Wh] : e.g. 00123456
⑦ PP[W] : average photovoltaic power[W] : e.g. 00000200*
⑧ PHPT[Wh] : total photovoltaic power[W] : e.g. 00123456*
⑨ WD[deg] : wind direction [360 degrees] : e.g. 251 <This indicates west southwest. (north = 0 degree)>
⑩ WS[m/s] : average wind speed [m/s] : e.g. 12.3
⑪ WM[m/s] : maximum wind speed [m/s] : e.g. 25.6
⑫ RV[rpm] : average revolutions [rpm] : e.g. 1234
⑬ BV[V] : output (battery) voltage [V] : e.g. 25.6
⑭ AT[dC] : temperature [centigrade] : e.g. 024.5
* for the Japanese system only
Maintenance data
The data is intended for service. If trouble or the unexpected occurs, technicians at your local dealer or Zephyr Corporation use it for
troubleshooting.
①FT[dC] ②GT[dC] ③WDTY ④ST+EV ⑤SC ⑥ER+SST ⑦PV[V] ⑧PDTY ⑨P&MST ⑩LGC
21
Specifications
22
Data file format FAT16
Memory capacity Max. 1GB (multi media card exceeding 1 GB cannot be used.)
Selectable from the following:
Data recording interval
Every second (instantaneous)/every 1 min./every 5 min./every 10 min./every 15 min.//every 30 min.
Every second (instantaneous): Approx.11MB/day (5.5 MB file x 2)
Every 1 min: Approx. 6MB/month
Data size per interval
Every 5 min: Approx. 1MB/month
Every 10 min: Approx. 600 kB/month
Dimensions
Cable cover