You are on page 1of 24

Instruction Manual

Remote Monitor RM-1000

Remote Monitor RM-1000 (Ver:2366)

Table of Contents
p 2, 3 Introduction
p 4 to 7 Getting Started
p 8, 9 Displays and Functions
p 10 to 12 Change the Settings
p 13 to 19 Operating from Your PC
p 20 to 23 Troubleshooting
INTRODUCTION

Thank you for purchasing the Remote Monitor RM-1000.


This manual describes specific information on using the Remote Monitor RM-1000. Before using the RM-1000, read this
manual thoroughly and carefully and familiarize yourself with it. Observe the following:
● Read the safety instructions provided in this manual first.
● Keep this manual and the warranty registration certificate in a safe place for future reference.
● Fill out the required items on the warranty registration certificate.

ATTENTION!
The Remote Monitor RM-1000 is a device that provides remote management and control of the AIRDOLPHIN.
☛ Please note the following:
● Zephyr Corporation holds no responsibility for accidents or damages that may occur as a result of disregarding
the procedures and warnings described in this manual.
● Zephyr Corporation holds no responsibility for any attempts to modify the device.
● Zephyr Corporation holds no responsibility for accidents or damages that may occur as a result of improper
installation, use, or attempts to modify the device.
☛ The specifications are subject to change without prior notice.
☛ Refer to the owner’s manual for instructions on how to use the AIRDOLPHIN.
☛ The following information provided throughout his manual is not public information. It is provided just for
reference: current power generation displayed in watt (W), power generation displayed in kilo watts per power (kWh),
wind direction, stored power displayed in voltage (V), and temperature displayed in degree (℃).

Safety Instructions (Read and understand these entire instructions before proceeding.)

SAFETY WARNINGS AND SYMBOLS


To ensure proper use of the RM-1000, read this section carefully before installing, operating, or inspecting the Remote
Monitor RM-1000. Throughout this manual, safety information is divided into the following three categories: “Danger”,
“Warning”, and “Caution”. Note that failure to heed these signs could lead to severe consequences, depending on
circumstances. Observe all the instructions described as safety information as they convey important information.

This symbol indicates information that could result in death or server injury if the instruction is
ignored. It is used for information of a highly dangerous and/or urgent nature.

This symbol indicates information that could result in death or server injury if the instruction is
ignored.

This symbol indicates information that could result in server injury or property damage if the
instruction is ignored.

This symbol is intended to draw attention to a


This symbol indicates prohibited actions.
warning of danger, hazards, and the unexpected.

This symbol is intended to draw attention to This symbol indicates instructions that must
Danger/Warning/Caution information. be followed.

2
Stop operating the device immediately if you notice unexpected hazards or severe damages to the device and
connecting peripherals: In such events, contact your local dealer for immediate technical advice. Never try to disassemble
or modify the device on your own.

Do not disassemble the device: To do so may cause an electric shock accident.

In case of fire: Disconnect all peripherals such as wind turbines, a wind direction and speed measuring apparatus, and a
temperature measuring apparatus from the device if you detect an impending fire. In such events, contact your local dealer
or Zephyr Corporation for immediate technical advice. Never try to throw water on the fire. Use ABC powder fire
extinguishers to put out the fire

Do not connect the Remote Monitor RM-1000 to any non-designated peripherals or devices: To do so may cause
fire, an electric shock accident, or severe damages to the device and connecting peripherals.

Do not use the device on systems intended to maintain the public health and community infrastructure, such as life
critical medical devices, devices that may lead to personal injury, or computer systems that play an important role
in social and public systems: These devices may need to establish a multilateral system or install an emergency power
backup system, or require other special measures for proper maintenance and control.

Do not attempt to disassemble, repair, or modify the device: To do so may cause injury or accidents, or severe damages
to the device.

Do not use or store the device in places subject to extremely high or low-temperature, or high humidity. To do so
may cause fire accidents, deterioration, or severe or fatal damages to the device.

Do not use or store the device in places subject to direct sunlight or strong artificial light sources: To do so may cause
fire accidents, deterioration, or severe or fatal damages to the device.

Do not use or store the device in places subject to radiant heat: To do so may cause fire accidents, deterioration, or
severe or fatal damages to the device.

Do not use or store the device in places subject to high levels of vibration and/or shock: To do so may cause fire
accidents, deterioration, or severe or fatal damages to the device.
Do not use or store the device in close proximity to spark-generating devices: To do so may cause explosion accidents,
fire accidents, deterioration, or severe or fatal damages to the device.

Do not use or store the device in places subject to dust, salt, or water, or in close proximity to inflammable or
explosive gases: To do so may cause explosion accidents, fire accidents, deterioration, or severe or fatal damages to the
device.
Do not place a water-holding container, such as a vase, on top of the device: Water may be spilt and splashed onto
the device, or seep into the device, leading to fire or electrical shock accidents.

Do not step, stand, or sit on the device: To do so may cause personal injury or accidents.

Do not use the device outside of your country: Note that voltage regulations vary across the countries and using the
device elsewhere may cause smoke or fire. Contact your local dealer in advance if you wish to use the device outside of
your country.
Follow procedures and warnings described in this manual to operate the device: Disregarding the procedures and
warnings may cause accidents or damages.

Do not remove the cover of the device: Trained technicians only are allowed to do so. The removal of the cover on your
own may cause electrical shock accidents or burn.
*When you need repairs or replacement of parts, contact your local dealer.

3
GETTING STARTED

Contents of the Package

Check to see if all the required items are inside the RM-1000 package.

Item Quantity
1 RM-1000 1
2 DC-output adapter 1
3 AC/DC adapter 1
4 Multi Media Card (MMC) 1
5 Cable cover 2
6 Instruction Manual 1

Installing the RM-1000

Install the RM-1000 at the proper location.


You can mount it on a wall, prop it against the stand, or set it on a smooth, flat surface.
180 mm
To mount on a wall:
Fasten wood screws or the hooks to
Wall mount hooks secure the RM-1000 on a wall.

To prop on the stand:


Pull out the stand to prop the RM-1000
against it on a smooth, flat surface.

To set on a flat surface:


Stand Steady the RM-1000 using the
Anti-shake rubber stoppers anti-shake rubber stoppers and set it
(x 4 on the top, bottom, and sides) faceup on a smooth, flat surface.

The RM-1000 is designed for indoor use only. Installation outdoors may lead to severe
damage to it.

4
Connecting the RM-1000

You can connect the RM1000 to various systems. The following illustrations show examples of how you can connect it.

Example A: The AIRDOLPHIN Example B: Connecting multiple units


You can connect multiple RM-1000 units as
extended usage of examples A and B:
The multiple RM-1000 units show the same data.
(Note that you need to change some RM-1000
settings and that functions available are limited.)

This configuration is suitable for a place


requiring multiple monitoring locations such
as school.

Interfaces

< On the left side>


< Peripherals >
❺ ➊ Anemometer*1
❶ ❷ ❸ ➋ Thermometer*1
❹ ❻ ❸ Data communication cable (Data In)*1:
Step 1 See the information below on this page.
*1
Step 2 ❹ External timer (Ext Timer In) : Zephyr original
❺ DC-output adapter (DC Output): Provided with the device
❻ Power supply adapter: Provided with the device
< On the right side> ❼ Multi Media Card (MMC)*1:
Commercially available (with memory of up to 1 GB)
*1
❽ Inverter control cable (Inverter Ctrl) : (for the Japanese market only)
*1*3
❾ RS-485 cable : Commercially available
➓ LAN cable*1*2:
➑ ➒ ➓ Commercially available (CAT-5 or above recommended*4)

Step 3

Do not connect the Remote Monitor RM-1000 to any non-designated peripherals or devices.
To do so may cause severe damages to the device and connecting peripherals.

If an Multi Media Card that you are using exceeds 1 GB, RM-1000 data cannot be saved on
that card.

*1: Available as an option. Contact your local dealer for purchase.


2
*: Used to connect the device to a PC.
CAT-5, short for Category 5, is a category of twisted pair cabling systems in terms of data rates.
(Windows Vista is not supported.)
3
*: Used to serially connect multiple RM-1000 units.
STP (shielded twisted pair) cabling (1.25 mm x 2 wiring) recommended. 5
Connecting Peripherals

Step 1: Data communication cable


To connect the AIRDOLPHIN:
Plug the cable connecting with the AIRDOLPHIN firmly into the ➌ Data In (RS-485) plus and minus
terminals. Do not use the C terminal.
To connect multiple RM-1000:
Connect the Data Out (RS-485) terminal of the RM-1000 to the Data In (RS-485) terminal of the second
RM-1000 using a RS-485 cable. Connect multiple units in the same manner. When the connection is
completed, set the RM-1000 menu “112” to “0” and menu”122” to “2” for all units except for the last one.
Use STP (shielded twisted pair) cabling (1.25 mm x 2 wiring) to serially connect multiple units.

- Make sure to connect plus and minus terminals correctly. Otherwise, damage may be
inflicted on the RM-1000 and connecting peripherals.
- Do not use the Ⓒ terminal.

Step 2: AC/DC adapter (included as part of the RM-1000 package)


Plug the AC/DC adapter into the ➏ Power terminal on the left side of the RM-1000, and plug the end of the AC/DC
adapter into your national grid (AC 100V~240V). Please prepare an appropriate outlet adapter compliant with electric
utility regulations in your country.

Step 3: Multi Media Card (MMC)


Insert the MMC into the ➐ MMC slot until it clicks into the locked position.

Step 4: Check to see if the MMC indicator


lights steadily.

Step 5: Check to see if the F3 switch is set


to ON.

Step 4: MMC indicator


Check to see if the MMC is inserted properly in the MMC slot. When the MMC indicator lights steady red, the MMC is
inserted correctly.

Step 5: Monitor backlight


Check to see if the F3 switch is set to the I position (ON).

6
Step 6: Cable covers (included as part of the RM-1000 package)
Put the cable covers on both sides of the RM-1000. Pull off the cutoff sections in a direction toward the cable pulling
direction.

Back of the RM-1000 Front side of the RM-1000 Install the covers so the cutoff
The cutoff sections can be
sections are placed on the back
manually pulled off.
of the RM-1000.

Step6: Secure the cable pulling section and put the cable covers.

7
DISPLAYS AND FUNCTIONS
Let’s use the RM-1000. It displays such information as generated wind power, CO2 reduction amount, wind direction and
speed, and temperature. The displayed data can be saved on the Multi Media Card (MMC).




➊ ➌
➐ ➍

F1 F2 F3 F4 F5

Wind power generated: Display windows ① through ④


①Current (momentary): Value displayed in W (watt)
②Today’s total: Value displayed in Wh
③This month’s total: Value displayed in kWh
④Grand total: Value displayed in kWh
☞ When you press the F1 button with the F3 switch set to the O position (OFF), ② displays values of
yesterday’s total power, ③ displays values of last month’s total power, and ④ displays values of the
grand total generated up to the present.

① and ② display five-digit figures. When they display five-digit figures, the X10 indicator lights up.

Wind direction: △ indicator window ⑤ 1: North


The lighted △ indicator shows the current (momentary) wind direction. 8: Northwest 2: Northeast
☞ When there is no wind, the △ indicator does not light.

Wind speed: Display window ⑥ 7: West 3: East


The display window shows the current (momentary) wind speed.
⑥Wind speed: Value up to one decimal place 4: Southeast
6: Southwest
5: South
Today’s maximum wind speed/average speed: F1 button
When the F1 button is pressed:
⑥Today’s maximum wind speed: m/s
①Time of the maximum wind speed: e.g. 1234 = 12:34
②Today’s average wind speed: e.g. 0123 = 12.3 m/s
③This month’s average wind speed: e.g. 0035 = 3.5 m/s
④Annual average wind speed: e.g. 0032 = 3.2 m/s 8
CO
- 2 reduction amount: F3 switch (Turn off monitor backlight)
When you set the F3 switch to the O position (OFF), the monitor back light turns off and the following
will be displayed for approximately 5 to 10 seconds.
②Today’s CO2 reduction amount: Value in grams (g)
③This month’s CO2 reduction amount: Value in kilo grams (kg)
④Grand total CO2 reduction amount: Value in kilo grams (kg)

Output voltage of AIRDOLPHIN(Battery, Capacitor voltage): F2 button


When you press the F2 button, the voltage will be displayed.
⑥Voltage: Value displayed in 0.1 V resolution.

Temperature: F1 + F2 buttons (press together)


When you press the F1 and F2 buttons together for two seconds, the temperature will be displayed.
⑥Temperature: Value in ℃, in the –99 to –10 or –9.9 to +99.9 range.
☞ When the temperature is below – 10 degrees, figures below decimal point are not displayed.
☞ When the sensor is attached to the battery, the actual temperature of the battery will be displayed.

Operation mode of the AIRDOLPHIN: ⑦ (Three-color LED indicator)


The indicator displays the operation mode of the AIRDOLPHIN.
The lighting patterns are identical to those of the AIRDOLPHIN indicator. Please refer to the AIRDOLPHIN’s
Instruction manual for more details.

Switching the operation mode of the AIRDOLPHIN: F4 and F5 switches

F4 switch: Switch between Normal and Soft operation modes


Keep the switch in the Normal position for regular operations. Switch to Soft when you want to lower the rpm of
the AIRDOLPHIN, which keeps running in the Soft mode until the F4 switch is turned back to Normal.
- During Soft mode operation, the amount of power output and RPM will be limited compared to Normal mode
operation.
- The Power-Assist function of the AIRDOLPHIN operates during Soft mode operation.
- It will take several minutes until Normal mode operation re-starts after you switch to Normal mode operation.

F5 switch: Switch Operate/StopAIRDOLPHIN


Keep the switch in the Operate position for regular operations. The AIRDOLPHIN runs in either the Normal or
Soft mode based on the position of the F4 switch. Switch to Stop for maintenance purposes. The AIRDOLPHIN
keeps stopping until the F5 switch is turned back to Operate.

- The F5 switch has a higher set priority than the F4 switch.


- In the Stop mode, the rotor of the AIRDOLPHIN may spin when there is a strong, gusty wind.
(The braking system operates properly.)
- It will take several minutes until the AIRDOLPHIN resumes operation after the F5 switch is turned back to
Operate.

Multi Media Card (MMC) Indicator:⑧ + Display window ①


- When the MMC is inserted properly in the slot: The Indicator ⑧ lights.
- When the MMC is not inserted properly in the slot: The Indicator ⑧ does not light.
- When data is being saved on the MMC: The light blinks.
- When an error occurs: An error message will be displayed in ①. Please refer to page 20.
To remove the card, press the MMC Remove key on the right side of the RM-1000
and wait until the indicator light goes off. Otherwise, damage may be inflicted on
the RM-1000.
9
CHANGING THE RM-1000 SETTINGS
This section describes procedures to use the functions.
Step 1: To set date and time
3. Set the year, month, day, hour, and minutes.
S1: Press to make the currently flashing value go up
S2: Press to make the currently flashing value go down
S3: Press to go to the next data entry
2. Confirm ‘rtc’ display. S4: Press to go back to the last data entry

Right side

4. Set the F3 switch to the O position (OFF).

1. Press the F1 and S1 buttons together.

1. Press the F1 button on the front and the S1 button on the right side together for two seconds.
2. The current power window displays “rtc” to indicate (real time clock).
3. Using the S1 - S4 buttons, set the date and time in the order of the year, month, day, hour, and minutes.
4. When completed, set the F3 switch to the O position (OFF).
5. Turn the F3 switch back to the I position (ON).

Step 2: Other settings


2. Confirm display ‘U2’. 4. Confirm that the window 5. Enter the settings.
displays the correct device S1: Press to make the currently flashing value go up
menu number. S2: Press to make the currently flashing value go down

Right side

6. Turn the F3 switch to the O position (OFF).

1. Press the F1 and S2 buttons together.

3. Choose the RM-1000 menu.


F1: Press to go to the next RM-1000 menu
F2: Press to go back to the previous RM-1000 menu

1. Press the F1 button on the front and the S2 button on the right side together for two seconds.
2. The current power window displays “U2”.
3. Using the F1 and F2 buttons, choose the menu that you want to change.
4. Confirm that the Power window indicates the correct RM-1000 menu number.
5. Enter the settings.
6. When completed, set the F3 switch to the O position (OFF).
7. Turn the F3 switch back to the I position (ON).

You can change or reset the following RM-1000 menus. Please press F1 button on the front and S2 button on the right
10
side together for two seconds.

Factory
Menu Number Descriptions Configuration Notes
defaults
The grand total for the AIRDOLPHIN, which is
106 Reset power total. (day/month/grand total) [1]: Reset 0 saved to the AIRDOLPHIN memory, is always
displayed in the Total Power display window.
1. Reset Total
*Reset power total using Menu 106 after the
127 Offset grand total in kWh. 0 - 9999 0
offset.
Set the upper limit of analog output in percent
108 (100%=3Vdc) based on the rpm of the 0 - 100 100
The output range should be within 0 to 3Vdc.
AIRDOLPHIN.
Be sure to set a higher value for Menu 108 than for
Set the lower limit of analog output in percent
2. Analog Menu 109.
1 109 (0%=0Vdc) based on the rpm of the 0 - 100 0
Output*
AIRDOLPHIN.
(See page 12.)
Set the upper limit of the rpm of the
110 0 - 9999 700 Set the upper limit for one of the menus. If you set
AIRDOLPHIN.
the upper limit for both menus, Menu 111 has a
Set the upper limit of the generated power in
111 0 - 9999 200 higher set priority.
watts.
When serially connecting multiple units, set [0] for
2
3. Terminator* Set the terminator in RS-485 serial [0]: OFF all connecting units except for the end unit.
112 1
(See page 12.) communications. [1]: ON *After the setting, you need to pull off the AC/DC
adapter of RM-1000.
[1]: 1 min.
The shorter the interval, the larger the saved data.
[5]: 5 min.
4. Save Data to Set the interval to save the “AVERAGE” data * If you specify [0], data is saved every second.
113 [10]: 10 min. 10
MMC on the Multi Media Card (MMC). Saved data will be quite huge. It is recommended
[15]: 15 min.
that you not specify [0].
[30]: 30 min.
Set the time to activate the Soft mode, in the
114 3 0000
24-hour notation* .
0000 -
Set the time to deactivate the Soft mode, in the If you enter ’2400”, the AIRDOLPHIN keeps
115 3 2359/2400 0000
5. Timer Setting 24-hour notation* . operating in the Soft mode throughout the day.
(See page 12.) Set the time to activate the Stop mode, in the
116 3 0000
24-hour notation* .
0000 -
Set the time to deactivate the Stop mode, in the If you enter ’2400”, the Stop mode is kept active
117 3 2359/2400 0000
24-hour notation* . throughout the day.
Set the time to start analog output, in the If “00:00” is set for Menus 118 and 119, the timer
118 3 0000
6. Set Analog 24-hour notation* . 0000 - setting has no effect.
Output Timer Set the time to stop analog output, in the 2359/2400 If you enter ‘2400’, analog output continues
119 3 0000
24-hour notation* . throughout the day.
Set the time to start operation, in the 24-hour If “00:00” is set for Menus 120 and 121, the timer
120 0000 - 2359 0000
notation. setting has no effect.
7.Set Inverter
Timer Set the time to stop operation, in the 24-hour 0000 - If you enter ‘2400’, the inverter runs throughout the
121 2400
(For Japanese notation. 2359/2400 day if all operating conditions are met.
market only)
Set timer settings specified in Menus 120 and [0]: OR
123 0
121 to work with an external timer. [1]: AND

8. [0][1][4]~[7] is not available, you must not use.


Set the communication mode between [2]: RS-485
Communication 122 3 *After the setting, you need to pull off the AC/DC
RM-1000 and your PC. [3]: LAN
mode adapter of RM-1000.
*Battery life could be shorter if the factory
Set the battery voltage in 0.1 V increments to default is changed.
9. Battery 124 26.0 - 29.9 27.0
resume inverter output. Menu 124 becomes effective when the battery
Voltage Range
voltage exceeds the specified value for more than
for Inverter
30 seconds.
(For Japanese
Set the battery voltage in 0.1 V increments to Menu 125 becomes effective when the battery
market only) 125 20.0 - 25.0 24.0
stop inverter output. voltage drops below the specified value for more
than 30 seconds
10. CO2
Set the CO2 reduction ratio in grams based on
Reduction ratio 126 4 0 - 9999 360 See page 12 for more information.
your local power company’s data* .
(See page 12.)
11. Reset Wind
Reset all data relating to the wind speed and
Speed and 143 [1]: Reset 0
direction.
Direction

11
*1: Analog output (to synchronize with the rpm of the AIRDOLPHIN)

(Analog output: Vdc)

Factory default
Max.: 3Vdc

Example Example

Output 2.7Vdc (#108=90%)


Ⓑ RPM 500rpm (#110=500)

Output 1.2Vdc (#109=40%)
Ⓐ RPM 0rpm(fixed)

(Revolution per minute of the


Min.: 0Vdc/0rpm 700rpm AIRDOLPHIN)

*2: Terminator
The termination resistor is inside of RM-1000.It is possible to select the termination ON or OFF. The termination resistor
should be connected to the RM-1000 at the end of the serial connection. It prevents signal reflection, which is caused by the
impedance mismatch. Signal reflection causes signal distortion, which in turn leads to communication errors.

* 3: Timer settings for the AIRDOLPHIN


You can set the AIRDOLPHIN to operate or stop at preset time periods, in the 24-hour notation. For instance, you can set
so that the AIRDOLPHIN operates from 6:00 to 22:00 and stops from 22:00 to 6:00.

Example

6:00 12:00 22:00

Stop Operation Stop

*4: CO2 reduction ratio


This is the amount of CO2 emissions per 1kWh of power generation determined by your local power company. For more
details, please refer to the information provided by your local power company. For example, Tokyo Electric Power
(Japan) sets 425g CO2/1kWh as the ratio for CO2 reduction in 2007. This value changes every year.

12
OPERATING FROM YOUR PC

You can use the web server function available with the RM-1000 (ZephyrWeb-1000 hereafter) for remote management and
control of the AIRDOLPHIN from your PC.

Preparations (Basic)

Step 1: Check the following system requirements for your PC.


Item Requirements
RM-1000
IP address 192.168.127.200 (factory default)
Network settings
Subnet mask 255.255.255.0 (factory default)
PC
Operating System Microsoft® Windows® XP Version 2002 SP2 or later
CPU Intel® Pentium® 4 2.80 GHz
Memory 1.0 GB or greater
Browser Internet Explorer® version 6 or later
Java software Java Runtime Environment (JRE) version 1.6.0_02 or later

Step 2: Install the Java software on your PC.


TO INSTALL JAVA SOFTWARE:
1. Launch the Internet.
2. Access the Java web site (http://www.java.com/en/).
3. Click “Free Java Download”.
4. Click “Install”.
The download will start. ”

Step 3: Configure your PC’s network settings as instructed below.


This is required to use your PC on the same network where the RM-1000 is running.
☞ This step describes the Microsoft® Windows® XP procedure.
1. Click ‘Start’, go to ‘Settings’ and then ‘Control Panel’.
2. Click ‘Network Connections’.
3. Click ‘Local Area Connection’ and choose ‘Properties’ from the File menu, or right-click ‘Properties’.
4. Choose ‘Internet Protocol [TCP/IP]’ and click ‘Properties’.
5. Click on the ‘General’ tab. At ‘Specify an IP Address’ or ‘Use the following IP address’, enter the IP address. Under
‘Subnet Mask’, enter the subnet mask.
IP address: 192.168.127.XXX (The example screen shows the IP address 192.168.127.1)
Subnet mask: 255.255.255.0
☞ Enter any value from 1 to 255
in ‘XXX’. Do not enter “200”.
It returns an error.
6. Click ‘OK’.
The setup procedure is completed.

When you change the IP address of your PC as instructed in step 3, you cannot connect to
your network or the Internet. To avoid this, change the default IP configuration of the
RM-1000 in step 5 described on page 14.

13
Step 4: Connect your PC to the RM-1000.
Connect the LAN terminal of your PC to the LAN terminal on the right side of the RM-1000 using a commercially
available LAN cable.
There are two types of cables available:
Straight cable: Used to connect your PC to the RM-1000 via a network hub.
Cross cable: Used to connect your PC directly to the RM-1000.
Right side of the RM-1000

LAN terminal
When using a straight cable: Connect the LAN terminal to
the hub’s LAN terminal.
When using a cross cable: Connect the LAN terminal to
the PC’s LAN terminal.

Preparations (Advanced 1): To use the RM-1000 on your local network

Repeat steps 1 through 4. In step 5, change the factory default IP configuration of the RM-1000 to use the
RM-1000 on your local network.

Step 5: Change the default IP configuration of the RM-1000 as instructed below.


1. Launch the Internet Explorer.
2. Enter [http://192.168.127.200] in the address bar and press the Enter key.
3. The dialog box appears prompting you to enter the user name and password. Click ‘OK’ without entering anything
at all.
4. The WiPort main window appears. Click ‘Network’ from the menu displayed on the left column.
5. Choose ‘Use the following IP configuration’. Enter your private IP address (local IP address) for ‘IP Address’ and
‘local subnet mask’ for Subnet Mask.
6. Confirm the entered values and click ‘OK’.
7. Click ‘Apply Settings’ after you have confirmed that the ‘Done!’ message appears next to ‘OK’ on the screen.
8. A status bar appears, indicating your changes are being saved. The screen returns to the WiPort main window in
seconds. The setup procedure is complete.
* Your changes were saved even if the screen does not return to the WiPort main window, if several seconds have
already passed.

192.168.127.200 に接続 Network

Click ‘OK’ without


192.168.127.200 へようこそ entering anything

Apply Setting

Enter values for IP


Address and Subnet Mask
and click ‘OK’

Confirm that the


‘Done!’ message
appears on the
screen and click 14
‘Apply Settings.’
Preparations (Advanced 2): To access the RM-1000 via the Internet using a router

Step 6: Set up a router.


☞ You can connect to the RM-1000 via the Internet for remote control and management and to have access to the
RM-1000 data. You first need to assign a private IP address to the RM-1000 and a global IP address to the router
that you are using to access the RM-1000 through address conversion by the Network Access Translation/IP
masquerade (NAT) function.

This section provides the minimum information on how to access the RM-1000 via a router.
Your choice of router or network configuration may require more setup. Check the router
specifications and ask your system administrator in advance.

You need to prepare a designated router, contract with an Internet service provider, and
obtain a global IP address in advance.

1. Refer to step 5 on page 14 to assign a private IP address to the RM-1000.


2. Access your router. Refer to the documentation that comes with the router for more information.
3. Assign your global IP address to the router. Refer to the documentation that comes with the router for more
information.
4. Set up ports in your router for Network Access Translation/IP masquerading (NAT).
① Open the port number 80 for HTTP to configure the private IP address assigned to the RM-1000.
② Open the port number 10001 for data transfer to configure the private IP address assigned to the RM-1000.

☞ The port number 80 is the default port number for HTTP in most cases. You can use a different port number.
☞ The port number 10001 is set as the default for the RM-1000. To change the port number, you need to change
both the router and RM-1000 port settings.

To change the default port number 10001 for the RM-1000:


1. Refer to step 5 on page 14 to open the WiPort.
2. Click ‘Channel 1’ from the menu displayed on the left column in the WiPort main window and enter your choice of
port number for ‘Local Port’ under ‘Endpoint Configuration’.
3. Confirm the entered value and click OK.
4. Click ‘Apply Settings’ after you have confirmed that the ‘Done!’ message appears next to ‘OK’ on the screen.

Connection

Change the default port number 10001.

15
Starting the ZephyrWeb-1000

Step 1: Launch the Internet Explorer on your PC.


☞ Be sure to use the Internet Explorer as your browser.

Step 2: Enter the URL in the address bar and hit Enter.
You can choose the display language between Japanese and English, and the screen format between standard 4:3 and
widescreen 16:9 aspect ratio.

When IP configuration is the default:


Japanese/standard 4:3 http://192.168.127.200/zw1000_jp.html
Japanese/widescreen 16:9 http://192.168.127.200/zw1000_jp_wide.html
English/standard 4:3 http:// 192.168.127.200/zw1000_en.html
English/widescreen 16:9 http:// 192.168.127.200/zw1000_en_wide.html
When the IP configuration has been changed to user-specified settings:
Japanese/standard 4:3 http:// XXX. XXX. XXX. XXX /zw1000_jp.html
Japanese/widescreen 16:9 http:// XXX. XXX. XXX. XXX /zw1000_jp_wide.html
English/standard 4:3 http:// XXX. XXX. XXX. XXX /zw1000_en.html
English/widescreen 16:9 http:// XXX. XXX. XXX. XXX /zw1000_en_wide.html

Step 3: Explorer user prompt dialog box


☞ The dialog box appears when you launch the ZephyrWeb-1000 for the first time.
Enter up to 30 characters for the name of the AIRDOLPHIN in the dialog box and click OK.

Step 4: Java Warning-Security dialog box


When using Java to open an application for the first time, a Warning – Security dialog box appears. Check ‘Always trust
content from this publisher’ and then click ‘Execute’.
The ZephyrWeb-1000 main window appears in the language and size specified.

Check the checkbox


and then click
‘Execute’.

Step 5: Specify the node address.


Click the ‘Node Address’ button on the lower right corner of the window. Enter the password and node address
and click ‘OK’. The password is [root], and the Node address is [23].

The ZephyrWeb-1000 starts displaying information in the window.

16
Click ‘Node Address’

Enter [root] for the password and


[23] for the node address and
click ‘OK’.

17
Using the ZephyrWeb-1000

Let’s use the ZephyrWeb-1000. You can view the following information in the ZephyrWeb-1000 window.

- Functions are basically the same with the RM-1000. (See pages 8 and 9.)
- There are no functional differences between the Japanese and English versions.


⑦ ②

① ④

⑬ ⑤


⑨ ⑩ ⑪
⑭ ⑮

⑯ ⑰ ⑱

Displays and Functions

① Sum of current (momentary) wind power and solar power *The solar power function is only for the Japanese
market.
② Current (momentary) wind power
③ Current (momentary) solar power *The solar power function is only for the Japanese market.
④ AIRDOLPHIN roter RPM
⑤ Output voltage of AIRDOLPHIN (voltage of the battery or capacitor included in the system.)
⑥ The lighted arrow points in the present (momentary) wind direction
⑦ Current (momentary) wind speed
⑧ Current (momentary) temperature (When the thermometer is not connected, the temperature inside of the
AIRDOLPHIN is displayed.)
⑨ Click to display today’s maximum wind speed and its time, today’s average wind speed, this month’s average
wind speed , annual average wind speed and today’s high and low temperatures in a new window.
⑩ Click to display today, yesterday, this month, last month and the grand total of generated power in a new
window.
⑪ Click to display the CO2 reduction amount in relative to the generated power in a new window.

18
⑫ Multi Media Card (MMC) activity indicator. It lights blue when the card is functioning properly and lights red
when an error occurs.
⑬ The operation mode of the Airdolphin is displayed with the three-color LED indicator.
⑭ Click to switch operation modes between Normal and Soft. Enter [root] for the password.
⑮ Click to switch operation modes between Operate and Stop. Enter [root] for the password.
You can switch operation modes of ⑭⑮ when the F4 switch of RM-1000 is set to
Normal and the F5 switch of RM-1000 is set to Operate. (Please refer to page 9.).
.

⑯ Enter the name of the AIRDOLPHIN.


⑰ Enter the CO2 reduction ratio. Enter [root] for the password.
⑱ Enter the node address. Enter [root] for the password.
Be sure to enter [23] for the node address. If you leave it blank or enter
different values, the ZephyrWeb-1000 may not function properly.
⑲ The name of the AIRDOLPHIN entered for ⑯ is displayed here.

⑳This area displays ten levels of rainbow in daylight corresponding to operating conditions (the rpm or
generated power) of the AIRDOLPHIN.

This feature synchronizes with the Analog Output function of the RM-1000.
Refer to the RM-1000 menus 108 –111 and 118 - 119 on page 11 for more
information.

⑧ ⑨ ⑩





② When RPM (or power) reaches 90 % or
① more of the preset upper limit explained
in menus 110 and 111 described on
page 11, the rainbow will reach the
maximum length.

Closing the ZephyrWeb-1000

The ZephyreWeb-1000 will automatically be closed when you close the Internet Explorer. To close the application, use one of
the following:

- Choose ‘Close’ from the File menu


- Click the Internet Explorer close button (X) on the upper-right corner of the browser window
- Click the close tab button (x) on the tab displaying the ZephyrWeb-1000. (Internet Explorer 7 only)
- Press the Alt and F4 keys on the keyboard together
- Press the Ctrl, Alt, and Delete keys on the keyboard together to open Task Manager, choose Internet Explorer on
the Applications tab, and then click the ‘End Task’ button at the bottom of the window.

19
TROUBLESHOOTING

Is there something wrong with the RM-1000 or connecting peripherals?


RM-1000 Check this Reference page
Make sure that the AC power cord is plugged into the AC input. page 6
Indicators do not light
Check to see if the F3 switch is set to the O position (OFF). page 6
No display of the wind speed and Check to see if the anemometer is connected to the RM-1000.
direction Check to see if the cup at the bottom of the anemometer has fallen off.
Make sure that the plus and minus terminals of the data communication
page 5
cable are correctly plugged into the ‘Data In’ terminal on the RM-1000.
No display of generated power Is there enough wind? When there is no wind or near zero wind, the
AIRDOLPHIN will utilize the Power-Assist function.
Check to see if the F5 switch is set to Stop. page 9
Error: PERR You cannot save data to the Multi Media Card. Unlock anti-write protection.
Error: CERR The Multi Media Card is unformatted or broken. Replace it with a new one.
Check to see if the data communication cable is disconnected from the
Error: OERR page 5
‘Data In’ terminal on the RM-1000.
Check to see if the F5 switch is set to Stop. page 9
Check to see if the AIRDOLPHIN is kept stopped by the specified timer
page 11
The AIRDOLPHIN does not run setting.
Check on the battery voltage. When the voltage is below 20 V, the
Charge the battery.
AIRDOLPHIN is unable to start the Power-Assist function.
The AIRDOLPHIN’s three-color
LED indicator is alternately Check to see if the data communication cable is disconnected from the
page 5
flashing red, yellow, and then ‘Data In’ terminal.
green

ZephyrWeb Check this Reference page


Check to see if you have entered the correct URL in the address bar. page 13
Check to see if the LAN cable is disconnected from the RM-1000. page 14
The main window does not Check to see if the LAN cable is the correct one (cross or straight). page 14
appear at all Check to see if the power supply adapter is plugged in. page 5
Is the IP address of your PC correct? pages 13-15
Check to see if Java software is installed. page 13
Have you entered the node address? page 16
Check to see if the data communication cable is connected to the Data In
No display of data page 5
terminal.
(Windows can open)
Check on the display windows of the RM-1000. If not, refer to the above
information.
The operation mode cannot
Check to see if the operation mode of the RM-1000 is set to [Operate ] and
be switched to Normal, Soft, page 9
[Stop].
and Stop

If you have other problems or have questions, please contact your local dealer for immediate
technical advice.

20
Saving data on the multi media card (MMC)

Step 1: Create data files


Data files are updated on a monthly basis. If you turn off the RM-1000 or remove the Multi Media Card from the MMC slot
(before the scheduled update), an another data file is created. The number of files depends on how often you turn off the
RM-1000 or remove the card from the slot.

A file name example: RM0804XX ‘XX’ stands for the file number( in hexadecimal), which is automatically assigned in
order.

Step 2: Data formats to be saved on the card


Example
Zephyr's RM-1000 Data Log, Firmware version:V2366
DT|TM NA WS[m/s] WM[m/s] WD[deg] AT[dC] BV[V] RV[rpm] WP[W] WHPD[Wh] WHPM[Wh] WHPT[Wh] ST+EV SC
07/09/06|20:32:30 FF 02.6 16.0 15F 025.6 25.0 0209 00000000 00000011 00000011 00108084 0201 00 025.5
∼FT[dC] GT[dC] ER+SST DTY LGC
∼027.2 0000 0000 000142A1

① Zephyr's RM-1000 Data Log, Firmware version:V2366 : Device type and version
② DT|TM : yy/mm/dd|time : e.g. 08/04/01|01:23:45
③ NA : node address : e.g. 23 (in hexadecimal number) < It means 35 in decimal number.>
④ U[g-CO2/kWh] : CO2 point source [g] : e.g. 0.360 < It means 360 grams-CO2/kW.>
⑤ WP[W] : average wind power[W] : e.g. 00001234
⑥ WHPT[Wh] : total wind power[Wh] : e.g. 00123456
⑦ PP[W] : average photovoltaic power[W] : e.g. 00000200*
⑧ PHPT[Wh] : total photovoltaic power[W] : e.g. 00123456*
⑨ WD[deg] : wind direction [360 degrees] : e.g. 251 <This indicates west southwest. (north = 0 degree)>
⑩ WS[m/s] : average wind speed [m/s] : e.g. 12.3
⑪ WM[m/s] : maximum wind speed [m/s] : e.g. 25.6
⑫ RV[rpm] : average revolutions [rpm] : e.g. 1234
⑬ BV[V] : output (battery) voltage [V] : e.g. 25.6
⑭ AT[dC] : temperature [centigrade] : e.g. 024.5
* for the Japanese system only

Maintenance data
The data is intended for service. If trouble or the unexpected occurs, technicians at your local dealer or Zephyr Corporation use it for
troubleshooting.

①FT[dC] ②GT[dC] ③WDTY ④ST+EV ⑤SC ⑥ER+SST ⑦PV[V] ⑧PDTY ⑨P&MST ⑩LGC

Step 3: Using data


You can arrange the data saved on the Multi Media Card nice and neat by opening in Microsoft® Excel or other
spreadsheet applications.

21
Specifications

Product Remote Monitor


Name RM-1000
Dimensions (W x H x D) 330 x 152 x 48 mm
Weight (main unit) 820 g
Power Supplied from the power source adapter (100-240 V) or DC24V
When the LED is displayed: less than 3W (AC100V)/during analog
Power consumption
output: Max. 12W
Temperature 5 - 35 ℃
Operating conditions
Humidity 20 - 80 %
Features
Power output (4-digit display)
Momentary 0 - 9999 W
Today/yesterday 0 - 9999 Wh
Total This month/last month 0 - 9999 kWh
Grand total 0 - 9999 kWh
CO2 reduction amount (4-digit display)
Daily 0 - 9999 g
Total Monthly 0 - 9999 kg
Display LED Grand total 0 - 9999 kg
Output voltage (3-digit display) 0.0 - 99.9 V
Wind speed*1 (3-digit display)
Momentary 0.0 - 99.9 m/s
Maximum 0.0 - 99.9 m/s
Wind direction*1 8 directions
2 -99 ~ -10、-9.9 ~ +99.9 ℃
Temperature (battery* )
(When the temperature is below -10 degrees, figures below
(3-digit display)
decimal point are not displayed.)
AIRDOLPHIN operation
Operating condition Operate/Stop (F5)
Operation mode Normal/Soft (F4)
Panel switch
Output voltage display Tact switch (F2)
Maximum wind speed display Tact switch (F1)
Monitor backlight ON/OFF (F3)
AIRDOLPHIN data in One-touch connection terminal block
Serial connection of multiple RM-1000 units
RS-485 (2-wire, half duplex, distance: Max. 1,000 m)
(Data-OUT)
PC input/output
RJ-45 connector (10/100Base-T, distance : Max. 100 m)
Wired LAN*3
*A hub required when using a straight cable.
Analog output (DC-output synchronize with the rpm of the AIRDOLPHIN or generated power)
Terminals
RPM 0 - 700 rpm or over (*variable)
Output voltage DC 0 - 3V (*variable)
Output current Up - 0.5A (*An amplifier required for consumption of 0.5A or over)
Output bit rate 0.011 V/2.7 rpm
Anemometer input RJ11 connector
Thermometer input RJ11 connector
Inverter control RJ11 connector (available only for the Japanese market)
Data saving Multi media card (MMC), to be inserted into the slot.
Memory backup Built-in lithium battery for memory backup
Calendar/clock Built-in quartz calendar clock
Optional accessory Cross cable for wired LAN connections
*1: When the Zephyr AM-10 is connected
*2: When the Zephyr TH-5 orTH-10 is connected
*3: Designed for use with the ZephyrWeb ZW-1000 and ZephyrManager ZM-1000

22
Data file format FAT16
Memory capacity Max. 1GB (multi media card exceeding 1 GB cannot be used.)
Selectable from the following:
Data recording interval
Every second (instantaneous)/every 1 min./every 5 min./every 10 min./every 15 min.//every 30 min.
Every second (instantaneous): Approx.11MB/day (5.5 MB file x 2)
Every 1 min: Approx. 6MB/month
Data size per interval
Every 5 min: Approx. 1MB/month
Every 10 min: Approx. 600 kB/month

Dimensions

Cable cover

Maintenance and Inspection


Check the following and make sure:
- that the terminals of connecting peripherals are connected to the terminals of the RM-1000 correctly
- that the display windows on the RM-1000 panel display the information correctly
- that dust is not piled up on the surface of the RM-1000.
- that the power supply adapter is not exceptionally hot.
23
Hatsudai Center Bldg., Hatsudai 1-51-5, Shibuya-ku,
Zephyr Corporation Tokyo, Japan
Tel +81-3-3299-1910 Fax +81-3-3299-1977
URL http://www.zephyreco.co.jp
24