You are on page 1of 5

NINGBO SUN RISE ELECTRONIC TECHNOLOGY CO.,LTD.

SPECIFICATION

NO.515 Longjiaoshan Road , Beilun, Ningbo , Zhejiang , P.R.C


TEL: 86-574-86868531 FAX: 86-574-86868530

/ PV Wire and Cable

/SPEC. : PV wire 12AWG 90 600V & PV1-F 1x4.0mm²

/ ITEM NO. 3072000003

/ REVISION: 01

/ TOTAL PAGES: 4

PREPARED BY: CHECKED BY APPROVED BY


Revision:01 page 1/4

Halogen-free cable for PV photovoltaic equipment

/ Type

TUV: PV1-F 1x4.0mm²

/ Product Standard

TUV 2 PFG 1169/08.2007

/ Construction

(IEC 60228 Class 5) 56/0.30mm


Conductor Tinned stranded copper wire(IEC 60228 Class 5) 56/0.30mm

Insulation Irradiation crosslinked lszh flame retardant polyolefin Color: black

4.3± 0.1 mm
ID
:
Jacket Irradiation crosslinked lszh flame retardant polyolefin Color: black

6.0± 0.2 mm
O.D.

TÜV 2 PfG 1169 PV1-F 1X4.0mm2 R50241991


Marking
Maximum resistance of conductor at 20℃ ≦5.09 Ω/km

lnsulation volume resistance at 20℃ ≧1014Ω•cm

lnsulation volume resistance at 90℃ ≧1011Ω•cm

Surface resistance of jacket ≧109Ω

AC 6.5KV or DC15KV 5mins, No break


Voltage test of finished cable AC 6.5KV orDC15KV 5mins, No break

900V,240h (85 3% Nacl),


DC Voltage test of insulation 900V,240h (85℃,3% Nacl), No break

Unaged
≧125%
Elongation of insulation
≧10.3 Mpa
Tensile strength of insulation

Aged

After aging elongation of insulation 70% min.of the value before aging

After aging tensile strength of insulation 70% min.of the value before aging

Unaged
≧125%
Elongation of jacket
≧10.3 Mpa
Tensile strength of jacket

Aged

After aging elongation of jacket 70% min.of the value before aging

After aging tensile strength of jacket 70% min.of the value before aging

≦2%
Shrinkage resistant of jacket
EN60811-2-1
Acid and alkali resistant

EN50396
Ozone resistance

HD 605/A1
UV resistant

2PfG 1169/08.2007 appendix F


Dynamic penetrate force

Winding at low temperature No crack

Impact at low temperature No crack

IEC60332-1 & UL FT1


Fire performance

PH≧4.3, HCL≦0.5%, HBr≦0.5%, F≦0.1%


Halogen free

EN60216-1,EN60216-2,TI120
Thermal endurance Test
Application

Application Suited for connecting photovoltaic system components


inside and outside of buildings and equipment
600/1000V AC , 1000/1800V DC
Rated voltage

–40℃〜90℃
Working temperature

120℃
Max.conductor temperature

200℃ 5S
Short circuit temperature

5 D
Bending radius

Service life >25years

Approval
TÜV 2 PfG 1169/08.2007 PV1-F

You might also like