You are on page 1of 1

A B C D E F NOTES:-

1. ALL DIMENSION ARE IN FEET & INCHES.

2. WORK TO FIGURED DIMENSION ONLY.

1 3. GRADE OF CONCRETE M25

4. GRADE OF STEEL Fe 500

5. CLEAR COVER TO REINFORCEMENT


FOR SLAB & BEAM-1"

Y8@7"c/c
Y8@7"c/c
6. READ WITH ARCHITECTURAL AND MEP
DRAWINGS.

7. ANY DISCREPENCY IN THE DRAWING SHALL BE


Y8@7"c/c Y8@8"c/c BROUGHT TO NOTICE OF CONSULTANTS BEFORE
EXECUTION.

2
Y8@7"c/c

Y8@6"c/c

Y8@7"c/c Y8@6"c/c

3
Y8@8"c/c

Y8@7"c/c

GOOD FOR CONSTRUCTION


Y8@7"c/c Y8@8"c/c
SIGN.............................................

DRAWN : SKU SCALE : NTS


4
DESIGNED : HARSHA DATE : 20/01/2021
CHECKED : ANAND
Y8@7"c/c

5 DRAWING NO: HJ / HY / UK / ST / 007

REV NO : R0
STAIRCASE
Y8@7"c/c
. REINF.
Y10@4"c/c. PROJECT :
6
Y8@8"c/c S
PROPOSED RESIDENCE FOR
Y8@8"c/c

E W
Mr.D UDAY KUMAR
N

(GROUND FLOOR ROOF SLAB BOTTOM REINFORCEMENT DETAILS)


GROUND FLOOR ROOF SLAB
(DISTRIBUTION FOR BOTTOM REINFORCEMENT Y8@10"c/c ) BOTTOM REINFORCEMENT DETAILS
DISTRIBUTION BARS
TOP REINFORCEMENT
L2 X0.1 Y8 @ 10"c/c L2 X0.3 L1 X0.3 L1 X0.1

BOT. REINFORCEMENT
Z:\Server\LOGO.jpg
L2 L1
EDGE BEAM INTERMEDIATE BEAM EDGE BEAM

TYP SLAB DETAIL