TEST CERTIFICATE
Customer : M/S. PROMOTORES ELECTRICOS S.A
Our Ref. : Inv. / Order No. BCA-11728 Dated : 06-09-2017
Item : PROMELSA 300 mm2 -1/2" Tined Copper Terminal.
Qty. : 800 Nos.

A. Chemical composition (IS 191) for Cu :

Composition Required Value Observed Value


I. Copper content (as Cu) ≥ 99.90 % 99.96 %
II. Bismuth content (as Bi) ≤ 0.001 % 0.00017 %
III. Lead content (as Pb) ≤ 0.005 % 0.0008 %
IV. Total impurities ≤ 0.030 % 0.03 %

B. Mechanical Test (IS 2501) for Cu Tube :

I. Tensile test ≥ 205 Mpa 245.5 MPa


II. Hardness (on barrel) ≤ 60 HV5 54.4 HV5
III. *Flattening Test 180° Ok, not cracked

C. Electrical Test (IS 191) for Cu :


I. Conductivity test (on Palm) 97 % IACS Min. 98.8 % IACS
2
II. Resistivity test @ 20ºC ≤ 0.01777 Ω mm /m 0.0174504 Ω mm2/m

D.  Surface Treatment (IS 1359) :

I. Tin coating thickness ≥5 µm 5.4 To 6.2 µm

E.  Dimension Test :

I. All dimensions checked & found within tolerance.

F.  Visual Observation :

I. Uniform surface finish found on product & surface found burrs free.

Conclusion:
The above product meets all required specification of Standard.

…………………………………..
For Quality Assurance Dept.
Notes:
1. *Sample tested after annealing.
2. Copper purity is as per Spectro analysis test.
3. The resistivity value calculated from conductivity result.
4. The specified values are the values as per reference standard or customer requirement.
5. The test results relate only to the sample tested.
6. Purity, Conductivity, Hardness & dimension test done on lot samples and this material belong to the same